Object: It is increasingly popular to collect as much data as possible in the hospital setting from clinical monitors for research purposes. However, in this setup the data calibration issue is often not discussed and, rather, implicitly…

Quantitative Methods · Quantitative Biology 2019-09-17 Yu-Ting Lin , Yu-Lun Lo , Chen-Yun Lin , Hau-Tieng Wu , Martin G. Frasch

Human heartbeat can be measured using several different ways appropriately based on the patient condition which includes contact base such as measured by using instruments and non-contact base such as computer vision assisted techniques.…

Computer Vision and Pattern Recognition · Computer Science 2020-10-12 Vladislav Ostankovich , Geesara Prathap , Ilya Afanasyev

The electrocardiogram (ECG) has always been an important biomedical test to diagnose cardiovascular diseases. Current approaches for ECG monitoring are based on body attached electrodes leading to uncomfortable user experience. Therefore,…

Signal Processing · Electrical Eng. & Systems 2022-11-22 Jinbo Chen , Dongheng Zhang , Zhi Wu , Fang Zhou , Qibin Sun , Yan Chen

The use of photoplethysmogram signal (PPG) for heart and sleep monitoring is commonly found nowadays in smartphones and wrist wearables. Besides common usages, it has been proposed and reported that person information can be extracted from…

Audio and Speech Processing · Electrical Eng. & Systems 2019-11-13 Guillermo Cámbara , Jordi Luque , Mireia Farrús

Modern smartwatches often include photoplethysmographic (PPG) sensors to measure heartbeats or blood pressure through complex algorithms that fuse PPG data with other signals. In this work, we propose a collaborative inference approach that…

Signal Processing · Electrical Eng. & Systems 2023-06-13 Alessio Burrello , Matteo Risso , Noemi Tomasello , Yukai Chen , Luca Benini , Enrico Macii , Massimo Poncino , Daniele Jahier Pagliari

Portable physiological monitoring is essential for early detection and management of cardiovascular disease, but current methods often require specialized equipment that limits accessibility or impose impractical postures that patients…

Computer Vision and Pattern Recognition · Computer Science 2025-11-05 Jiankai Tang , Tao Zhang , Jia Li , Yiru Zhang , Mingyu Zhang , Kegang Wang , Yuming Hao , Bolin Wang , Haiyang Li , Xingyao Wang , Yuanchun Shi , Yuntao Wang , Sichong Qian

Remote photoplethysmography (rPPG) based on traditional frame-based cameras often struggles with motion artifacts and limited temporal resolution. To address these limitations, we introduce EMPD (Event-based Multimodal Physiological…

Signal Processing · Electrical Eng. & Systems 2026-03-31 Qian Feng , Pengfei Li , Rongshan Gao , Jiale Xu , Rui Gong , Yidi Li

Digital twins for 1D bio-signals enable real-time monitoring of physiological processes of a person, which enables early disease diagnosis and personalized treatment. This work introduces a novel non-contact method for digital twin (DT)…

Vital signs, such as heart rate (HR), heart rate variability (HRV), respiratory rate (RR), are important indicators for a person's health. Vital signs are traditionally measured with contact sensors, and may be inconvenient and cause…

Image and Video Processing · Electrical Eng. & Systems 2019-11-04 Mingliang Chen , Qiang Zhu , Harrison Zhang , Min Wu , Quanzeng Wang

Over the last decade, smartphones have changed radically to support us with mHealth technology, cloud computing, and machine learning algorithm. Having its multifaceted facilities, we present a novel smartphone-based noninvasive hemoglobin…

Image and Video Processing · Electrical Eng. & Systems 2019-10-08 Md Kamrul Hasan , Nazmus Sakib , Joshua Field , Richard R. Love , Sheikh I. Ahamed

Electrocardiography (ECG) is the clinical standard for cardiac assessment but requires dedicated hardware that does not scale to daily-life monitoring. Photoplethysmography (PPG) is ubiquitous in wearables but lacks ECG-specific diagnostic…

Signal Processing · Electrical Eng. & Systems 2026-05-14 Xiaoda Wang , Minxiao Wang , Kaiqiao Han , Defu Cao , Ching Chang , Yidan Shi , Runze Yan , Xiao Luo , Yan Liu , Xiao Hu , Yizhou Sun , Wei Wang , Carl Yang

Today's diagnostics include devices such as pulse oximeters, blood pressure monitors, and temperature measurements. These devices provide vital information to medical personnel when making treatment decisions. Drawing inspiration from the…

Image and Video Processing · Electrical Eng. & Systems 2022-08-26 Akhil Kallepalli , David B James , Mark A Richardson

Hearth Rate (HR) monitoring is increasingly performed in wrist-worn devices using low-cost photoplethysmography (PPG) sensors. However, Motion Artifacts (MAs) caused by movements of the subject's arm affect the performance of PPG-based HR…

Signal Processing · Electrical Eng. & Systems 2022-03-29 Alessio Burrello , Daniele Jahier Pagliari , Matteo Risso , Simone Benatti , Enrico Macii , Luca Benini , Massimo Poncino

Photolethysmographic imaging (PPGI) is a widefield non-contact biophotonic technology able to remotely monitor cardiovascular function over anatomical areas. Though spatial context can provide increased physiological insight, existing PPGI…

Quantitative Methods · Quantitative Biology 2016-12-21 Robert Amelard , David A Clausi , Alexander Wong

In this paper we develop a robust for heart rate (HR) estimation method using face video for challenging scenarios with high variability sources such as head movement, illumination changes, vibration, blur, etc. Our method employs a quality…

Computer Vision and Pattern Recognition · Computer Science 2019-05-21 Javier Hernandez-Ortega , Shigenori Nagae , Julian Fierrez , Aythami Morales

Recent advancements in data-driven approaches for remote photoplethysmography (rPPG) have significantly improved the accuracy of remote heart rate estimation. However, the performance of such approaches worsens considerably under video…

Computer Vision and Pattern Recognition · Computer Science 2024-06-26 Joaquim Comas , Adria Ruiz , Federico Sukno

Wearable physiological monitors are ubiquitous, and photoplethysmography (PPG) is the standard low-cost sensor for measuring cardiac activity. Metrics such as inter-beat interval (IBI) and pulse-rate variability (PRV) -- core markers of…

Other Computer Science · Computer Science 2025-10-08 Yuna Watanabe , Natasha Yamane , Aarti Sathyanarayana , Varun Mishra , Matthew S. Goodwin

Human health can be critically affected by cardiovascular diseases, such as hypertension, arrhythmias, and stroke. Heart rate and blood pressure are important biometric information for the monitoring of cardiovascular system and early…

Computer Vision and Pattern Recognition · Computer Science 2026-05-08 Gyutae Hwang , Sang Jun Lee

Atrial fibrillation (AF) is a prevalent cardiac arrhythmia associated with significant health ramifications, including an elevated susceptibility to ischemic stroke, heart disease, and heightened mortality. Photoplethysmography (PPG) has…

Signal Processing · Electrical Eng. & Systems 2023-10-24 Cheng Ding , Ran Xiao , Weijia Wang , Elizabeth Holdsworth , Xiao Hu

This work explores the feasibility of employing ultrasound (US) US technology in a wrist-worn IoT device for low-power, high-fidelity heart-rate (HR) extraction. US offers deep tissue penetration and can monitor pulsatile arterial blood…

Signal Processing · Electrical Eng. & Systems 2024-10-22 Marco Giordano , Christoph Leitner , Christian Vogt , Luca Benini , Michele Magno