English
Related papers

Related papers: Inferring respiratory and circulatory parameters f…

200 papers

Objective: Time-difference electrical impedance tomography (EIT) is gaining widespread use for bedside lung monitoring in intensive care patients suffering from lung-related diseases. It involves collecting voltage measurements from…

Electrical impedance tomography (EIT) is a non-invasive imaging technique, capable of reconstructing images of the electrical conductivity of tissues and materials. It is popular in diverse application areas, from medical imaging to…

Computer Vision and Pattern Recognition · Computer Science 2024-12-24 Shuaikai Shi , Ruiyuan Kang , Panos Liatsis

The objective of electrical impedance tomography (EIT) is to reconstruct the internal conductivity of a physical body based on current and voltage measurements at the boundary of the body. In many medical applications the exact shape of the…

Optimization and Control · Mathematics 2021-10-25 J. P. Agnelli , V. Kolehmainen , M. Lassas , P. Ola , S. Siltanen

The Pulmonary Function Test (PFT) is an widely utilized and rigorous classification test for lung function evaluation, serving as a comprehensive tool for lung diagnosis. Meanwhile, Electrical Impedance Tomography (EIT) is a rapidly…

Image and Video Processing · Electrical Eng. & Systems 2023-07-04 Shuzhe Chen , Li Li , Zhichao Lin , Ke Zhang , Ying Gong , Lu Wang , Xu Wu , Maokun Li , Yuanlin Song , Fan Yang , Shenheng Xu

Patients suffering from pulmonary diseases typically exhibit pathological lung ventilation in terms of homogeneity. Electrical Impedance Tomography (EIT) is a non-invasive imaging method that allows to analyze and quantify the distribution…

A wireless wearable Electrical Impedance Tomography (EIT) system has been developed utilizing the AD5933 chip to achieve real-time imaging of lung respiration. The system employs a voltage excitation method tailored to human impedance…

Medical Physics · Physics 2026-03-09 Bowen Li , Zekun Chen , Xuefei Chen , Luhao Zhang , Shili Liang

Electrical impedance tomography (EIT) is a non-invasive functional imaging technology. In order to enhance the quality of lung EIT images, novel algorithms, namely LSTM-LSTM, LSTM-BiLSTM, BiLSTM-LSTM, and BiLSTM-BiLSTM, leveraging LSTM or…

Biological Physics · Physics 2025-04-22 Zhenzhong Song , Jianping Li , Jun Zhang , Hanyun Wen , Suqin Zhang , Wei Jiang , Xingxing Zhou

Electrical Impedance Tomography (EIT) is a powerful imaging technique with diverse applications, e.g., medical diagnosis, industrial monitoring, and environmental studies. The EIT inverse problem is about inferring the internal conductivity…

Machine Learning · Computer Science 2023-10-31 Derick Nganyu Tanyu , Jianfeng Ning , Andreas Hauptmann , Bangti Jin , Peter Maass

Electrical impedance tomography (EIT) is a noninvasive imaging method whereby electrical measurements on the boundary of a conductive medium (the data) are taken according to a prescribed protocol set and inverted to map the internal…

Electrical impedance tomography (EIT) is a non-invasive imaging method in which an unknown physical body is probed with electric currents applied on the boundary, and the internal conductivity distribution is recovered from the measured…

Numerical Analysis · Mathematics 2014-02-07 Sarah Jane Hamilton , Samuli Siltanen

This paper presents a monotonicity-based spatiotemporal conductivity imaging method for continuous regional lung monitoring using electrical impedance tomography (EIT). The EIT data (i.e., the boundary current-voltage data) can be…

Quantitative Methods · Quantitative Biology 2018-02-16 Liangdong Zhou , Bastian Harrach , Jin Keun Seo

Electrical Impedance Tomography (EIT) aims to recover the internal conductivity and permittivity distributions of a body from electrical measurements taken on electrodes on the surface of the body. The reconstruction task is a severely…

Numerical Analysis · Mathematics 2016-05-25 Sarah Jane Hamilton , Jennifer L. Mueller , Melody Alsaker

Electrical impedance tomography (EIT) is an imaging method that is able to estimate the electrical conductivity distribution of living tissue. This work presents a field programmable gate array (FPGA)-based multi-frequency EIT system for…

Electrical Impedance Tomography (EIT) is a powerful imaging modality widely used in medical diagnostics, industrial monitoring, and environmental studies. The EIT inverse problem is about inferring the internal conductivity distribution of…

Image and Video Processing · Electrical Eng. & Systems 2025-08-11 Alexander Denker , Fabio Margotti , Jianfeng Ning , Kim Knudsen , Derick Nganyu Tanyu , Bangti Jin , Andreas Hauptmann , Peter Maass

Electrical impedance tomography (EIT) is a non-invasive imaging technique, which has been widely used in the fields of industrial inspection, medical monitoring and tactile sensing. However, due to the inherent non-linearity and…

Computer Vision and Pattern Recognition · Computer Science 2025-01-13 Duanpeng Shi , Wendong Zheng , Di Guo , Huaping Liu

Electrical Impedance Tomography (EIT) is a functional imaging method that is being developed for bedside use in critical care medicine. Aiming at improving the chest anatomical resolution of EIT images we developed a fuzzy model based on…

In this paper, we present a discussion on the algorithms design of Electrical Impedance Tomography (EIT) for biomedical applications. Based on the Maxwell differential equations and the derived the finite element(FE) linear equations, we…

Signal Processing · Electrical Eng. & Systems 2019-01-23 Mingyong Zhou , Hongyu Zhu

Objective: A model is presented to evaluate the viability of using electrical impedance tomography (EIT) with a nerve cuff to record neural activity in peripheral nerves. Approach: Established modelling approaches in neural-EIT are expanded…

Neurons and Cognition · Quantitative Biology 2018-05-09 J. Hope , F. Vanholsbeeck , A. McDaid

This paper presents a mathematical framework for a flexible pressure-sensor model using electrical impedance tomography (EIT). When pressure is applied to a conductive membrane patch with clamped boundary, the pressure-induced surface…

Analysis of PDEs · Mathematics 2014-09-15 Habib Ammari , Kyungkeun Kang , Kyounghun Lee , Jin Keun Seo

Owing to recent advances in thoracic electrical impedance tomography, a patient's hemodynamic function can be noninvasively and continuously estimated in real-time by surveilling a cardiac volume signal associated with stroke volume and…

Signal Processing · Electrical Eng. & Systems 2023-01-05 Chang Min Hyun , Tae Jun Jang , Jeongchan Nam , Hyeuknam Kwon , Kiwan Jeon , Kyunghun Lee
‹ Prev 1 2 3 10 Next ›