English
Related papers

Related papers: Single pixel performance of a 32$\times$32 Ti/Au T…

200 papers

Large format arrays of transition edge sensor (TES) are crucial for the next generation of X-ray space observatories. Such arrays are required to achieve an energy resolution of $\mathrm{\Delta}E<$3 eV full-width-half-maximum (FWHM) in the…

Instrumentation and Methods for Astrophysics · Physics 2021-02-22 E. Taralli , M. D'Andrea , L. Gottardi , K. Nagayoshi , M. Ridder , S. Visser , M. de Wit , D. Vaccaro , H. Akamatsu , K. Ravensberg , R. Hoogeveen , M. Bruijn , J. R. Gao

We are developing the frequency domain multiplexing (FDM) read-out of transition-edge sensor (TES) microcalorimeters for the X-ray Integral Field Unit (X-IFU) instrument on board of the future European X-Ray observatory Athena. The X-IFU…

We are developing X-ray microcalorimeters as a backup option for the baseline detectors in the X-IFU instrument on board the ATHENA space mission led by ESA and to be launched in the early 2030s.5$\times$5 mixed arrays with TiAu…

Instrumentation and Detectors · Physics 2021-02-19 E. Taralli , L. Gottardi , K. Nagayoshi , M. Ridder , S. Visser , P. Khosropanah , H. Akamatsu , J. van der Kuur , M. Bruijn , J. R. Gao

Uniform large transition-edge sensor (TES) arrays are fundamental for the next generation of X-ray space observatories. These arrays are required to achieve an energy resolution $\Delta E$ < 3 eV full-width-half-maximum (FWHM) in the soft…

Instrumentation and Methods for Astrophysics · Physics 2021-02-19 E. Taralli , M. D'Andrea , L. Gottardi , K. Nagayoshi , M. L. Ridder , M. de Wit , D. Vaccaro , H. Akamatsu , M. P. Bruijn , J. R. Gao

We are developing Frequency Domain Multiplexing (FDM) for the read-out of TES imaging microcalorimeter arrays for future X-ray missions like IXO. In the FDMconfiguration the TES is AC voltage biased at a well defined frequencies (between…

We demonstrate a 16-pixel array of radio-frequency superconducting nanowire single-photon detectors with an integrated and scalable frequency-division multiplexing architecture, reducing the required bias and readout lines to a single…

Instrumentation and Detectors · Physics 2017-08-02 Steffen Doerner , Artem Kuzmin , Stefan Wuensch , Ilya Charaev , Florian Boes , Thomas Zwick , Michael Siegel

Frequency domain multiplexing (FDM) is the baseline readout system for the X-ray Integral Field Unit (X-IFU) on board the Athena mission. Under the FDM scheme, TESs are coupled to a passive LC filter and biased with alternating current (AC…

We report our most recent progress and demonstration of a frequency domain multiplexing (FDM) readout technology for transition-edge sensor (TES) arrays, both of which we have been developing, in the framework of the X-IFU instrument on…

Transition-edge sensors (TESs) are used as very sensitive thermometers in microcalorimeters aimed at detection of different wavelengths. In particular, for soft X-ray astrophysics, science goals require very high resolution…

Instrumentation and Detectors · Physics 2021-02-19 E. Taralli , C. Pobes , P. Khosropanah , L. Fabrega , A. Camon , L. Gottardi , K. Nagayoshi , M. Ridder , M. Bruijn , J. R. Gao

The next generation of Far-infrared and X-ray space observatories will require detector arrays with thousands of transition edge sensor (TES) pixel. It is extremely important to have a tool that is able to characterize all the pixels and…

Instrumentation and Detectors · Physics 2021-02-19 E. Taralli , P. Khosropanah , L. Gottardi , K. Nagayoshi , M. L. Ridder , M. P. Bruijn , J. R. Gao

At SRON we have been developing X-ray TES micro-calorimeters as backup technology for the X-ray Integral Field Unit (X-IFU) of the Athena mission, demonstrating excellent resolving powers both under DC and AC bias. We also developed a…

Instrumentation and Methods for Astrophysics · Physics 2025-06-04 D. Vaccaro , H. Akamatsu , L. Gottardi , M. de Wit , M. P. Bruijn , J. van der Kuur , K. Nagayoshi , E. Taralli , K. Ravensberg , J. R. Gao , J. W. A. den Herder

We report on the development and demonstration of a MHz frequency domain multiplexing (FDM) technology to read out arrays of cryogenic transition edge sensor (TES) X-ray microcalorimeters. In our FDM scheme, TESs are AC-biased at different…

Within the ATTRACT FASTPIX project, a monolithic pixel sensor demonstrator chip has been developed in a modified 180 nm CMOS imaging process technology, targeting sub-nanosecond timing precision for single ionising particles. It features a…

At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in an AC bias configuration. For x-ray photons at 6 keV the pixel shows an x-ray energy resolution $dE_{FWHM} =…

We present two implementations of photon counting time-multiplexing detectors for near-infrared wavelengths, based on Peltier cooled InGaAs/InP avalanche photo diodes (APDs). A first implementation is motivated by practical considerations…

Quantum Physics · Physics 2015-05-19 Patrick Eraerds , Jun Zhang , Enrico Pomarico , Bruno Sanguinetti , Rob Thew , Hugo Zbinden

The calibration process for the hybrid array pixel detector designed for High Energy Photon Source in China, we called HEPS-BPIX, is presented in this paper. Based on the threshold scanning, the relationship between energy and threshold is…

Instrumentation and Detectors · Physics 2021-09-01 Ye Ding , Zhenjie Li , Wei Wei , Jie Zhang , Hangxu Li , Yan Zhang , Xiaolu Ji , Peng Liu , Yuanbai Chen , Kejun Zhu

A 1M- and a 4M-pixel monolithic CMOS active pixel sensor with 9.5x9.5 micron^2 pixels have been developed for direct imaging in transmission electron microscopy as part of the TEAM project. We present the design and a full characterisation…

The concept of the radio-frequency superconducting nanowire single-photon detector (RF-SNSPD) allows frequency-division multiplexing (FDM) of the bias and readout lines of several SNSPDs. Using this method, a multi-pixel array can be…

Instrumentation and Detectors · Physics 2020-04-22 Steffen Doerner , Artem Kuzmin , Stefan Wuensch , Ilya Charaev , Michael Siegel

The performance of scintillating fibre detectors was studied with electrons at the spectrometer facility of the Mainz microtron MAMI, as well as in a C-12 beam of 2 AGeV energy and in a beam of different particle species at GSI. Multi-anode…

The Transition-Edge Sensor (TES) is an extremely sensitive device which is used to measure the energy of individual X-ray photons. For astronomical spectrometry applications, SRON develops a Frequency Domain Multiplexing (FDM) read-out…

‹ Prev 1 2 3 10 Next ›