English
Related papers

Related papers: High-resolution Calorimetry in Pulsed Magnetic Fie…

200 papers

Cellular metabolic rate is a good indicator of the physiological state of cells and its changes, which can be measured by total heat flux accompanying metabolism. Chip calorimeters can provide label-free and high throughput measurements of…

Biological Physics · Physics 2019-03-13 Jihye Kim , Sumin Seo , Jonghyun Kim , Sungmin Nam , Wonhee Lee

This paper presents the development of a high field pulsed magnet system combined with an optical fiber-coupled low temperature cryostat for magneto-photoluminescence measurements. A novel aspect of our system is the use of electrolyte…

Instrumentation and Detectors · Physics 2026-03-17 Deepesh Kalauni , Kingshuk Mukhuti , Tao Peng , Bhavtosh Bansal

We present a novel high resolution contactless technique for thermal conductivity determination and thermal field mapping based on creating a thermal distribution of phonons using a heating laser, while a second laser probes the local…

Heat capacity measurements using the ac steady state method are often considered difficult to provide absolute accuracy. By adjusting the working frequency to maintain a constant phase and using the phase information to obtain the heat…

Superconductivity · Physics 2015-06-04 S. Tagliati , A. Rydh

The investigations of low-temperature heat capacity in pure and impurity doped high temperature superconductors have been performed by high-precision pulsed differential scanning calorimeter, providing the measurements of heat capacities…

Superconductivity · Physics 2012-10-09 M. M. Nadareishvili , K. A. Kvavadze , N. E. Hussey , A. J. Shengelaya , S. J. Tsakadze , J. Ramsden

A specific heat measuring instrument, with the capacity for the application of magnetic fields up to 9 Tesla, resorting to microcalorimetry chips from the company Xensor Integration, has been successfully assembled and its functioning…

Instrumentation and Detectors · Physics 2013-03-20 J. V. Leitao , P. van Dommelen , F. Naastepad , E. Brück

We describe a low-cost and simple setup for hyperthermia measurements on colloidal solutions of magnetic nanoparticles (ferrofluids) with a frequency-adjustable magnetic field in the range 5-500 kHz produced by an electromagnet. By…

Materials Science · Physics 2008-10-09 L. -M. Lacroix , J. Carrey , M. Respaud

The performance of the CMS electromagnetic calorimeter upgraded readout electronics, developed for the High-Luminosity phase of the LHC, is discussed. Data collected in two beam test campaigns conducted in 2018 and 2021 at the H4 and H2…

Instrumentation and Detectors · Physics 2025-11-24 The CMS Electromagnetic Calorimeter Group

The RD52 Project at CERN is a pure instrumentation experiment whose goal is to understand the fundamental limitations to hadronic energy resolution, and other aspects of energy measurement, in high energy calorimeters. We have found that…

We present a one-heater-two-thermometer set-up for measuring thermal conductivity and electric resistivity of a bulk sample at low temperatures down to 0.1 K and in magnetic fields up to 27 Tesla. The design overcomes the difficulties…

Superconductivity · Physics 2009-11-10 P. J. E. M. van der Linden , K. Behnia

The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5x10^{-17} after three years of data taking. The monoenergetic electron produced in…

High cooling power of magnetocaloric refrigeration can be achieved only at large amounts of heat, which can be transferred in one cycle from cold end to hot end at quasi-isothermal conditions. The simple experimental method for direct…

The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $\mu \to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot…

We introduce a calorimetric approach to probe persistent currents in normal metal rings. The heat capacity of a large ensemble of silver rings is measured by nanocalorimetry under a varying magnetic field at different temperatures (60 mK,…

Mesoscale and Nanoscale Physics · Physics 2015-06-12 Germain Souche , Julien Huillery , H. Pothier , Philippe Gandit , Jerome I. Mars , Sergey Skipetrov , Olivier Bourgeois

A calorimetric measurement has recently been proposed as a promising technique to measure thermodynamic quantities in a dissipative superconducting qubit. These measurements rely on the fact that the system is projected into energy…

Quantum Physics · Physics 2016-12-28 Rui Sampaio , Samu Suomela , Tapio Ala-Nissila

An important technological step towards the realization of an ultra-granular hadronic calorimeter to be used in the future International Linear Collider (ILC) experiments has been made. A 33X50 cm2 GRPC detector equipped with a power-pulsed…

Instrumentation and Detectors · Physics 2015-06-03 L. Caponetto , C. Combaret , C. de la Taille , F. Dulucq , R. Kieffer , I. Laktineh , N. Lumb , L. Mirabito , N. Seguin-Moreau

Accurate power measurements of electronic components operating at high frequencies are vital in determining where power losses occur in a system such as a power converter. Such power measurements must be carried out with equipment that can…

Instrumentation and Detectors · Physics 2015-09-10 Damien F. Frost , David A. Howey

A prototype of a new type of calorimeter has been designed and constructed, based on a silicon-tungsten sampling design using pixel sensors with digital readout. It makes use of the Alpide MAPS sensor developed for the ALICE ITS upgrade. A…

A new method of absolute heat capacity measurement was developed in the Department of Biological Systems Physics at the E. Andronikashvili Institute of Physics, Georgian Academy of Sciences. This is the method of absolute heat capacity…

Biological Physics · Physics 2007-05-23 G. Tvauri , N. Bakradze , E. Kiziria

A high granularity hadronic 1 m3 calorimeter prototype with semi-digital readout has been designed and built. This calorimeter has been made using stainless steel as absorber and Glass Resistive Plates Chambers (GRPC) as active medium, and…

Instrumentation and Detectors · Physics 2019-08-13 M. C Fouz