Related papers: Comparative scintillation performance of EJ-309, E…
In this manuscript we report on the scintillation properties and pulse shape discrimination (PSD) performance of new organic glass scintillator. Two cylindrical samples with dimensions of 2x2 inches were tested. Additionally, this two…
Background: Organic scintillators are widely used for neutron detection in both basic nuclear physics and applications. While the proton light yield of organic scintillators has been extensively studied, measurements of the light yield from…
Scintillators with pulse-shape discrimination (PSD) capability are of great interest to many fields in the scientific community. The ability to discern a gamma ray from a neutron using PSD varies between different types of scintillator…
Recent progress in the development of novel organic scintillators necessitates modern characterization capabilities. As the primary means of energy deposition by neutrons in these materials is n-p elastic scattering, knowledge of the proton…
A comparative study of the neutron-$\gamma$ Pulse Shape Discrimination (PSD) with seven organic scintillators is performed using an identical setup and digital electronics. The scintillators include plastics (EJ-299-33 and a plastic…
Detailed characterization of the newly available plastic scintillator (EJ-299-33A) having the pulse shape discrimination (PSD) property has been carried out in case of a large-sized detector (5 in.$\times$5 in.). The pulse height response…
Plastic organic scintillators have been tailored in composition to achieve ultra-fast temporal response, thereby enabling the design and development of fast neutron detection systems with high timing resolution. Eljen Technology's plastic…
In this paper, we present an investigation into the scintillation properties and pulse shape discrimination (PSD) performance of the new BSO-406, which is a blend of 40% organic glass scintillator and 60% polystyrene. We tested a…
Organic scintillators doped with capture agents provide a detectable signal for neutrons over a broad energy range. This work characterizes the fast and slow neutron response of EJ-254, an organic plastic scintillator with 5% natural boron…
Compact neutron imagers using double-scatter kinematic reconstruction are being designed for localization and characterization of special nuclear material. These neutron imaging systems rely on scintillators with a rapid prompt temporal…
We present a detailed characterization of the thermal neutron sensitive transparent glass scintillator SG101, benchmarked against the conventional LiF ZnS(Ag)based scintillator EJ426. The detection efficiency, energy resolution, and pulse…
Organic scintillators using a solid polyurethane (PU) matrix have been introduced to combine the robustness of a construction material with scintillating properties that allow gamma rays and fast neutrons to be detected efficiently and at…
In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was…
The absolute light yield of a scintillator, defined as the number of scintillation photons produced per unit energy deposited, is a useful quantity for scintillator development, research, and applications. Yet, literature data on the…
Organic scintillators exhibit fast timing, high detection efficiency for fast neutrons and pulse shape discrimination (PSD) capability. PSD is essential in mixed radiation fields, where different types of radiation need to be detected and…
A $^6$Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ-299-50, has been developed and produced at the kilogram-scale. A total of 44 kg-scale bars of dimensions 5.5 cm $\times$ 5.5 cm…
The proton light yield of organic scintillators has been measured extensively in recent years using fast waveform digitizers and large discrepancies exist in the values reported by different authors. In this letter, we address principles of…
Organic glass scintillators are an interesting alternative to liquid scintillators, offering many advantageous characteristics with few drawbacks. In this paper we investigate the influence of light self-absorption in the organic glass…
A meter-long, 23-liter EJ-309 liquid scintillator detector has been constructed to study the light collection and pulse-shape discrimination performance of elongated scintillator cells for the PROSPECT reactor antineutrino experiment. The…
A new type of neutron detector, named Stack Structure Solid organic Scintillator (S$^4$), consisting of multi-layer plastic scintillators with capability to suppress low-energy $\gamma$ rays under high-counting rate has been constructed and…