English
Related papers

Related papers: Pulse processing in TES detectors: comparison of d…

200 papers

The Transition-Edge Sensor (TES) is an extremely sensitive device which is used to measure the energy of individual X-ray photons. For astronomical spectrometry applications, SRON develops a Frequency Domain Multiplexing (FDM) read-out…

The advent of isolated and intense sub-femtosecond X-ray pulses enables tracking of quantummechanical motion of electrons in molecules and solids. The combination of X-ray spectroscopy and diffraction imaging is a powerful approach to…

The ATHENA X-IFU development program foresees to build and characterize an instrument Demonstration Model (DM), in order to probe the system critical technologies before the mission adoption. In this respect, we are now developing the DM of…

Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now…

The XGIS (X and Gamma Imaging Spectrometer) is one of the three instruments onboard the THESEUS mission (ESA M5, currently in Phase-A). Thanks to its wide field of view and good imaging capabilities, it will efficiently detect and localize…

The so-called "optimal filter" analysis of a microcalorimeter's x-ray pulses is statistically optimal only if all pulses have the same shape, regardless of energy. The shapes of pulses from a nonlinear detector can and do depend on the…

Data Analysis, Statistics and Probability · Physics 2017-02-03 J. W. Fowler , B. K. Alpert , W. B. Doriese , J. Hays-Wehle , Y. -I. Joe , K. M. Morgan , G. C. O'Neil , C. D. Reintsema , D. R. Schmidt , J. N. Ullom , D. S. Swetz

Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20 keV energy range. We are building a TES-based instrument for the…

Instrumentation and Detectors · Physics 2020-08-26 Tejas Guruswamy , Lisa M. Gades , Antonino Miceli , Umeshkumar M. Patel , John T. Weizeorick , Orlando Quaranta

The Wide Field Imager (WFI) is one of the two scientific instruments proposed for the Athena+ X-ray observatory. It will provide imaging in the 0.1-15 keV band over a wide field, simultaneously with spectrally and time-resolved photon…

The depleted p-channel field effect transistor is the chosen sensor type for the Wide Field Imager of the Athena mission. It will be used in two types of cameras. One will enable observations of a field of view of 40' x 40' by using an…

Superconducting transition-edge sensors (TES) are extremely sensitive microcalorimeters used as photon detectors with unparalleled energy resolution. They have found application from measuring astronomical spectra through to determining the…

One of the science goals of the Wide Field Imager (WFI) on ESA's Athena X-ray observatory is to map hot gas structures in the universe, such as clusters and groups of galaxies and the intergalactic medium. These deep observations of faint…

Transition Edge Sensors (TESs) are amongst the most sensitive cryogenic detectors and can be easily optimized for the detection of massive particles or photons ranging from X-rays all the way down to millimetre radiation. Furthermore, TESs…

Instrumentation and Detectors · Physics 2024-11-05 Mario De Lucia , Paolo Dal Bo , Eugenia Di Giorgi , Tommaso Lari , Claudio Puglia , Federico Paolucci

The European XFEL, currently under construction, will produce a coherent X-ray pulse every 222 ns in pulse trains of up to 2700 pulses. In conjunction with the fast 2D area detectors currently under development, it will be possible to…

Instrumentation and Detectors · Physics 2011-11-17 Julian Becker , Christian Gutt , Heinz Graafsma

The European X-ray Free Electron Laser (XFEL.EU) will provide unprecedented peak brilliance and ultra-short and spatially coherent X-ray pulses in an energy range of 0.25 to 25 keV . The pulse timing structure is unique with a burst of 2700…

We present a detailed thermal and electrical model of superconducting transition edge sensors (TESs) connected to quasiparticle (qp) traps, such as the W TESs connected to Al qp traps used for CDMS (Cryogenic Dark Matter Search) Ge and Si…

Instrumentation and Detectors · Physics 2014-06-30 B. Shank , J. J. Yen , B. Cabrera , J. M. Kreikebaum , R. Moffatt , P. Redl , B. A. Young , P. L. Brink , M. Cherry , A. Tomada

Transition edge sensors (TESs) are superconducting energy-resolving microcalorimeters that have demonstrated low background rates as well as quantum efficiencies close to unity for photons at optical and near-infrared wavelengths. This…

Optimal filtering is the crucial technique for the data analysis of transition-edge-sensor (TES) calorimeters to achieve their state-of-the-art energy resolutions. Filtering out the `bad' data from the dataset is important because it…

Instrumentation and Methods for Astrophysics · Physics 2022-04-26 Y. Ichinohe , S. Yamada , R. Hayakawa , S. Okada , T. Hashimoto , H. Tatsuno , H. Suda , T. Okumura

ESA's mission Euclid, while undertaking its final integration stage, is fully qualified. Euclid will perform an extragalactic survey ($0<z<2$) by observing in the visible and near-infrared wavelength range. To detect infrared radiation, it…

Array-based, direct-sampling radio telescopes have computational and communication requirements unsuited to conventional computer and cluster architectures. Synchronization must be strictly maintained across a large number of parallel data…

This project explores the design and development of a transition edge sensor (TES) spectrometer for resonant soft X- ray scattering (RSXS) measurements developed in collaboration between Argonne National Laboratory (ANL) and the National…