English
Related papers

Related papers: Optical Calibration System for the LUX-ZEPLIN (LZ)…

200 papers

We present the results of a direct detection search for mirror dark matter interactions, using data collected from the Large Underground Xenon experiment during 2013, with an exposure of 95 live-days $\times$ 118 kg. Here, the calculations…

This master thesis presents a new type of Positron Emission TOF Apparatus using Liquid xenOn (PETALO). The detector is based in the Liquid Xenon Scintillating Cell (LXSC). The cell is a box filled with liquid xenon (LXe) whose transverse…

Medical Physics · Physics 2016-06-01 J. M. Benlloch-Rodriguez

Dark matter detectors that utilize liquid xenon have now achieved tonne-scale targets, giving them sensitivity to all flavours of supernova neutrinos via coherent elastic neutrino-nucleus scattering. Considering for the first time a…

High Energy Astrophysical Phenomena · Physics 2016-12-21 Rafael F. Lang , Christopher McCabe , Shayne Reichard , Marco Selvi , Irene Tamborra

We report here on the results from the Weakly Interacting Massive Particle (WIMP) search with the LUX dark matter experiment. LUX, a two-phase xenon time projection chamber (TPC) with 250 kg of active mass, has been operated from 2012 until…

High Energy Physics - Experiment · Physics 2017-10-11 Cláudio Frederico Pascoal da Silva

We show that dark matter with a per-nucleon scattering cross section $\gtrsim 10^{-28}~{\rm cm^2}$ could be discovered by liquid scintillator neutrino detectors like BOREXINO, SNO+, and JUNO. Due to the large dark matter fluxes admitted,…

High Energy Physics - Phenomenology · Physics 2019-04-24 Joseph Bramante , Benjamin Broerman , Jason Kumar , Rafael F. Lang , Maxim Pospelov , Nirmal Raj

The PandaX-xT is a next-generation experiment with broad scientific goals, including the search for dark matter, Neutrinoless Double Beta Decay, and astrophysical neutrinos, using a dual-phase time projection chamber with about 43 tons of…

Instrumentation and Detectors · Physics 2026-04-09 Xu Wang , Li Zhao , Xiang Xiao , Xiangyi Cui , Shuaijie Li , Jianglai Liu

The use of low-temperature detectors, such as cryogenic calorimeters, has pioneered the recent advancements in low-energy rare event searches. These detectors provide a low-noise environment essential for the direct detection of dark matter…

Instrumentation and Detectors · Physics 2026-02-25 Giorgio Del Castello

A LED-based fiber calibration system for the ProtoDUNE-Dual Phase (DP) photon detection system (PDS) has been designed and validated. ProtoDUNE-DP is a 6x6x6 m3 liquid argon time-projection-chamber currently being installed at the Neutrino…

The LZ dark matter detector, like many other rare-event searches, will suffer from backgrounds due to the radioactive decay of radon daughters. In order to achieve its science goals, the concentration of radon within the xenon should not…

Instrumentation and Detectors · Physics 2018-01-17 E. H. Miller , J. Busenitz , T. K. Edberg , C. Ghag , C. Hall , R. Leonard , K. Lesko , X. Liu , Yue Meng , A. Piepke , R. W. Schnee

Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $\gamma$ interactions from…

The nuGeN experiment searches for coherent elastic neutrino-nucleus scattering (CEvNS) at the Kalinin Nuclear Power Plant. A 1.41-kg high-purity low-threshold germanium detector surrounded by active and passive shielding is deployed at the…

This note presents revised detector parameters applicable to data from the First Science Run of the ZEPLIN-III dark matter experiment; these datasets were acquired in 2008 and reanalised in 2011. This run demonstrated electron recoil…

Instrumentation and Detectors · Physics 2020-07-06 Henrique Araújo

DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles (WIMPs). It utilizes a liquid argon time projection chamber (LAr TPC) for the inner main detector. The TPC is surrounded by a liquid…

