Related papers: Study of Beam Loss Monitors (BLM) in Storage Ring
The Electron-Muon Ranger (EMR) is a fully-active tracking-calorimeter in charge of the electron background rejection downstream of the cooling channel at the international Muon Ionization Cooling Experiment. It consists of 2832 plastic…
Beam loss is a critical issue in high-intensity accelerators, and much effort is expended during both the design and operation phases to minimize the loss and to keep it to manageable levels. As new accelerators become ever more powerful,…
The K-long and muon detector (KLM) constitutes the outer-most volume of the Belle II spectrometer at the interaction region of the SuperKEKB collider in Tsukuba, Japan. The KLM detector was partially upgraded since the Belle experiment by…
As part of the spin physics program at Jefferson Laboratory (JLab), a M\o ller polarimeter was developed to measure the polarization of electron beam of energies 0.8 to 5.0 GeV. A unique signature for M\o ller scattering is obtained using a…
The GLAST Burst Monitor (GBM) will augment the capabilities of GLAST for the detection of cosmic gamma-ray bursts by extending the energy range (20 MeV to > 300 GeV) of the Large Area Telescope (LAT) towards lower energies by 2…
The PIP2IT accelerator was assembled in multiple stages in 2014 - 2021 to test concepts and components of the future PIP-II linac that is being constructed at Fermilab. In its final configuration, PIP2IT accelerated a 0.55 ms x 20 Hz x 2 mA…
Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The "standard" EL mechanism…
The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring…
We present a quantum optics-based detection method for determining the position and current of an electron beam. As electrons pass through a dilute vapor of rubidium atoms, their magnetic field perturb the atomic spin's quantum state and…
Optical beam center position on an array of detectors is an important (hidden) parameter that is essential not only from a tracking perspective, but is also important for optimal detection of Pulse Position Modulation symbols in free-space…
Radiation damage of J-series silicon photomultipliers (SiPMs) has been studied in the context of using these photodetectors in future space-borne scintillation detectors. Several SiPM samples were exposed to 101.4 MeV protons, with 1 MeV…
Optimization of blade type X-ray Beam Position Monitors (XBPM) was performed for NSLS-II undulator IVU20. Blade material, configuration and operation principle was analyzed to improve XBPM performance. Optimization is based on calculation…
Light yield and spatial uniformity for a large variety of configurations of scintillator tiles was studied. The light from each scintillator was collected by a Silicon Photomultiplier (SiPM) directly viewing the produced scintillation light…
We report on the SuperKEKB Phase I operations of the Large Angle Beamstrhalung Monitor (LABM). The detector is described and its performance characterized using the synchrotron radiation backgrounds from the last Beam Line magnets. The…
In this paper, we employ an electron beam writer as metrology tool to investigate distortion of an exposed pattern of alignment marks in heterogeneously bonded InP on silicon. After experimental study of three different bonding and…
A series of beam tests were conducted at the KEK AR test beamline in ordet to investigate the performance of a prototype detector for instrumentation in the low-E beamline at the CERN H2 line. For the silicon strip detector, the…
We present a new design of highly specialized small storage rings for low energy polarized electron beams. The new design is based on the transparent spin methodology that cancels the spin precession due to the magnetic dipole moment at any…
We report on a beam test of a Silicon Photo-Multiplier (SiPM)-on-tile Zero Degree Calorimeter (ZDC) prototype developed for the future Electron-Ion Collider (EIC). The detector implements the staggered scintillator-tile geometry envisioned…
The energy-spread of the triple-pulse electron beam generated by the Dragon-II linear induction accelerator is measured using the method of energy dispersion in the magnetic field. A sector magnet is applied for energy analyzing of the…
Precision measurements of the electron's electric dipole moment (eEDM) are critical for testing fundamental symmetries in particle physics, and heavy polar molecules-such as barium monofluoride (BaF)-have emerged as promising candidates for…