English
Related papers

Related papers: Electroluminescence yield in pure krypton

200 papers

Detectors with an electroluminesence readout show an excellence performance in respect of energy resolution making them interesting for various applications as X-ray detection, double beta and dark matter experiments, Compton and gamma…

Instrumentation and Detectors · Physics 2015-03-18 T. Lux , O. Ballester , J. Illa , G. Jover , C. Martin , J. Rico , F. Sanchez

The possibility of efficient collection and detection of vacuum ultraviolet light as emitted by argon, krypton, and xenon gas is studied. Absolute quantum efficiencies of large area avalanche photodiodes (LAAPDs) are derived at these…

Instrumentation and Detectors · Physics 2016-11-15 R. Chandrasekharan , A. Knecht , M. Messina , C. Regenfus , A. Rubbia

We have combined ab initio quantum chemistry calculations with a rate-equation formalism to analyze electroluminescence spectra in single-molecule junctions, measured recently by several groups in Scanning Tunneling Microscope setups. In…

Mesoscale and Nanoscale Physics · Physics 2010-05-20 Johannes S. Seldenthuis , Herre S. J. van der Zant , Mark A. Ratner , Joseph M. Thijssen

Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $\gamma$ interactions from…

Photoelectron yields of extruded scintillation counters with titanium dioxide coating and embedded wavelength shifting fibers read out by silicon photomultipliers have been measured at the Fermilab Test Beam Facility using 120\,GeV protons.…

Large Area Avalanche Photodiodes (LAAPDs) were used for a series of systematic measurements of the scintillation light in Ar, Kr, and Xe gas. Absolute quantum efficiencies are derived. Values for Xe and Kr are consistent with those given by…

Instrumentation and Detectors · Physics 2009-11-10 R. Chandrasekharan , M. Messina , A. Rubbia

The performance of a silicon photomultiplier has been assessed at low temperature in order to evaluate its suitability as a scintillation readout device in liquid argon particle physics detectors. The gain, measured as 2.1E6 for a constant…

Instrumentation and Detectors · Physics 2011-06-09 P. K. Lightfoot , G. J. Barker , K. Mavrokoridis , Y. A. Ramachers , N. J. C. Spooner

A novel concept of optical signal recording in two-phase avalanche detectors, with Geiger-mode Avalanche Photodiodes (G-APD) is described. Avalanche-scintillation photons were measured in a thick Gas Electron Multiplier (THGEM) in view of…

Instrumentation and Detectors · Physics 2011-04-07 A. Bondar , A. Buzulutskov , A. Grebenuk , A. Sokolov , D. Akimov , I. Alexandrov , A. Breskin

We present a gated silicon single photon detector based on a commercially available avalanche photodiode. Our detector achieves a photon detection efficiency of 45\pm5% at 808 nm with 2x 10^-6 dark count per ns at -30V of excess bias and…

Instrumentation and Detectors · Physics 2015-06-11 T. Lunghi , E. Pomarico , C. Barreiro , D. Stucki , B. Sanguinetti , H. Zbinden

Radiation-induced proportional-electroluminescence UV signals, emitted from the holes of a Thick Gas Electron Multiplier (THGEM) electrode immersed in liquid xenon, were recorded with a PMT for the first time. Significant photon yields were…

Instrumentation and Detectors · Physics 2015-06-17 L. Arazi , A. E. C. Coimbra , R. Itay , H. Landsman , L. Levinson , M. L. Rappaport , D. Vartsky , A. Breskin

We report the first measurements of the absolute ionization yield of nuclear recoils in liquid xenon, as a function of energy and electric-field. Independent experiments were carried out with two dual-phase time projection chamber…

The quantum yield of synthetic eumelanin is known to be extremely low and it has recently been reported to be dependent on excitation wavelength. In this paper, we present quantum yield as a function of excitation wavelength between 250 and…

Chemical Physics · Physics 2009-11-11 Stephen Nighswander-Rempel , Jennifer Riesz , Joel Gilmore , Paul Meredith

The air-fluorescence yield is a key parameter for determining the energy scale of ultra-high-energy cosmic rays detected by fluorescence telescopes. A compilation of the available measurements of the absolute air-fluorescence yield…

Instrumentation and Methods for Astrophysics · Physics 2011-03-11 J. Rosado , F. Blanco , F. Arqueros

Liquid nitrogen is commonly used in cryogenic applications and is a promising medium for the direct immersion cooling of sensors used for nuclear and particle physics experiments. The scintillation properties of gaseous nitrogen are…

Instrumentation and Detectors · Physics 2025-10-28 L. Pagani , R. Saldanha , B. M. Loer , G. S. Ortega , R. A. Bunker , B. T. Foust

The main purpose of this work is to provide reference data on X-ray ionization yields and energy spectra in liquid Ar to the studies in the field of Cryogenic Avalanche Detectors (CRADs) for rare-event and other experiments, based on liquid…

Instrumentation and Detectors · Physics 2016-02-19 A. Bondar , A. Buzulutskov , A. Dolgov , L. Shekhtman , A. Sokolov

We have developed a new method to measure krypton traces in xenon at unprecedented low concentrations. This is a mandatory task for many near-future low-background particle physics detectors. Our system separates krypton from xenon using…

Instrumentation and Detectors · Physics 2014-03-28 Sebastian Lindemann , Hardy Simgen

Scintillation at cryogenic temperatures can give rise to detectors with particle discrimination for rare-event searches such as dark matter detection. We present time-resolved scintillation studies of Caesium Iodide (CsI) under excitation…

Instrumentation and Detectors · Physics 2018-06-18 Michael Clark , Patrick Nadeau , Shane Hills , Christophe Dujardin , Philippe Di Stefano

NaI(Tl) crystals are used as particle detectors in a variety of rare-event search experiments because of their superb light-emission quality. The crystal light yield is generally high, above 10 photoelectrons per keV, and its emission…

Instrumentation and Detectors · Physics 2020-08-13 J. J. Choi , B. J. Park , C. Ha , K. W. Kim , S. K. Kim , Y. D. Kim , Y. J. Ko , H. S. Lee , S. H. Lee , S. L. Olsen

We have studied the feasibility of a silicon photomultiplier (SiPM) to detect liquid xenon (LXe) scintillation light. The SiPM was operated inside a small volume of pure LXe, at -95 degree Celsius, irradiated with an internal Am-241 alpha…

Instrumentation and Detectors · Physics 2009-11-11 E. Aprile , P. Cushman , K. Ni , P. Shagin

Detection of low-intensity light relies on the conversion of photons to photoelectrons, which are then multiplied and detected as an electrical signal. To measure the actual intensity of the light, one must know the factor by which the…