Instrumentation and Detectors · Physics 2017-02-06 P. Agnes , L. Agostino , I. F. M. Albuquerque , T. Alexander , A. K. Alton , K. Arisaka , H. O. Back , B. Baldin , K. Biery , G. Bonfini , M. Bossa , B. Bottino , A. Brigatti , J. Brodsky , F. Budano , S. Bussino , M. Cadeddu , M. Cadoni , F. Calaprice , N. Canci , A. Candela , H. Cao , M. Cariello , M. Carlini , S. Catalanotti , P. Cavalcante , A. Chepurnov , A. G. Cocco , G. Covone , L. Crippa , D. D'Angelo , M. D'Incecco , S. Davini , S. De Cecco , M. De Deo , M. De Vincenzi , A. Derbin , A. Devoto , F. Di Eusanio , G. Di Pietro , E. Edkins , A. Empl , A. Fan , G. Fiorillo , K. Fomenko , G. Foster , D. Franco , F. Gabriele , C. Galbiati , C. Giganti , A. M. Goretti , F. Granato , L. Grandi , M. Gromov , M. Guan , Y. Guardincerri , B. R. Hackett , K. R. Herner , E. V. Hungerford , Aldo Ianni , Andrea Ianni , I. James , C. Jollet , K. Keeter , C. L. Kendziora , V. Kobychev , G. Koh , D. Korablev , G. Korga , A. Kubankin , X. Li , M. Lissia , P. Lombardi , S. Luitz , Y. Ma , I. N. Machulin , A. Mandarano , S. M. Mari , J. Maricic , L. Marini , C. J. Martoff , A. Meregaglia , P. D. Meyers , T. Miletic , R. Milincic , D. Montanari , A. Monte , M. Montuschi , M. E. Monzani , P. Mosteiro , B. J. Mount , V. N. Muratova , P. Musico , J. Napolitano , A. Nelson , S. Odrowski , M. Orsini , F. Ortica , L. Pagani , M. Pallavicini , E. Pantic , S. Parmeggiano , K. Pelczar , N. Pelliccia , A. Pocar , S. Pordes , D. A. Pugachev , H. Qian , K. Randle , G. Ranucci , A. Razeto , B. Reinhold , A. L. Renshaw , Q. Riffard , A. Romani , B. Rossi , N. Rossi , S. D. Rountree , D. Sablone , P. Saggese , R. Saldanha , W. Sands , S. Sangiorgio , C. Savarese , E. Segreto , D. A. Semenov , E. Shields , P. N. Singh , M. D. Skorokhvatov , O. Smirnov , A. Sotnikov , C. Stanford , Y. Suvorov , R. Tartaglia , J. Tatarowicz , G. Testera , A. Tonazzo , P. Trinchese , E. V. Unzhakov , A. Vishneva , R. B. Vogelaar , M. Wada , S. Walker , H. Wang , Y. Wang , A. W. Watson , S. Westerdale , J. Wilhelmi , M. M. Wojcik , X. Xiang , J. Xu , C. Yang , J. Yoo , S. Zavatarelli , A. Zec , W. Zhong , C. Zhu , G. Zuzel

Sterile neutrinos are a minimal extension of the Standard Model of Particle Physics. If their mass is in the kilo-electron-volt regime, they are viable dark matter candidates. One way to search for sterile neutrinos in a laboratory-based…

PandaX-4T, the new generation of the PandaX detector, is a xenon dual-phase detector with about six tons of liquid xenon as target for dark matter search. A cryogenics and xenon handling system is designed to liquify and purify this large…

Instrumentation and Detectors · Physics 2021-08-11 Li Zhao , Xiangyi Cui , Wenbo Ma , Yingjie Fan , Karl Giboni , Tao Zhang , Jianglai Liu , Xiangdong Ji

Precise temperature monitoring -- to the level of a few milli-Kelvin -- is essential for the operation of large-scale cryostats requiring a recirculation system. In particular, the performance of Liquid Argon Time Projection Chambers --…

Instrumentation and Detectors · Physics 2025-06-09 Maria Antonova , Jordi Capó , Anselmo Cervera , Pablo Fernández , Miguel Á. García-Peris , Xavier Pons

Future experiments dedicated to the detection of Coherent Elastic Neutrino-Nucleus Scattering may be powerful tools in probing light new physics. In this paper we study the sensitivity on light $Z'$ mediators of two proposed experiments: a…

High Energy Physics - Phenomenology · Physics 2022-06-24 Enrico Bertuzzo , Giovanni Grilli di Cortona , Lucas Magno D. Ramos

We present a concept of a one ton two-phase liquid Xenon detector based on the concept of the ZEPLIN II detector currently under construction by a UCLA/Torino/UKDM team. The ZEPLIN II detector may be installed in the Boulby laboratory early…

Astrophysics · Physics 2007-05-23 David B. Cline , Hanguo Wang , Y. Seo

In the case of underground experiments for neutrino physics or rare event searches, the background caused by cosmic muons contributes significantly and therefore must be identified and rejected. We proposed and optimized a new detector…

Instrumentation and Detectors · Physics 2017-04-05 Y. P. Zhang , J. L. Xu , H. Q. Lu , P. Zhang , C. C. Zhang , C. G. Yang