English
Related papers

Related papers: Complementary Time-Frequency Domain Networks for D…

200 papers

Image reconstruction from undersampled k-space data plays an important role in accelerating the acquisition of MR data, and a lot of deep learning-based methods have been exploited recently. Despite the achieved inspiring results, the…

Computer Vision and Pattern Recognition · Computer Science 2021-09-28 Chen Hu , Cheng Li , Haifeng Wang , Qiegen Liu , Hairong Zheng , Shanshan Wang

Magnetic resonance (MR) image acquisition is an inherently prolonged process, whose acceleration has long been the subject of research. This is commonly achieved by obtaining multiple undersampled images, simultaneously, through parallel…

Image and Video Processing · Electrical Eng. & Systems 2021-06-15 Chun-Mei Feng , Zhanyuan Yang , Huazhu Fu , Yong Xu , Jian Yang , Ling Shao

The goal of dynamic magnetic resonance imaging (dynamic MRI) is to visualize tissue properties and their local changes over time that are traceable in the MR signal. We propose a new variational approach for the reconstruction of subsampled…

Parallel imaging techniques reduce magnetic resonance imaging (MRI) scan time but image quality degrades as the acceleration factor increases. In clinical practice, conservative acceleration factors are chosen because no mechanism exists to…

Image and Video Processing · Electrical Eng. & Systems 2026-05-26 Ilias I. Giannakopoulos , Lokesh B Gautham Muthukumar , Yvonne W. Lui , Riccardo Lattanzi

Conventional cardiac cine MRI methods rely on retrospective gating, which limits temporal resolution and the ability to capture continuous cardiac dynamics, particularly in patients with arrhythmias and beat-to-beat variations. To address…

Image and Video Processing · Electrical Eng. & Systems 2024-12-18 Wenqi Huang , Veronika Spieker , Siying Xu , Gastao Cruz , Claudia Prieto , Julia Schnabel , Kerstin Hammernik , Thomas Kuestner , Daniel Rueckert

Magnetic resonance imaging (MRI) is known to be a slow imaging modality and undersampling in k-space has been used to increase the imaging speed. However, image reconstruction from undersampled k-space data is an ill-posed inverse problem.…

Image and Video Processing · Electrical Eng. & Systems 2019-08-08 Jing Cheng , Haifeng Wang , Leslie Ying , Dong Liang

Cine Magnetic Resonance Imaging (MRI) allows for understanding of the heart's function and condition in a non-invasive manner. Undersampling of the $k$-space is employed to reduce the scan duration, thus increasing patient comfort and…

Image and Video Processing · Electrical Eng. & Systems 2024-02-13 Yuyang Xue , Yuning Du , Gianluca Carloni , Eva Pachetti , Connor Jordan , Sotirios A. Tsaftaris

We propose neural network layers that explicitly combine frequency and image feature representations and show that they can be used as a versatile building block for reconstruction from frequency space data. Our work is motivated by the…

Computer Vision and Pattern Recognition · Computer Science 2023-06-29 Nalini M. Singh , Juan Eugenio Iglesias , Elfar Adalsteinsson , Adrian V. Dalca , Polina Golland

Current deep learning reconstruction for accelerated cardiac cine MRI suffers from spatial and temporal blurring. We aim to improve image sharpness and motion delineation for cine MRI under high undersampling rates. A spatiotemporal…

Image and Video Processing · Electrical Eng. & Systems 2024-03-14 Shihan Qiu , Shaoyan Pan , Yikang Liu , Lin Zhao , Jian Xu , Qi Liu , Terrence Chen , Eric Z. Chen , Xiao Chen , Shanhui Sun

This study introduces a novel approach for image reconstruction based on a diffusion model conditioned on the native data domain. Our method is applied to multi-coil MRI and quantitative MRI reconstruction, leveraging the domain-conditioned…

Machine Learning · Computer Science 2023-09-06 Wanyu Bian , Albert Jang , Fang Liu

Cardiac cine MRI is the gold standard for cardiac functional assessment, but the inherently slow acquisition process creates the necessity of reconstruction approaches for accelerated undersampled acquisitions. Several regularization…

Image and Video Processing · Electrical Eng. & Systems 2023-07-28 Tabita Catalán , Matías Courdurier , Axel Osses , René Botnar , Francisco Sahli Costabal , Claudia Prieto

Cine cardiac magnetic resonance imaging (MRI) is widely used for diagnosis of cardiac diseases thanks to its ability to present cardiovascular features in excellent contrast. As compared to computed tomography (CT), MRI, however, requires a…

Image and Video Processing · Electrical Eng. & Systems 2020-06-24 Qing Lyu , Hongming Shan , Yibin Xie , Debiao Li , Ge Wang

Long scan time significantly hinders the widespread applications of three-dimensional multi-contrast cardiac magnetic resonance (3D-MC-CMR) imaging. This study aims to accelerate 3D-MC-CMR acquisition by a novel method based on score-based…

Signal Processing · Electrical Eng. & Systems 2024-10-29 Yuanyuan Liu , Zhuo-Xu Cui , Shucong Qin , Congcong Liu , Hairong Zheng , Haifeng Wang , Yihang Zhou , Dong Liang , Yanjie Zhu

Parallel MRI is a fast imaging technique that enables the acquisition of highly resolved images in space. It relies on $k$-space undersampling and multiple receiver coils with complementary sensitivity profiles in order to reconstruct a…

A joint image reconstruction and segmentation approach based on disentangled representation learning was trained to enable cardiac cine MR imaging in real-time and under free-breathing. An exploratory feasibility study tested the proposed…

Purpose: To accelerate MRI acquisition by incorporating the previous scans of a subject during reconstruction. Although longitudinal imaging constitutes much of clinical MRI, leveraging previous scans is challenging due to the complex…

Image and Video Processing · Electrical Eng. & Systems 2025-10-21 Yonatan Urman , Zachary Shah , Ashwin Kumar , Bruno P. Soares , Kawin Setsompop

Fast and accurate reconstruction of magnetic resonance (MR) images from under-sampled data is important in many clinical applications. In recent years, deep learning-based methods have been shown to produce superior performance on MR image…

Image and Video Processing · Electrical Eng. & Systems 2021-03-12 Pengfei Guo , Puyang Wang , Jinyuan Zhou , Shanshan Jiang , Vishal M. Patel

Parallel imaging is a widely-used technique to accelerate magnetic resonance imaging (MRI). However, current methods still perform poorly in reconstructing artifact-free MRI images from highly undersampled k-space data. Recently, implicit…

Image and Video Processing · Electrical Eng. & Systems 2022-10-20 Ruimin Feng , Qing Wu , Yuyao Zhang , Hongjiang Wei

Cine cardiac MRI is routinely acquired for the assessment of cardiac health, but the imaging process is slow and typically requires several breath-holds to acquire sufficient k-space profiles to ensure good image quality. Several…

Low-dose Computed Tomography is a common issue in reality. Current reduction, sparse sampling and limited-view scanning can all cause it. Between them, limited-view CT is general in the industry due to inevitable mechanical and physical…

Image and Video Processing · Electrical Eng. & Systems 2021-01-20 Ken Deng , Chang Sun , Yitong Liu , Hongwen Yang