Related papers: Test Beam Study of SiPM-on-Tile Configurations
In this work, we present a novel compact particle identification (PID) detector concept based on Silicon Photomultipliers (SiPMs) optimized to perform combined Ring-Imaging Cherenkov (RICH) and Time-of-Flight (TOF) measurements using a…
We present a generic framework for the simulation of Silicon Photomultipliers (SiPMs) which enables detailed modelling of the SiPM response using basic SiPM parameters and geometry as an input. Depending on the specified SiPM properties…
The Analogue Hadron Calorimeter (AHCAL) developed by the CALICE collaboration is a scalable engineering prototype for a Linear Collider detector. It is a sampling calorimeter of steel absorber plates and plastic scintillator tiles read out…
In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active…
Based on test-beam measurements, we study the response of a liquid-scintillator detector equipped with wavelength-shifting optical modules, that are proposed e.g. for the IceCube experiment and the SHiP experiment, and adiabatic light…
The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate…
Silicon photomultipliers (SiPMs) have become the baseline choice for cameras of the small-sized telescopes (SSTs) of the Cherenkov Telescope Array (CTA). On the other hand, SiPMs are relatively new to the field and covering large surfaces…
In this paper we report on the characterization of SiPM tiles developed for the R & D on the DUNE Photon Detection System. The tiles were produced by Fondazione Bruno Kessler (FBK) employing NUV-HD-SF SiPMs. Special emphasis is given on…
The baseline technology for the Surrounding Background Tagger of the recently approved SHiP experiment relies on liquid scintillator composed of linear alkylbenzene and 2,5-diphenyloxazole as active detector material. The primary…
Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. We report the angular dependence of the specular reflectance in a vacuum of…
Scintillating fibre detectors combine sub-mm resolution particle tracking, precise measurements of the particle stopping power and sub-ns time resolution. Typically, fibres are read out with silicon photomultipliers (SiPM). Hence, if fibres…
Accurate Time-of-Flight (TOF) measurement with sub-100 picosecond resolution is a critical requirement for particle identification in future high-energy physics experiments, such as the Belle II $K_{L}$ and Muon (KLM) detector upgrade.…
The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect…
A prototype plastic scintillating fibre based beam profile monitor was tested at the Heidelberg Ion Therapy Centre / \textit{Heidelberg Ionenstrahl Therapiezentrum} (HIT) in 2016 to determine its beam property reconstruction performance and…
The proton light yield of organic scintillators has been measured extensively in recent years using fast waveform digitizers and large discrepancies exist in the values reported by different authors. In this letter, we address principles of…
Bioluminescence detection requires single-photon sensitivity, extremely low detection limits and wide dynamic range. Such performances were traditionally assured by photomultiplier-tubes based systems. However, development of novel…
The main effect of radiation damage in a Silicon-Photolumtiplier (SiPM) is a dramatic increase in the dark current. The power dissipated, if not properly cooled, heats the SiPM, whose performance parameters depend on temperature. Heating…
Photomultiplier tube (PMT) and Silicon Photo Multiplier (SiPM) are often used for detecting small number of photons or very weak radiations. A light guide usually connects these photodetectors to the test space. In this article, we…
The results obtained in laboratory tests, using scintillator bars read by silicon photomultipliers are reported. The present approach is the first step for designing a precision tracking system to be placed inside a free magnetized volume…
Plastic scintillation detectors represent an efficient, cost-effective, customizable solution for assessment of gamma radiation fields in the context of nuclear security, environmental radiation survey, radiological and nuclear incidents…