English
Related papers

Related papers: High contrast Ultrafast 3D Ultrasound Imaging usin…

200 papers

The row-column addressed array is an emerging probe for ultrafast 3-D ultrasound imaging. It achieves this with far fewer independent electronic channels and a wider field of view than traditional 2-D matrix arrays, of the same channel…

Row column addressed (RCA) transducers present a promising solution for ultrafast volumetric imaging with a reduced channel count and a large field of view. However, RCA-based 3D imaging is fundamentally limited by severe sidelobe artifacts…

Medical Physics · Physics 2026-04-27 Qiandong Sun , Rui He , Shilin Hou , Jiyan Dai , Kailiang Xu

Row-Column Arrays (RCAs) offer an attractive alternative to fully wired 2D-arrays for 3D-ultrasound, due to their greatly simplified wiring. However, conventional RCAs face challenges related to their long elements. These include an…

Image and Video Processing · Electrical Eng. & Systems 2025-06-13 Randy Palamar , Mohammad Rahim Sobhani , Darren Dahunsi , Negar Majidi , Afshin Kashani Ilkhechi , Joy Wang , Jeremy Brown , Roger Zemp

Beamforming in ultrasound imaging has significant impact on the quality of the final image, controlling its resolution and contrast. Despite its low spatial resolution and contrast, delay-and-sum is still extensively used nowadays in…

Computer Vision and Pattern Recognition · Computer Science 2016-05-20 Teodora Szasz , Adrian Basarab , Denis Kouamé

Real-time three dimensional (3D) ultrasound provides complete visualization of inner body organs and blood vasculature, which is crucial for diagnosis and treatment of diverse diseases. However, 3D systems require massive hardware due to…

Signal Processing · Electrical Eng. & Systems 2020-04-24 Regev Cohen , Nitai Fingerhut , Francois Varray , Herve Liebgott , Yonina C. Eldar

Super-resolution ultrasound imaging has been so far achieved in 3-D by mechanically scanning a volume with a linear probe, by co-aligning multiple linear probes, by using multiplexed 3-D clinical ultrasound systems, or by using 3-D…

High frame rate 3-D ultrasound imaging technology combined with super-resolution processing method can visualize 3-D microvascular structures by overcoming the diffraction limited resolution in every spatial direction. However, 3-D…

Three-dimensional ultrasound enables real-time volumetric visualization of anatomical structures. Unlike traditional 2D ultrasound, 3D imaging reduces reliance on precise probe orientation, potentially making ultrasound more accessible to…

Image and Video Processing · Electrical Eng. & Systems 2026-05-05 Tristan S. W. Stevens , Oisín Nolan , Oudom Somphone , Jean-Luc Robert , Ruud J. G. van Sloun

The standard technique used by commercial medical ultrasound systems to form B-mode images is delay and sum (DAS) beamforming. However, DAS often results in limited image resolution and contrast, which are governed by the center frequency…

Information Theory · Computer Science 2018-08-06 Regev Cohen , Yonina C. Eldar

The possibility to obtain a three-dimensional representation of a single object with sub-$\mu$m resolution is crucial in many fields, from material science to clinical diagnostics. This is typically achieved through tomography, which…

We propose a novel solution for volumetric ultrasound imaging using single-side access 3-D synthetic-aperture scanning of a clinical linear array. This solution is based on an advanced scanning geometry and a software-based ultrasound…

Medical Physics · Physics 2021-01-27 Théotim Lucas , Isabelle Quidu , S. Lori Bridal , Jerome Gateau

One of the key steps in ultrasound image formation is digital beamforming of signals sampled by several transducer elements placed upon an array. High-resolution digital beamforming introduces the demand for sampling rates significantly…

Information Theory · Computer Science 2015-08-21 Amir Burshtein , Michael Birk , Tanya Chernyakova , Alon Eilam , Arcady Kempinskiand , Yonina C. Eldar

Linear-array based photoacoustic images are reconstructed using the conventional delay-and-sum (DAS) beamforming method. Although the DAS beamformer is well suited for PA image formation, reconstructed images are often afflicted by noises,…

Medical Physics · Physics 2022-10-05 Sufayan Mulani , Souradip Paul , Mayanglambam Suheshkumar Singh

In-air acoustic imaging systems demand beamforming techniques that offer a high dynamic range and spatial resolution while also remaining robust. Conventional Delay-and-Sum (DAS) beamforming fails to meet these quality demands due to high…

Signal Processing · Electrical Eng. & Systems 2026-01-28 Wouter Jansen , Walter Daems , Jan Steckel

Among various choices of 2-D ultrasound transducer arrays, the row-column-addressed (RCA) 2-D array has shown its promise for 3-D imaging. However, RCA suffers from notable edge effects and thus receives ghost echoes, which result in ghost…

Signal Processing · Electrical Eng. & Systems 2023-08-29 Chung-Shiang Mei , Meng-Lin Li

Coherent multi-transducer ultrasound (CoMTUS) creates an extended effective aperture through the coherent combination of multiple arrays, which results in images with enhanced resolution, extended field-of-view, and higher sensitivity. The…

Three-dimensional (3D) ultrasound promises various medical applications for abdominal, obstetrics, and breast imaging. However, ultrasound matrix arrays have extremely high element counts limiting their field of view (FOV). Current reduced…

Signal Processing · Electrical Eng. & Systems 2026-04-17 Mick Gardner , Michael L. Oelze

Ocean exploration using acoustical 3D imaging is gaining popularity as it provides information about the 3D geometry of the targets even under mild turbid conditions. A major challenge in underwater 3D imaging is the high cost of the planar…

Signal Processing · Electrical Eng. & Systems 2024-11-15 Mimisha M Menakath , Mahesh Raveendranatha Panicker , Hareesh G

In Ultrasound (US) imaging, Delay and Sum (DAS) is the most common beamformer, but it leads to low quality images. Delay Multiply and Sum (DMAS) was introduced to address this problem. However, the reconstructed images using DMAS still…

Signal Processing · Electrical Eng. & Systems 2018-01-19 Moein Mozaffarzadeh , Masume Sadeghi , Ali Mahloojifar , Mahdi Orooji

In portable, three dimensional, and ultra-fast ultrasound imaging systems, there is an increasing demand for the reconstruction of high quality images from a limited number of radio-frequency (RF) measurements due to receiver (Rx) or…

Computer Vision and Pattern Recognition · Computer Science 2018-08-08 Yeo Hun Yoon , Shujaat Khan , Jaeyoung Huh , Jong Chul Ye