English
Related papers

Related papers: Positional Dependence of Pulse Shape Discriminatio…

200 papers

The light output, $\alpha/\beta$ ratio, and pulse shape have been investigated at $-25^\circ$ C with PbWO$_4$ crystal scintillators undoped, and doped by F, Eu, Mo, Gd and S. The fast $0.01-0.06 \mu$s and middle $0.1-0.5 \mu$s components of…

The success of the various secondary operations involved in the production of particulate products depends on the production of particles with a desired size and shape from a previous primary operation such as crystallisation. This is…

We report on the spatial response characterization of large LaCl$_{3}$(Ce) monolithic crystals optically coupled to 8$\times$8 pixel silicon photomultiplier (SiPM) sensors. A systematic study has been carried out for 511 keV $\gamma$-rays…

Instrumentation and Detectors · Physics 2019-04-17 Victor Babiano , Luis Caballero , David Calvo , Ion Ladarescu , Pablo Olleros , César Domingo-Pardo

Pulse Shape Discrimination (PSD) is a widely used technique in many experimental analysis. In this study, we specifically aimed to assess the effectiveness of PSD in accurately measuring decay time. We measured the decay times of a 0.1 wt%…

High Energy Physics - Experiment · Physics 2024-10-29 S. B. Hong , J. S. Park

Pulsar scintillation allows a glimpse into small-scale plasma structures in the interstellar medium, if we can infer their properties from the scintillation pattern. With Very Long Baseline Interferometry and working in delay-delay rate…

Instrumentation and Methods for Astrophysics · Physics 2019-08-07 Dana Simard , Ue-Li Pen , Visweshwar Ram Marthi , Walter Brisken

In this paper, we express the Chord Length Distribution (CLD) measure associated to a given Particle Size Distribution (PSD) when particles are modeled as suspended spheroids in a reactor. Using this approach, we propose two methods to…

Optimization and Control · Mathematics 2020-12-16 Lucas Brivadis , Ludovic Sacchelli

In beam test experiments have been carried out for particle identification using digital pulse shape analysis in a 500~$\mu$m thick Neutron Transmutation Doped (nTD) silicon detector with an indigenously developed FPGA based 12 bit…

Instrumentation and Detectors · Physics 2018-05-09 K. Mahata , A. Shrivastava , J. A. Gore , S. K. Pandit , V. V. Parkar , K. Ramachandran , A. Kumar , S. Gupta , P. Patale

Plastic scintillation detectors are increasingly used to measure dose distributions in the context of radiotherapy treatments. Their water-equivalence, real-time response and high spatial resolution distinguish them from traditional…

Medical Physics · Physics 2021-09-22 Emily Cloutier , Louis Archambault , Luc Beaulieu

This paper reports a series of measurements that characterize the directional dependence of the scintillation response of crystalline melt-grown and solution-grown stilbene to incident DT and DD neutrons. These measurements give the…

Instrumentation and Detectors · Physics 2017-06-07 Patricia Schuster , Erik Brubaker

In this paper, we are interested in the estimation of Particle Size Distributions (PSDs) during a batch crystallization process in which particles of two different shapes coexist and evolve simultaneously. The PSDs are estimated thanks to a…

Optimization and Control · Mathematics 2021-03-23 Lucas Brivadis , Ludovic Sacchelli

Pulse shape discrimination with pure CsI scintillators is investigated as a method for separating energy deposits by energetic neutrons and photons at particle physics experiments. Using neutron data collected near the European XFEL XS1…

Instrumentation and Detectors · Physics 2022-07-11 S. Longo , M. Khan , S. Dharani , B. von Krosigk , T. Ferber

This work describes a class of liquid scintillators that contain mostly water (>50 wt. % of the entire composition) and can discriminate between interactions induced by neutrons and gamma rays. By balancing the interface interactions…

We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 $\times$ 8 array of plastic scintillator segments coupled to two 5 cm $\times$ 5 cm 64-channel SiPM arrays as part of a study of…

Localisation of gamma-ray interaction points in monolithic scintillator crystals can simplify the design and improve the performance of a future Compton telescope for gamma-ray astronomy. In this paper we compare the position resolution of…

Instrumentation and Methods for Astrophysics · Physics 2017-01-20 Alexei Ulyanov , Oran Morris , Oliver J. Roberts , Isaac Tobin , Lorraine Hanlon , Sheila McBreen , David Murphy , Nick Nelms , Brian Shortt

Purpose: This study aims to optimize and characterize the response of a mPSD for in vivo dosimetry in HDR brachytherapy. Methods: An exhaustive analysis was carried out in order to obtain an optimized mPSD design that maximize the…

The Plastic Scintillator Detector (PSD) of the DArk Matter Particle Explorer (DAMPE) is designed to measure cosmic ray charge (Z) and to act as a veto detector for gamma-ray identification. In order to fully exploit the charge…

Instrumentation and Methods for Astrophysics · Physics 2019-06-19 Peng-Xiong Ma , Yong-Jie Zhang , Ya-Peng Zhang , Yao Li , Jing-Jing Zang , Xiang Li , Tie-Kuang Dong , Yi-Zhong Fan , Shi-Jun Lei , Jian Wu , Yu-Hong Yu , Qiang Yuan , Chuan Yue , Zhi-Yu Sun

The energy and electric field dependence of pulse shape discrimination in liquid xenon have been measured in a 10 gm two-phase xenon time projection chamber. We have demonstrated the use of the pulse shape and charge-to-light ratio…

Instrumentation and Methods for Astrophysics · Physics 2015-05-13 J. Kwong , P. Brusov , T. Shutt , C. E. Dahl , A. I. Bolozdynya , A. Bradley

The first domestic inorganic scintillator CLYC was grown in Beijing Glass Research Instituteusing the vertical Bridgman method. In this work, we evaluated the performance of this new CLYC crystal in terms of gamma-ray energy resolution and…

Instrumentation and Detectors · Physics 2016-09-01 Li Kui-Nian , Zhang Xian-Peng , Gui Qiang , Jin Peng , Tian Geng

This paper is devoted to the study of a degradation of CsI(Tl)crystals scintillation characteristics under irradiation with gamma-quanta at the uniformly distributed absorbed dose up to 3700 rad. The sample set consisted of 25 crystals of…

Instrumentation and Detectors · Physics 2009-11-10 D. M. Beylin , A. I. Korchagin , A. S. Kuzmin , L. M. Kurdadze , S. B. Oreshkin , S. E. Petrov , B. A. Shwartz