Related papers: Complex impedance of TESs under AC bias using FDM …
We describe the design and measurement of feedhorn-coupled, transition-edge sensor (TES) polarimeters with two passbands centered at 220 GHz and 280 GHz, intended for observations of the cosmic microwave background. Each pixel couples…
The performance of an electroluminescence (EL) Time Projection Chamber (TPC) with a multi avalanche photodiode (APD) readout was studied in pure xenon at 3.8 bar. Intercalibration and reconstruction methods were developed and applied to the…
Several hundreds of thousands of eclipsing binaries (EBs) are expected to be detected in the Transiting Exoplanet Survey Satellite (TESS) full frame images (FFIs). This represents a significant increase in the number of EBs available for…
For astronomical instruments, accurate knowledge of the optical pointing and coupling are essential to characterize the alignment and performance of (sub-)systems prior to integration and deployment. Ideally, this requires the phase…
Understanding the magnetic field sensitivity of Transition Edge Sensors (TESs) is vital in optimising the configuration of any magnetic shielding as well as the design of the TESs themselves. An experimental system has been developed to…
We report on the development of multi-absorber transition edge sensors (TESs), referred to as hydras. A hydra consists of multiple x-ray absorbers each with a different thermal conductance to a TES. Position information is encoded in the…
We suggest a new type of an ultrasensitive detector of electromagnetic fields exploiting the giant thermoelectric effect recently found in superconductor/ferromagnet hybrid structures. Compared to other types of superconducting detectors…
Our paper presents a non-destructive thermal transient measurement method that is able to reveal differences even in the micron size range of MEMS structures. Devices of the same design can have differences in their sacrificial layers as…
The EDELWEISS collaboration aims for direct detection of light dark matter using germanium cryogenic detectors with low threshold phonon sensor technologies and efficient charge readout designs. We describe here the development of Ge…
Monolithic Active Pixel Sensors (MAPS) in advanced CMOS imaging technologies are key to next-generation tracking systems for high-energy physics, where radiation hardness and precise vertex reconstruction are essential. As part of the ALICE…
We have studied the origin of excess noise in superconducting transition-edge sensors (TES) with several different detector designs. We show that most of the observed noise and complex impedance features can be explained by a thermal model…
Accurate thermal modeling of Terminal Test Masses (TTMs) is crucial for optimizing the sensitivity of gravitational wave interferometers like Virgo. In fact, in such gravitational wave detectors even minimal laser power absorption can…
Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the feasibility of being multiplexed into large arrays. In this…
We are developing multi-chroic antenna-coupled TES detectors for CMB polarimetry. Multi-chroic detectors increase the mapping speed per focal plane area and provide greater discrimination of polarized galactic foregrounds with no increase…
We present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge-sensors…
The Rayleigh limit has so far applied to all microscopy techniques that rely on linear optical interaction and detection in the far field. Here we demonstrate that detecting the light emitted by an object in higher-order transverse…
To further reduce the lattice thermal conductivity of thermoelectric materials, the technique of embedding nano-inclusions into bulk matrix materials, in addition to point defect scattering via alloying, was widely applied. Differential…
A new method for measuring \ngr cross sections aiming at enhanced signal-to-background ratio is presented. This new approach is based on the combination of the pulse-height weighting technique with a total energy detection system that…
This paper describes the advantages and challenges of applying microelectromechanical accelerometer systems (MEMS accelerometers) in order to attain precise, accurate and stateless positioning of telescope mounts. This provides a completely…
The sensitivity of a low-noise superconducting transition edge sensor (TES) is determined by the thermal conductance of the support structure that connects the active elements of the device to the heat bath. Low-noise devices require…