Related papers: Analysis Of Radiation Dose Distribution Inhomogeni…
Monte Carlo simulation with PENELOPE (v.~2003) is applied to calculate Leksell Gamma Knife$^{\circledR}$ dose distributions for heterogeneous phantoms. The usual spherical water phantom is modified with a spherical bone shell simulating the…
A simplification of the source channel geometry of the Leksell Gamma Knife$^{\circledR}$, recently proposed by the authors and checked for a single source configuration (Al-Dweri et al 2004), has been used to calculate the dose…
In this paper we investigate, with a detailed Monte-Carlo simulation based on Geant4, the novel approach [Nucl. Instrum. Methods A588 (2008) 457] to 3D imaging with photon scattering. A monochromatic and well collimated gamma beam is used…
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric properties of monoenergetic photon point sources in water. The dose rate in water has been calculated for energies of interest…
Purpose: To develop a Monte Carlo (MC) therapeutic dose calculation toolkit of a recently released ring gantry linac in Geant4 (Version 10.7) for secondary dose validation of radiotherapy plan. Methods: For the Halcyon (Varian Medical…
The percentage depth dose distributions in inhomogeneous phantoms with lung and bone equivalent media are studied. For lung equivalent media a Balsa wood is used, and for a soft bone equivalent media a compound material with epoxy resin,…
Novel radiotherapy techniques like synchrotron X-ray microbeam radiation therapy (MRT), require fast dose distribution predictions that are accurate at the sub-mm level, especially close to tissue/bone/air interfaces. Monte Carlo physics…
Monte Carlo simulations using the code PENELOPE have been performed to test a simplified model of the source channel geometry of the Leksell GammaKnife$^{\circledR}$. The characteristics of the radiation passing through the treatment…
Objective: Research on eye lens dosimetry for radiation workers has increased after the 2012 ICRP118 update on eye lens dose limits. However, corneal dosimetry remains underexplored due to historical focus and measurement challenges. This…
Pencil x-ray beam imaging provides superior spatial resolution than other imaging geometries like sheet beam and cone beam geometries due to the illumination of a line instead of an area or volume. However, the pencil beam geometry suffers…
Purpose: To develop a machine learning-based, 3D dose prediction methodology for Gamma Knife (GK) radiosurgery. The methodology accounts for cases involving targets of any number, size, and shape. Methods: Data from 322 GK treatment plans…
The purpose of our study is to develop a new, 3-dimensional dosimetry system to verify the accuracy of dose deliveries in Leksell Gamma Knife-Perfexion TM (LGKP) (Elekta, Norcross, GA, USA). The instrument consists of a moving head phantom,…
Purpose: Retinoblastoma (RB) is the most common eye tumor in childhood and can be treated external radiotherapy. The purpose of this work is to evaluate the adequacy of Monte Carlo simulations and the accuracy of a commercial treatment…
Purpose: To assess the effects of brain movements induced by heartbeat on dose distributions in synchrotron micro- and mini-beam radiaton therapy and to develop a model to help guide decisions and planning for future clinical trials.…
A proton pencil beam is associated with a surrounding low-dose envelope, originating from nuclear interactions. It is important for treatment planning systems to accurately model this envelope when performing dose calculations for pencil…
Treatment planning system calculations in inhomogeneous regions may present significant inaccuracies due to loss of electronic equilibrium. In this study, three different dose calculation algorithms, pencil beam, collapsed cone, and…
Cone beam CT (CBCT) has been widely used for patient setup in image guided radiation therapy (IGRT). Radiation dose from CBCT scans has become a clinical concern. The purposes of this study are 1) to commission a GPU-based Monte Carlo (MC)…
Accurate proton dose calculation using Monte Carlo (MC) is computationally demanding in workflows like robust optimisation, adaptive replanning, and probabilistic inference, which require repeated evaluations. To address this, we develop a…
A Geant4-based Monte Carlo model for Heavy-Ion Therapy (MCHIT) is used to study radiation fields of H-1, He-4, Li-7 and C-12 beams with similar ranges (~160-180 mm) in water. Microdosimetry spectra are simulated for wall-less and walled…
An intercomparison exercise is described that examines Monte Carlo modelling of anthropomorphic voxel phantoms in an idealized ground-contamination photon exposure scenario. Thirteen participants calculated and submitted organ and effective…