English
Related papers

Related papers: Characterization of VUV4 SiPM for Liquid Argon Det…

200 papers

Particle detectors based on liquid argon (LAr) have recently become recognized as an extremely attractive technology for the direct detection of dark matter as well as the measurement of coherent elastic neutrino-nucleus scattering…

Instrumentation and Detectors · Physics 2020-06-03 Cong Guo , Mengyun Guan , Xilei Sun , Weixing Xiong , Peng Zhang , Changgen yang

Liquid argon is used as a target material in several current and planned experiments related to dark matter direct searching and neutrino detection. SiPM is becoming the standard for scintillator detectors because of its advantages over…

Instrumentation and Detectors · Physics 2023-01-03 L. Wang , Y. Lei , T. A. Wang , C. Guo , K. K. Zhao , X. H. Liang , S. B. Wang , Y. D. Chen

Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is…

Silicon photomultiplier (SiPM), a new type of photosensor, is considered a substitute for traditional photomultiplier tube (PMT) in the next generation of dark matter and neutrino detectors, especially in noble gas detectors like liquid…

Instrumentation and Detectors · Physics 2023-05-31 T. A. Wang , C. Guo , X. H. Liang , L. Wang , M. Y. Guan , C. G. Yang , J. C. Liu , F. Y. Lin

Liquid Argon (LAr) is used as a target material in several current and planned experiments related to dark matter direct searching and neutrino detection. Argon provides excellent Pulse Shape Discrimination (PSD) capability which could…

Instrumentation and Detectors · Physics 2023-09-26 L. Wang , Y. Liu , M. Y. Guan , T. A. Wang , C. Guo , J. C. Liu , C. G. Yang , X. H. Liang , Y. D. Chen

Liquid argon time projection chambers (TPC) are widely used in neutrino oscillation and dark matter experiments. Detection of scintillation light in liquid argon TPC's is challenging because of its short wavelength, in the VUV range, and…

SiPM-based readouts are becoming the standard for light detection in particle detectors given their superior resolution and ease of use with respect to vacuum tube photo-multipliers. However, the contributions of detection noise such as the…

Liquid xenon and liquid argon detectors are leading the direct dark matter search and are expected to be the candidate technology for the forthcoming generation of ultra-sensitive large-mass detectors. At present, the scintillation light…

High Energy Physics - Experiment · Physics 2022-09-20 Alessandro Razeto , Nicola Rossi

ArDM is a new-generation WIMP detector which will measure simultaneously light and charge from scintillation and ionization of liquid argon. Our goal is to construct, characterize and operate a 1 ton liquid argon underground detector. The…

Instrumentation and Detectors · Physics 2015-05-13 Vittorio Boccone

We investigate novel strategies to extend the sensitivity of dark matter direct detection experiments to energy deposits well below the thresholds of conventional detectors. In liquid-argon time-projection chambers equipped with silicon…

Instrumentation and Detectors · Physics 2026-01-12 Faeq Abed , Asmaa AlMellah , Kareem Al-Jubouri , Alex Lumoski

Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be…

Silicon Photomultipliers (SiPMs) are considered as a solid-state sensor alternative to photomultiplier tubes in experiments using liquid xenon (LXe) as a radiation detection medium. The main requirements are single-photon detection of the…

Instrumentation and Detectors · Physics 2018-11-14 Laura Baudis , Michelle Galloway , Alexander Kish , Chris Marentini , Julien Wulf

Next generation multi-ton scale noble liquid experiments have the unique opportunity to discover dark matter particles at the TeV scale, reaching the sensitivity of 10^-48 cm2 in the WIMP nucleon scattering cross-section. A prerequisite…

Instrumentation and Detectors · Physics 2016-01-07 S. Catalanotti , A. G. Cocco , G. Covone , M. D Incecco , G. Fiorillo , G. Korga , B. Rossi , S. Walker

The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect…

Instrumentation and Detectors · Physics 2025-05-22 S. Borden , J. A. Detwiler , W. Pettus , N. W. Ruof

Coherent scattering is a flavor-blind, high-rate, as yet undetected neutrino interaction predicted by the Standard Model. We propose to use a compact (kg-scale), two-phase (liquid-gas) argon ionization detector to measure coherent neutrino…

Nuclear Experiment · Physics 2009-11-10 Chris Hagmann , Adam Bernstein

The ARAPUCA is a novel concept for liquid argon scintillation light detection which has been proposed for the photon detection system of the Deep Underground Neutrino Experiment. The test in liquid argon of one of the first ARAPUCA…

We propose to measure the coherent elastic neutrino nucleus scattering (CE$\nu$NS) using a dual-phase liquid argon time projection chamber (TPC) with 200kg fiducial mass. The detector is expected to be adjacent to the JUNO-TAO experiment…

High Energy Physics - Experiment · Physics 2021-03-22 Yu-Ting Wei , Meng-Yun Guan , Jin-Chang Liu , Ze-Yuan Yu , Chang-Gen Yang , Cong Guo , Wei-Xing Xiong , You-Yu Gan , Qin Zhao , Jia-Jun Li

Large (up to $\sim 100$ kt) liquid argon time-projection chamber detectors are presently being considered for proton decay searches and neutrino astrophysics, as well as for far detectors for the next generation of long-baseline neutrino…

Instrumentation and Detectors · Physics 2015-06-16 Alberto Marchionni

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10~kg of liquid argon. A dark-count characterization technique, which avoids…

This paper describes the results of a study on the general lines, main construction criteria, crucial points, parameters and required preliminary R&D activities for the construction of a LAr (liquid argon) imaging detector with active mass…

Astrophysics · Physics 2007-05-23 D. B. Cline , F. Sergiampietri
‹ Prev 1 2 3 10 Next ›