English
Related papers

Related papers: Improvements on INRIM Coaxial Microcalorimeter and…

200 papers

Thermoelectric power sensors used as power transfer standards are promising devices for further enhancements of the microcalorimetric technique in the high frequency field. A coaxial microcalorimeter has been studied, based on…

Instrumentation and Detectors · Physics 2021-03-09 L. Brunetti , L. Oberto , M. Sellone , E. Vremera

The high frequency primary power standard is univocally realized by means of a coaxial microcalorimeter, at least up to 40 GHz. The coaxial microcalorimeter is a broadband measurement system adjusted for effec-tive efficiency measurement of…

Instrumentation and Detectors · Physics 2021-03-09 Luciano Brunetti , Luca Oberto , Marco Sellone

Primary power standards in the microwave domain are realized using a calorimetric technique, usually identified with the used measurement system, i.e., the microcalorimeter. It is adjusted for measurement of power ratios with a relative…

Instrumentation and Detectors · Physics 2021-03-09 L. Brunetti , L. Oberto

Thermoelectric power sensors can now be used as transfer standards, instead of bolometers, in the microcalorimeter technique. This alternative has the technical advantages to be less sensitive to absolute temperature and not downward…

Instrumentation and Detectors · Physics 2021-03-09 L. Brunetti , L. Oberto , E. Vremera

In the paper, a comparison is described of the microwave power standard based on thermoelectric sensors against an analogous standard based on bolometric sensors. Measurements have been carried out with the classical twin-type…

Instrumentation and Detectors · Physics 2021-02-24 Luciano Brunetti , Luca Oberto , Marco Sellone , Emil Vremera

The paper describes the realization process of the high frequency power standard based on a twin broadband microcalorimeter designed for effective efficiency measurement of coaxial power sensors with indirect heating thermocouples. The…

Instrumentation and Detectors · Physics 2021-03-09 Emil Vremera , Luciano Brunetti , Luca Oberto , Marco Sellone

Microcalorimeters are used by National Metrology Institutes (NMI) for the realization of the Radiofrequency and Microwaves (RF&MW) primary power standard. Since they are not available on the market, NMIs have to design their own systems. It…

Instrumentation and Detectors · Physics 2021-07-02 Luca Oberto

The standard non-equilibrium theory of noise in ideal bolometers and microcalorimeters fails to predict the performance of real devices due to additional effects that become important at low temperature. In this paper we extend the theory…

Astrophysics · Physics 2009-11-07 M. Galeazzi , D. McCammon

Thermoelectric power sensors are widely used in commercial power meters at RF and microwaves, due to their superior robustness, stability, and accuracy if compared with other types of power sensors. Furthermore, their electrical…

Instrumentation and Detectors · Physics 2021-02-12 Luca Oberto , Luciano Brunetti

The nonlinear energy response of cryogenic microcalorimeters is usually corrected through an empirical calibration. X-ray or gamma-ray emission lines of known shape and energy anchor a smooth function that generalizes the calibration data…

Instrumentation and Detectors · Physics 2022-08-23 J. W. Fowler , B. K. Alpert , G. C. O'Neil , D. S. Swetz , J. N. Ullom

Broadband seismometers are widely used in global observation networks deployed for geophysics research. Recently, the calibration of their sensitivity has become an important factor for ensuring observation accuracy. One of the limiting…

Geophysics · Physics 2026-03-03 Tomofumi Shimoda , Wataru Kokuyama , Hideaki Nozato

In this paper, the calorimetric power measurement method for electron cyclotron resonance heating system on EAST are presented. This method requires measurement of the water flow through the cooling circuits and the input and output water…

Plasma Physics · Physics 2017-08-22 Weiye Xu , Handong Xu , Fukun Liu , Jian Wang , Xiaojie Wang , Yongzhong Hou

With the successful construction and operation of a highly granular hadron calorimeter system, featuring approx. 22000 individually read out SiPM-on-tile channels, the CALICE collaboration has set the next milestone in proving the…

Instrumentation and Detectors · Physics 2022-11-09 Daniel Heuchel

Near-equilibrium thermal detectors operate as classical calorimeters, with energy deposition and internal equilibration times short compared to the thermal time constant of the device. Advances in fabrication techniques, cryogenics, and…

Instrumentation and Detectors · Physics 2015-06-26 Dan McCammon

This paper describes the experience with the calibration, reconstruction and evaluation of the timing capabilities of the CMS HGCAL prototype in the beam tests in 2018. The calibration procedure includes multiple steps and corrections…

Instrumentation and Detectors · Physics 2024-04-15 CMS HGCAL collaboration

We demonstrate a microfabricated optomechanical accelerometer that is capable of percent-level accuracy without external calibration. To achieve this capability, we use a mechanical model of the device behavior that can be characterized by…

Instrumentation and Detectors · Physics 2022-05-25 Benjamin J. Reschovsky , David A. Long , Feng Zhou , Yiliang Bao , Richard A. Allen , Thomas W. LeBrun , Jason J. Gorman

We present a novel internal calibration framework for Millimeter- Wave (mmWave) Frequency-Modulated Continuous-Wave (FMCW) radars to ensure robust performance under internal temperature variations, tailored for deployment in dense wireless…

Signal Processing · Electrical Eng. & Systems 2025-11-06 Dariush Salami , Nima Bahmani , Hüseyin Yiğitler , Stephan Sigg

Empirical estimates of the band power covariance matrix are commonly used in cosmic microwave background (CMB) power spectrum analyses. While this approach easily captures correlations in the data, noise in the resulting covariance estimate…

Cosmology and Nongalactic Astrophysics · Physics 2022-03-14 L. Balkenhol , C. L. Reichardt

Optical frequency stabilization is a critical component for precision scientific systems including quantum sensing, precision metrology, and atomic timekeeping. Ultra-high quality factor photonic integrated optical resonators are a prime…

This is the report on new development of an automated precision load-based measurement setup for thermoelectric power of different types of samples in the temperature range 5 - 330 K. The problems in the old spring-based setup have been…

Applied Physics · Physics 2019-03-12 Tarachand , Monika Saxena , Bodhoday Mukherjee , Gunadhor S. Okram
‹ Prev 1 2 3 10 Next ›