English
Related papers

Related papers: Parametric resonance magnetometer based on ellipti…

200 papers

The operation of a high sensitive atomic magnetometer using resonant elliptically polarized light is demonstrated. The experimental geometry allows autonomous frequency stabilization of the laser, thereby offers compact operation of the…

Atomic Physics · Physics 2016-03-23 S. Pradhan , S. Mishra , R. Behera , Poornima , K. Dasgupta

Optically pumped magnetometers usually rely on optical pumping using circularly- or linearly-polarized light. We study here zero-field magnetometers pumped with elliptically-polarized light, preparing both atomic orientation and alignment…

Atomic Physics · Physics 2022-05-04 Gwenael Le Gal , Agustin Palacios-Laloy

The three axis magnetic field measurement based on the interaction of a single elliptically polarized light beam with an atomic system is described. The magnetic field direction dependent atomic responses are extracted by the polarimetric…

Instrumentation and Detectors · Physics 2016-09-21 Swarupananda Pradhan

We study a resonant interaction of an elliptically polarized light wave with $^{87}$Rb vapor (D$_1$ line) exposed to a transverse magnetic field. A $5$$\times$$5$$\times$$5$~mm$^3$ glass vapor cell is used for the experiments. The wave…

We present an experimental study of the intrinsic magnetometric sensitivity of an optical/rf-frequency double resonance magnetometer in which linearly polarized laser light is used in the optical pumping and detection processes. We show…

Atomic Physics · Physics 2009-11-13 G. Di Domenico , H. Saudan , G. Bison , P. Knowles , A. Weis

An atomic magnetometer operated with elliptically polarized light is investigated theoretically and experimentally. To explore the potential of this magnetometric configuration, the analytical form of the outgoing signal is derived.…

Atomic Physics · Physics 2020-01-08 Shengran Su , Guoyi Zhang , Xin Bi , Xiang He , Wenqiang Zheng , Qiang Lin

Double-resonance optically pumped magnetometers are an attractive instrument for unshielded magnetic field measurements due to their wide dynamic range and high sensitivity. Use of linearly polarised pump light creates alignment in the…

Atomic Physics · Physics 2018-09-26 Stuart J. Ingleby , Carolyn O'Dwyer , Paul F. Griffin , Aidan S. Arnold , Erling Riis

The operation of polarimetric based single beam three axis atomic magnetometer is studied. The magnetometer operates in presence of small bias magnetic field. Its salient features are compared with the analysis of Bloch equation. The…

Atomic Physics · Physics 2019-03-18 Swarupananda Pradhan , Rita Behera

The paper investigates the ellipsometric method of measuring the magneto-optical parameter and optical constants in one experiment at affixed angle of the light incidence in ferromagnetics. The influence of the magnetization modulation on…

Optics · Physics 2009-09-17 Otar Bakradze* , Zurab Alimbarashvili , Rusiko Janelidze

Double resonance optically pumped magnetometry can be used to measure static magnetic fields with high sensitivity by detecting a resonant atomic spin response to a small oscillating field perturbation. Determination of the resonant…

Atomic Physics · Physics 2017-09-13 Stuart J. Ingleby , Carolyn O'Dwyer , Paul F. Griffin , Aidan S. Arnold , Erling Riis

We present a theoretical study of the spectra produced by optical-radio-frequency double resonance devices, in which resonant linearly polarized light is used in the optical pumping and detection processes. We extend previous work by…

Atomic Physics · Physics 2007-05-23 Antoine Weis , Georg Bison , Anatoly S. Pazgalev

Optically-pumped magnetometers are an important instrument for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of…

Applied Physics · Physics 2024-04-12 Adil Meraki , Lucy Elson , Nok Ho , Ali Akbar , Marcin Koźbiał , Jan Kołodyński , Kasper Jensen

We investigate the ground-state Hanle effect in alkali-metal vapor irradiating by a resonant elliptically polarized light wave. The magneto-optical resonances are observed as a change in the ellipticity parameter of the light wave…

Atomic Physics · Physics 2025-11-25 D. V. Brazhnikov , A. O. Makarov , K. S. Kozlova , A. N. Goncharov

Spin-exchange relaxation free alkali-metal magnetometers typically operate in the regime of high optical density, presenting challenges for simple and efficient optical pumping and detection. We describe a high-sensitivity Rb magnetometer…

Atomic Physics · Physics 2009-03-16 V. Shah , M. V. Romalis

We report on an all-optical magnetometric technique based on nonlinear magneto-optical rotation with amplitude-modulated light. The method enables sensitive magnetic-field measurements in a broad dynamic range. We demonstrate the…

Atomic Physics · Physics 2009-11-13 S. Pustelny , A. Wojciechowski , M. Gring , M. Kotyrba , J. Zachorowski , W. Gawlik

Some of the most sensitive methods of measuring magnetic fields utilize interactions of resonant light with atomic vapor. Recent developments in this vibrant field are improving magnetometers in many traditional areas such as measurement of…

Atomic Physics · Physics 2015-06-26 D. Budker , M. V. Romalis

In this work, we present a comprehensive and comparative analysis of two detection modalities, i.e., polarization rotation and absorption measurement of light, for a double resonance alignment based optical magnetometer (DRAM). We derive…

Optics · Physics 2024-03-11 A. Akbar , M. Kozbiál , L. Elson , A. Meraki , J. Kolodyński , K. Jensen

The parameters of nonlinear absorption magneto-optical resonances in the Hanle configuration have been studied as functions of the ellipticity of a traveling light wave. It has been found that these parameters (amplitude, width, and…

We explore properties of the radio-frequency atomic magnetometer, specifically its sensitivity to the polarisation of an oscillating magnetic field. This aspect can be particularly relevant to configurations where the sensor monitors fields…

Applied Physics · Physics 2024-07-11 L. M. Rushton , L. M. Ellis , J. D. Zipfel , P. Bevington , W. Chalupczak

A magnetometric technique is demonstrated that may be suitable for precision measurements of fields ranging from the sub-microgauss level to above the Earth field. It is based on resonant nonlinear magneto-optical rotation caused by atoms…

Atomic Physics · Physics 2009-11-07 D. Budker , D. F. Kimball , V. V. Yashchuk , M. Zolotorev
‹ Prev 1 2 3 10 Next ›