English
Related papers

Related papers: Automatic image-based respiratory signal extractio…

200 papers

Respiratory diseases remain a leading cause of mortality worldwide, highlighting the need for faster and more accurate diagnostic tools. This work presents a novel approach leveraging digital stethoscope technology for automatic respiratory…

Signal Processing · Electrical Eng. & Systems 2024-03-19 Constantino Álvarez Casado , Manuel Lage Cañellas , Matteo Pedone , Xiaoting Wu , Le Nguyen , Miguel Bordallo López

Background: The trend towards large-scale studies including population imaging poses new challenges in terms of quality control (QC). This is a particular issue when automatic processing tools, e.g. image segmentation methods, are employed…

Background: Accelerated real-time cine (RT-Cine) imaging enables cardiac function assessment without the need for breath-holding. However, when performed during in-magnet exercise, RT-Cine images may exhibit significant motion artifacts.…

Signal Processing · Electrical Eng. & Systems 2024-05-28 Chong Chen , Yingmin Liu , Yu Ding , Matthew Tong , Preethi Chandrasekaran , Christopher Crabtree , Syed M. Arshad , Yuchi Han , Rizwan Ahmad

Motion free reconstruction of compressively sampled cardiac perfusion MR images is a challenging problem. It is due to the aliasing artifacts and the rapid contrast changes in the reconstructed perfusion images. In addition to the…

Image and Video Processing · Electrical Eng. & Systems 2019-04-11 Abdul Haseeb Ahmed , Ijaz M. Qureshi

The effectiveness of a cardiovascular magnetic resonance (CMR) scan depends on the ability of the operator to correctly tune the acquisition parameters to the subject being scanned and on the potential occurrence of imaging artefacts such…

Cardiovascular magnetic resonance (CMR) imaging is a standard imaging modality for assessing cardiovascular diseases (CVDs), the leading cause of death globally. CMR enables accurate quantification of the cardiac chamber volume, ejection…

Estimating human vital signs in a contactless non-invasive method using radar provides a convenient method in the medical field to conduct several health checkups easily and quickly. In addition to monitoring while sitting and sleeping, the…

Signal Processing · Electrical Eng. & Systems 2022-06-14 Tassneem Helal , Fady Aziz , Omar Metwally , Marco F. Huber , Dominik Alscher , Christoph Wasser , Urs Schneider

Cardiac magnetic resonance (CMR) image acquisition requires subjects to hold their breath while 2D cine images are acquired. This process assumes that the heart remains in the same position across all slices. However, differences in…

Image and Video Processing · Electrical Eng. & Systems 2024-04-02 Nil Stolt-Ansó , Vasiliki Sideri-Lampretsa , Maik Dannecker , Daniel Rueckert

Respiratory-gated radiation therapy (RGRT) has been used to minimize the dose to normal tissue in lung-cancer radiotherapy. The present research aims to improve the regularity of respiration in RGRT using a video coached respiration guiding…

Medical Physics · Physics 2015-03-13 Hyun Jeong Lee , Ji Woon Yea , Se An Oh

Due to the prolonged MRI encoding process, respiratory motion can cause undesired artifacts and image blurring, degrading image quality and limiting clinical applications in abdominal and pulmonary imaging. In this work, we develop a…

Purpose: To develop a respiratory-resolved motion-compensation method for free-breathing, high-resolution coronary magnetic resonance angiography using a 3D cones trajectory. Methods: To achieve respiratory-resolved 0.98 mm resolution…

Deviations in respiratory rate often precede abnormalities in other vital signs. However, continuously monitoring respiratory rates outside clinical settings remains challenging due to the obtrusive nature and sensitivity to body motions in…

Signal Processing · Electrical Eng. & Systems 2024-11-15 Sebastian Reidy , Manuel Meier , Christian Holz

Monitoring respiratory health with the use of channel state information (CSI) has shown promising results. Many existing methods focus on monitoring only the respiratory rate, while others focus on monitoring the motion of the chest as a…

Emerging Technologies · Computer Science 2025-08-01 James Rhodes , Lawrence Ong , Duy T. Ngo

Respiratory rate (RR) is a clinical metric used to assess overall health and physical fitness. An individual's RR can change from their baseline due to chronic illness symptoms (e.g., asthma, congestive heart failure), acute illness (e.g.,…

Sound · Computer Science 2021-07-30 Agni Kumar , Vikramjit Mitra , Carolyn Oliver , Adeeti Ullal , Matt Biddulph , Irida Mance

Cardiac Magnetic Resonance Imaging (CMR) is widely used since it can illustrate the structure and function of heart in a non-invasive and painless way. However, it is time-consuming and high-cost to acquire the high-quality scans due to the…

Image and Video Processing · Electrical Eng. & Systems 2020-07-09 Jhih-Yuan Lin , Yu-Cheng Chang , Winston H. Hsu

The lack of large video databases obtained from real patients with respiratory disorders makes the design and optimization of video-based monitoring systems quite critical. The purpose of this study is the development of suitable models and…

Applications · Statistics 2023-07-14 Davide Alinovi , Gianluigi Ferrari , Francesco Pisani , Riccardo Raheli

Respiratory ailments afflict a wide range of people and manifests itself through conditions like asthma and sleep apnea. Continuous monitoring of chronic respiratory ailments is seldom used outside the intensive care ward due to the large…

This study proposes an accurate method to estimate human body orientation using a millimeter-wave radar system. Body displacement is measured from the phase of the radar echo, which is analyzed to obtain features associated with the…

Signal Processing · Electrical Eng. & Systems 2023-07-19 Wenxu Sun , Shunsuke Iwata , Yuji Tanaka , Takuya Sakamoto

Cardiac magnetic resonance imaging improves on diagnosis of cardiovascular diseases by providing images at high spatiotemporal resolution. Manual evaluation of these time-series, however, is expensive and prone to biased and…

Computer Vision and Pattern Recognition · Computer Science 2018-04-06 Fabian Isensee , Paul Jaeger , Peter M. Full , Ivo Wolf , Sandy Engelhardt , Klaus H. Maier-Hein

Cardiac Magnetic Resonance Imaging (MRI) is time-consuming and error-prone. To ease the patient's burden and to increase the efficiency and robustness of cardiac exams, interest in methods based on continuous steady-state acquisition and…

Medical Physics · Physics 2020-10-06 Sebastian Rosenzweig , Nick Scholand , H. Christian M. Holme , Martin Uecker