This paper describes the small-diameter monitored drift-tube detector construction at the University of Michigan as a contribution to the ATLAS Muon Spectrometer upgrade for the high-luminosity Large Hadron Collider at CERN. Measurements of…

Timing characteristics of two multigap RPCs were compared. One had four subgaps 0.3 mm wide and the other - two subgaps 0.6 mm wide. Specially developed electronics was used. Electronics resolution convoluted with measured charge spectra at…

High Energy Physics - Experiment · Physics 2007-05-23 V. Ammosov , V. Gapienko , A. Ivanilov , A. Semak , Yu. Sviridov , E. Usenko , V. Zaets

Large-scale systems, such as very large accelerators used for fundamental research, require the implementation of precise timing and synchronization systems over distances of several tens of kilometers. A very high precision has been…

Accelerator Physics · Physics 2026-02-25 Alice Renaux , Ronic Chiche , A. Martens , Antoine Back , Paul-Éric Pottie , Daniel Charlet

We present the design, bench-top setup, and experimental results of a compact heterodyne interferometer that achieves picometer-level displacement sensitivities in air over frequencies above 100 mHz. The optical configuration with spatially…

Instrumentation and Detectors · Physics 2020-07-15 Ki-Nam Joo , Erin Clark , Yanqi Zhang , Jonathan D. Ellis , Felipe Guzman

Photosensitive gaseous detectors with a simple photoelectron multiplication mechanism of resistive plate chambers (RPCs) are expected to have both a large photocoverage and an excellent time resolution and to be low-cost. To demonstrate the…

Instrumentation and Detectors · Physics 2023-05-24 K. Matsuoka , R. Okubo , Y. Adachi

A challenging goal of 20 ps for the total time resolution of the Multi-gap Resistive Plate Chambers (MRPCs) system has been recently addressed by high energy physics experiments. In order to meet this requirement, one should have a deeper…

Instrumentation and Detectors · Physics 2019-10-15 Fuyue Wang , Dong Han , Yi Wang , Pengfei Lyu , Yuanjing Li

The SAMpler for PICosecond time (SAMPIC) chip has been designed by a collaboration including CEA/IRFU/SEDI, Saclay and CNRS/LAL/SERDI, Orsay. It benefits from both the quick response of a time to digital converter and the versatility of a…

We report the design, construction, and initial commissioning results of a large high pressure gaseous Time Projection Chamber (TPC) with Micromegas modules for charge readout. The detector vessel has an inner volume of about 600 L and an…

The Multigap Resistive Plate Chambers (MRPCs) provide excellent timing as well as position resolutions at relatively low cost. Therefore, they can be used in medical imaging applications such as PET where precise timing is a crucial…

Instrumentation and Detectors · Physics 2019-07-23 M. Nizam , B. Satyanarayana , R. R. Shinde , G. Majumder

Test beam measurements have been carried out with a 3D sensor on a Timepix3 ASIC and the time measurements are presented. The measurements are compared to those of a thin planar sensor on Timepix3. It is shown that for a perpendicularly…

The analog front-end electronics based on the constant fraction discrimination method is designed and optimized for the Multigap Resistive Plate Chamber (MRPC) timing measurements. The total time resolution of 40 ps has been obtained for 10…

Instrumentation and Detectors · Physics 2025-05-29 L. L. Kurchaninov , E. A. Ladygin , V. P. Ladygin , A. A. Semak

We consider a mesoscopic measuring device whose conductance is sensitive to the state of a two-level system. The detector is described with the help of its scattering matrix. Its elements can be used to calculate the relaxation and…

Mesoscale and Nanoscale Physics · Physics 2009-11-07 S. Pilgram , M. Buttiker

The upgrades of ATLAS and CMS for the High Luminosity LHC (HL-LHC) highlighted physics objects timing as a tool to resolve primary interactions within a bunch crossing. Since the expected pile-up is around 200, with an r.m.s. time spread of…

Beam studies of thin single- and double-stage THGEM-based detectors are presented. Several 10 x 10 cm^2 configurations with a total thickness of 5-6 mm (excluding readout electronics), with 1 x 1 cm^2 pads inductively coupled through a…

We present a microchannel plate (MCP) detector for compact time-of-flight mass spectrometers (TOF-MS) that jointly optimizes the anode geometry and high-voltage AC-decoupling network for electrically floating operation. Undershoot-driven…

Instrumentation and Detectors · Physics 2026-05-29 Robin F. Bonny , Lorenzo Obersnel , Martin Rubin , André Galli , Peter Wurz , Rico G. Fausch

Ultra-Fast Silicon Detectors (UFSDs) are n-in-p silicon detectors that implement moderate gain (typically 5 to 25) using a thin highly doped p++ layer between the high resistivity p-bulk and the junction of the sensor. The presence of gain…

The Multi-Purpose Detector (MPD) is to be installed at the Nuclotron Ion Collider fAcility (NICA) of the Joint Institute for Nuclear Research (JINR). Its main goal is to study the phase diagram of the strongly interacting matter produced in…

The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a…

We present the performance of multiplexed XY resistive Micromegas detectors tested in the CERN SPS 100 GeV/c electron beam at intensities up to 3.3 $\times$ 10$^5$ e$^- $/(s$\cdot$cm$^2$). So far, all studies with multiplexed Micromegas…