English
Related papers

Related papers: Scanning SQUID microscopy in a cryogen-free diluti…

200 papers

Scanning Superconducting QUantum Interference Device (SQUID) microscopy is a powerful tool for imaging local magnetic properties of materials and devices, but it requires a low-vibration cryogenic environment, traditionally achieved by…

Superconductivity · Physics 2019-07-04 Logan Bishop-Van Horn , Zheng Cui , John R. Kirtley , Kathryn A. Moler

The scanning superconducting quantum interference device (SQUID) fabricated on the tip of a sharp quartz pipette (SQUID-on-tip) has emerged as a versatile tool for nanoscale imaging of magnetic, thermal, and transport properties of…

We report on a scanned superconducting quantum interference device (SQUID) microscope operating in a cryogen-free cryostat, with the capability of up to forty RF connections with 20 GHz bandwidth to a device under test. The system utilizes…

Superconductivity · Physics 2025-09-10 Ian W. Haygood , Bochao Xu , John Biesecker , Michael L. Schneider

We present a new generation of a scanning MicroSQUID microscope operating in an inverted dilution refrigerator. The MicroSQUIDs have a size of 1.21$ \ \mu$m\textsuperscript{2} and a magnetic flux sensitivity of 120 $\mu\Phi_{0} /…

We report on our design of a scanning gate microscope housed in a cryogen-free dilution refrigerator with a base temperature of 15 mK. The recent increase in efficiency of pulse tube cryocoolers has made cryogen-free systems popular in…

Instrumentation and Detectors · Physics 2014-09-09 Matthew Pelliccione , Adam Sciambi , John Bartel , Andrew Keller , David Goldhaber-Gordon

Superconducting microcalorimeters, such as superconducting transition-edge sensors and magnetic microcalorimeters, have emerged as state-of-the-art detectors for X-ray emission spectroscopy by combining near-unity quantum efficiency with…

Instrumentation and Detectors · Physics 2026-04-29 Jodok Zeuner , Constantin Schuster , Sebastian Kempf

Low-temperature scanning probe microscopes (SPMs) are critical for the study of quantum materials and quantum information science. Due to the rising costs of helium, cryogen-free cryostats have become increasingly desirable. However, they…

We present the design and construction of a SQUID-based magnetometer for operation down to temperatures T = 10 mK, while retaining the compatibility with the sample holders typically used in commercial SQUID magnetometers. The system is…

Instrumentation and Detectors · Physics 2007-05-23 A. Morello , W. G. J. Angenent , G. Frossati , L. J. de Jongh

We have designed and built a scanning tunneling microscope (STM) setup for operation at millikelvin temperatures in ultra high vacuum. A compact cryostat with an integrated dilution refrigerator has been built, that allows measurements at a…

Instrumentation and Detectors · Physics 2018-12-05 Timofey Balashov , Michael Meyer , Wulf Wulfhekel

We describe a new type of scanning probe microscope based on a superconducting quantum interference device (SQUID) that resides on the apex of a sharp tip. The SQUID-on-tip is glued to a quartz tuning fork which allows scanning at a…

Superconductivity · Physics 2013-08-13 A. Finkler , D. Vasyukov , Y. Segev , L. Ne'eman , E. O. Lachman , M. L. Rappaport , Y. Myasoedov , E. Zeldov , M. E. Huber

Superconducting quantum interference devices (SQUIDs) are exceptionally sensitive magnetometers capable of detecting weak magnetic fields. Miniaturizing these devices and integrating them onto scanning probes enables high-resolution imaging…

Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the…

Cryogenic microcalorimeters are key tools for high-resolution X-ray spectroscopy due to their excellent energy resolution and quantum efficiency close to 100%. Multiple types of microcalorimeters exist, some of which have already proven…

Instrumentation and Detectors · Physics 2023-10-26 Constantin Schuster , Sebastian Kempf

Cryogenic microcalorimeters are outstanding tools for X-ray spectroscopy due to their unique combination of excellent energy resolution and close to 100% detection efficiency. While well-established microcalorimeter concepts have already…

Instrumentation and Detectors · Physics 2023-11-15 Constantin Schuster , Sebastian Kempf

We report on state-of-the-art scanning probe microscopy measurements performed in a pulse tube based top-loading closed-cycle cryostat with a base temperature of 4 K and a 9 T magnet. We decoupled the sample space from the mechanical and…

Scanning superconducting quantum interference device microscopy (sSQUID) is currently one of the most effective methods for direct and sensitive magnetic flux imaging on the mesoscopic scale. A SQUID-on-chip design allows integration of…

Mesoscale and Nanoscale Physics · Physics 2021-12-10 Y. P. Pan , J. J. Zhu , Y. Feng , Y. S. Lin , H. B. Wang , X. Y. Liu , H. Jin , Z. Wang , L. Chen , Y. H. Wang

We describe the construction and performance of a scanning tunneling microscope (STM) capable of taking maps of the tunneling density of states with sub-atomic spatial resolution at dilution refrigerator temperatures and high (14 T)…

Instrumentation and Detectors · Physics 2013-10-04 Shashank Misra , Brian B. Zhou , Ilya K. Drozdov , Jungpil Seo , Andras Gyenis , Simon C. J. Kingsley , Howard Jones , Ali Yazdani

We present the design and implementation of a mechanical low-pass filter vibration isolation used to reduce the vibrational noise in a cryogen-free dilution refrigerator operated at 10 mK, intended for scanning probe techniques. We discuss…

A novel scanning probe technique is presented: Scanning microSQUID Force microscopy (SSFM). The instrument features independent topographic and magnetic imaging. The SSFM operates in a dilution refrigerator in cryogenic vacuum. Sample and…

Superconductivity · Physics 2007-05-23 C. Veauvy , D. Mailly , K. Hasselbach

We report the implementation of a dilution-refrigerator-based scanning microwave impedance microscope (MIM) with a base temperature of ~ 100 mK. The vibration noise of our apparatus with tuning-fork feedback control is as low as 1 nm. Using…

Mesoscale and Nanoscale Physics · Physics 2023-05-17 Zhanzhi Jiang , Su Kong Chong , Peng Zhang , Peng Deng , Shizai Chu , Shahin Jahanbani , Kang Lung Wang , Keji Lai
‹ Prev 1 2 3 10 Next ›