In this article, we present a new methodology to identify if forced oscillation sources are generated in excitation systems or in turbine governors. In this context, we propose to harness the information that the dynamic state estimation…
The smart grid revolution is creating a paradigm shift in distribution networks that is marked by new, significant intermittencies and uncertainties in power supply and demand. These developments include the dramatic increase in the…
In this work, a novel predictive maintenance system is presented and applied to the main components of wind turbines. The proposed model is based on machine learning and statistical process control tools applied to SCADA (Supervisory…
Accurate fault location is essential for operational reliability and fast restoration in wind farm collector networks. However, the growing integration of inverter-based resources changes the current and voltage behavior during faults,…
The statistical characterization of the measurement errors of a phasor measurement unit (PMU) is currently receiving considerable interest in the power systems community. This paper focuses on the characteristics of the errors in magnitude…
Phasor Measurement Unit (PMU) technology is increasingly used for real-time monitoring applications, especially line outage detection and identification (D&I) in the power system. Current outage D&I schemes either assume a full PMU…
Dynamic state and parameter estimation methods for dynamic security assessment in power systems are becoming increasingly important for system operators. Usually, the data used for this type of applications stems from phasor measurement…
Model predictive control (MPC) has proven its applicability in power conversion control with its fast dynamic response to reference changes while ensuring critical system constraints are satisfied. Even then, the computational burden still…
Forced oscillations are caused by sustained cyclic disturbances. This paper presents a machine learning (ML) based time-series classification method that uses the synchrophasor measurements to locate the sources of forced oscillations for…
This paper describes a new approach for using changepoint detection (CPD) to estimate the starting and stopping times of a forced oscillation (FO) in measured power system data. As with a previous application of CPD to this problem, the…
Phasor Measurement Units (PMUs) are being used extensively for electrical grid monitoring and control. However, their cost prohibits further adoption on the distribution grid and easy access for educational purposes. This paper proposes…
We consider the problem of identifying a single line outage in a power grid by using data from phasor measurement units (PMUs). When a line outage occurs, the voltage phasor of each bus node changes in response to the change in network…
As the distribution grid moves toward a tightly-monitored network, it is important to automate the analysis of the enormous amount of data produced by the sensors to increase the operators situational awareness about the system. In this…
The paper describes a distributed under-frequency load shedding and load restoration scheme, that exploits frequency and Rate-of-Change-of-Frequency (ROCOF) measurements produced by Phasor Measurement Units (PMUs) as detectors of a large…
This study explores the effectiveness of predictive maintenance models and the optimization of intelligent Operation and Maintenance (O&M) systems in improving wind power generation efficiency. Through qualitative research, structured…
A cornerstone of the smart grid is the advanced monitorability on its assets and operations. Increasingly pervasive installation of the phasor measurement units (PMUs) allows the so-called synchrophasor measurements to be taken roughly 100…
The communication control delay between the inverters and the power plant controller can be caused by several factors related to the communication link between them. Under undesirable conditions, high delay values can produce oscillations…
With the support of Internet of Things (IoT) devices, it is possible to acquire data from degradation phenomena and design data-driven models to perform anomaly detection in industrial equipment. This approach not only identifies potential…
The widespread integration of new technologies in low-voltage distribution networks on the consumer side creates the need for distribution system operators to perform advanced real-time calculations to estimate network conditions. In recent…