English
Related papers

Related papers: Observables for Recoil Identification in High-Defi…

200 papers

The viability of using a Bubble Chamber for rare event searches and in particular for the detection of dark matter particle candidates is considered. Techniques leading to the deactivation of inhomogeneous nucleation centers and subsequent…

Gas detectors are one of the pillars of the research in fundamental physics. Since many years, a new concept of detectors, the Micro Pattern Gas Detectors, allows to overcome many of the problems of other types of commonly used detectors,…

In experiments searching for rare signals, background events from the detector itself are some of the major factors limiting search sensitivity.Screening for ultra-low radioactive detector materials is becoming ever more essential. We…

Instrumentation and Detectors · Physics 2021-12-24 Haiyan Du , Chengbo Du , Karl Giboni , Ke Han , Shengming He , Liqiang Liu , Yue Meng , Shaobo Wang , Tao Zhang , Li Zhao , Jifang Zhou

We propose a method to identify the direction of an incident Weakly Interacting Massive Particle (WIMP) via induced nuclear recoil. Our method is based on spectroscopic interrogation of quantum defects in macroscopic solid-state crystals .…

High Energy Physics - Phenomenology · Physics 2017-08-23 Surjeet Rajendran , Nicholas Zobrist , Alexander O. Sushkov , Ronald Walsworth , Mikhail Lukin

Scenarios where dark matter is boosted to relativistic velocities provide a promising probe of sub-GeV dark matter. Cosmic-ray upscattered and supernova-produced dark matter generate relativistic fluxes peaked toward the Galactic Centre, an…

High Energy Physics - Phenomenology · Physics 2026-03-12 Nicole F. Bell , Chiara Lisotti , Jayden L. Newstead , Ciaran A. J. O'Hare , Iman Shaukat Ali

Directional sensitivity is one of the most important aspects of WIMP dark matter searches. Yet, making the direction of nuclear recoil visible with large target masses is a challenge. To achieve this, we are exploring a new method of…

Instrumentation and Detectors · Physics 2015-12-09 Y. Nakajima , A. Goldschmidt , M. Long , D. Nygren , C. Oliveira , J. Renner

MIMAC (MIcro-TPC MAtrix of Chambers) is a directional WIMP Dark Matter detector project. Direct dark matter experiments need a high level of electron/recoil discrimination to search for nuclear recoils produced by WIMP-nucleus elastic…

Instrumentation and Methods for Astrophysics · Physics 2016-09-21 Q. Riffard , D. Santos , O. Guillaudin , G. Bosson , O. Bourrion , J. Bouvier , T. Descombes , J. -F. Muraz , L. Lebreton , D. Maire , P. Colas , I. Giomataris , J. Busto , D. Fouchez , J. Brunner , C. Tao

Astrophysical dark matter particles with masses well below GeV-scale can be difficult to detect using conventional nuclear recoil experiments due to their low velocities in our Milky Way halo. Elastic scattering with high-energy cosmic rays…

High Energy Physics - Phenomenology · Physics 2026-04-21 Xiaoyong Chu , Yue-Lin Sming Tsai , Mei-Wen Yang

Directional detection is a promising direct Dark Matter (DM) search strategy. The angular distribution of the nuclear recoil tracks from WIMP events should present an anisotropy in galactic coordinates. This strategy requires both a…

Instrumentation and Methods for Astrophysics · Physics 2013-06-19 Q. Riffard , J. Billard , G. Bosson , O. Bourrion , O. Guillaudin , J. Lamblin , F. Mayet , J. -F. Muraz , J. -P. Richer , D. Santos , L. Lebreton , D. Maire , J. Busto , J. Brunner , D. Fouchez

The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing a low pressure gas TPC for detecting Weakly Interacting Massive Particle (WIMP)-nucleon interactions. Optical readout with CCD cameras allows for the detection of…

Directional dark matter detection attempts to measure the direction of motion of nuclei recoiling after having interacted with dark matter particles in the halo of our Galaxy. Due to Earth's motion with respect to the Galaxy, the dark…

Cosmology and Nongalactic Astrophysics · Physics 2017-02-01 Nassim Bozorgnia , Graciela B. Gelmini , Paolo Gondolo

MITPC is a gas-based time projection chamber used for detecting fast, MeV-scale neutrons. The standard version of the detector relies on a mixture of 600~torr gas composed of 87.5% $^4$He and 12.5% CF$_4$ for precisely measuring the energy…

Instrumentation and Detectors · Physics 2015-12-09 A. Hexley , M. H. Moulai , J. Spitz , J. M. Conrad

The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical readout with CCD cameras allows for the detection for the daily modulation in the…

Over the past decades, several ideas and technologies have been developed to directly detect WIMP from the galactic halo. All these detection strategies share the common goal of discriminating a WIMP signal from the residual backgrounds. By…

Instrumentation and Detectors · Physics 2015-06-23 J. Billard

Detecting the topology and direction of low-energy nuclear and electronic recoils is broadly desirable in nuclear and particle physics, with applications in coherent elastic neutrino-nucleus scattering, astrophysical neutrino measurements,…

Instrumentation and Detectors · Physics 2024-12-31 Majd Ghrear , Alasdair G. McLean , Hima B. Korandla , Ferdos Dastgiri , Neil J. C. Spooner , Sven E. Vahsen

The emission of $\gamma$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus…

A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils for the purpose of measuring exclusive nuclear reactions, such as coherent Deeply Virtual Compton Scattering and…

Nowadays there is compelling evidence for the existence of dark matter in the Universe. A general consensus has been expressed on the need for a directional sensitive detector to confirm, with a complementary approach, the candidates found…

We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment.…