English
Related papers

Related papers: FastCAT: Fast Cone Beam CT (CBCT) Simulation

200 papers

Purpose: To experimentally validate the Fastcat cone beam CT (CBCT) simulator against kV and MV CBCT images acquired with a Varian Truebeam linac. Methods: kV and MV CBCT images of a Catphan 504 phantom were acquired using a 100 kVp beam…

Medical Physics · Physics 2022-01-19 Jericho O'Connell , Clayton Lindsay , Magdalena Bazalova-Carter

Cone-beam CT (CBCT) has been widely used in image guided radiation therapy (IGRT) to acquire updated volumetric anatomical information before treatment fractions for accurate patient alignment purpose. However, the excessive x-ray imaging…

Medical Physics · Physics 2010-04-13 Xun Jia , Yifei Lou , John Lewis , Ruijiang Li , Xuejun Gu , Chunhua Men , William Y. Song , Steve B. Jiang

Recently, X-ray imaging dose from computed tomography (CT) or cone beam CT (CBCT) scans has become a serious concern. Patient-specific imaging dose calculation has been proposed for the purpose of dose management. While Monte Carlo (MC)…

Medical Physics · Physics 2015-05-30 Xun Jia , Hao Yan , Xuejun Gu , Steve B. Jiang

In computed tomography (CT) reconstruction, scattering causes server quality degradation of the reconstructed CT images by introducing streaks and cupping artifacts which reduce the detectability of low contrast objects. Monte Carlo (MC)…

Image and Video Processing · Electrical Eng. & Systems 2022-02-01 Ammar Alsaffar , Steffen Kieß , Kaicong Sun , Sven Simon

Purpose: Scatter artifacts drastically degrade the image quality of cone-beam computed tomography (CBCT) scans. Although deep learning-based methods show promise in estimating scatter from CBCT measurements, their deployment in mobile CBCT…

Signal Processing · Electrical Eng. & Systems 2025-09-12 Harshit Agrawal , Ari Hietanen , Simo Särkkä

Simulation of x-ray projection images plays an important role in cone beam CT (CBCT) related research projects. A projection image contains primary signal, scatter signal, and noise. It is computationally demanding to perform accurate and…

Medical Physics · Physics 2015-06-04 Xun Jia , Hao Yan , Laura Cervino , Michael Folkerts , Steve B. Jiang

Purpose: Cone-beam CT (CBCT) plays an important role in image guided radiation therapy (IGRT). However, the large radiation dose from serial CBCT scans in most IGRT procedures raises a clinical concern, especially for pediatric patients who…

Medical Physics · Physics 2015-05-18 Xun Jia , Yifei Lou , Ruijiang Li , William Y. Song , Steve B. Jiang

The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain…

Medical Physics · Physics 2016-04-27 Wei Zhao , Don Vernekohl , Jun Zhu , Luyao Wang , Lei Xing

Scattered coincidences introduce quantitative bias in positron emission tomography (PET) and must be compensated during reconstruction. Conventional scatter estimates typically rely on simplified cylindrical scanner models that omit…

X-ray imaging dose from serial cone-beam CT (CBCT) scans raises a clinical concern in most image guided radiation therapy procedures. It is the goal of this paper to develop a fast GPU-based algorithm to reconstruct high quality CBCT images…

Medical Physics · Physics 2015-05-19 Xun Jia , Bin Dong , Yifei Lou , Steve B. Jiang

Cone-beam computed tomography (CBCT) offers advantages over conventional fan-beam CT in that it requires a shorter time and less exposure to obtain images. CBCT has found a wide variety of applications in patient positioning for…

Computer Vision and Pattern Recognition · Computer Science 2020-07-01 S. Kida , S. Kaji , K. Nawa , T. Imae , T. Nakamoto , S. Ozaki , T. Ohta , Y. Nozawa , K. Nakagawa

Cone beam CT (CBCT) has been widely used for patient setup in image guided radiation therapy (IGRT). Radiation dose from CBCT scans has become a clinical concern. The purposes of this study are 1) to commission a GPU-based Monte Carlo (MC)…

The concept of using kilovoltage (kV) and megavoltage (MV) beams concurrently has potential applications in cone beam computed tomography (CBCT) guided radiation therapy, such as single breath hold scans, metal artifact reduction, and…

Medical Physics · Physics 2022-08-24 Farhang Bayat , Mohamed Elsayed Eldib , Brian Kavanagh , Moyed Miften , Cem Altunbas

Cone beam computed tomography (CBCT) for breast imaging has potential to replace conventional mammograms. However, concerns over dose and image quality prevent CBBCT systems from the clinical trial phase to next stage. The time of flight…

Medical Physics · Physics 2021-02-01 Ignacio O. Romero , Changqing Li

Cone-beam CT (CBCT) is installed in the treatment room to facilitate online clinical applications, including image guidance in radiation and surgery. Half-fan and short-can are the commonly used modes in clinical applications to expand the…

Medical Physics · Physics 2022-05-24 Junbo Peng

Purpose: Fast kV-switching (FKS) and dual-layer flat-panel detector (DL-FPD) technologies have been actively studied as promising dual-energy solutions for FPD-based cone-beam computed tomography (CBCT). However, CBCT spectral imaging is…

Medical Physics · Physics 2024-01-03 Hao Zhou , Li Zhang , Zhilei Wang , Hewei Gao

Cone-beam computed tomography (CBCT) is routinely collected during image-guided radiation therapy (IGRT) to provide updated patient anatomy information for cancer treatments. However, CBCT images often suffer from streaking artifacts and…

Computer Vision and Pattern Recognition · Computer Science 2023-11-02 Jiarui Zhu , Werxing Chen , Hongfei Sun , Shaohua Zhi , Jing Qin , Jing Cai , Ge Ren

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy (IGRT). It provides real time visualization at low cost and dose. However, photon scattering and beam hindrance cause artifacts in CBCT. These include…

Medical Physics · Physics 2025-09-29 Alzahra Altalib , Chunhui Li , Alessandro Perelli

We provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. The method starts with an estimation of coarse scatter profile for a set of CBCT images. A total-variation denoising algorithm designed…

Medical Physics · Physics 2015-01-20 Wei Zhao , Jun Zhu , Luyao Wang

MiniCACTUS is a monolithic sensor prototype optimised for timing measurement of charged particles. It has been designed in a standard 150 nm CMOS process without dedicated amplification layer. It is intended as a demonstrator chip for…

Instrumentation and Detectors · Physics 2023-09-18 Yavuz Degerli , Fabrice Guilloux , Tomasz Hemperek , Jean-Pierre Meyer , Philippe Schwemling
‹ Prev 1 2 3 10 Next ›