Related papers: Modified Kernel MLAA Using Autoencoder for PET-ena…
We propose a novel Learned Alternating Minimization Algorithm (LAMA) for dual-domain sparse-view CT image reconstruction. LAMA is naturally induced by a variational model for CT reconstruction with learnable nonsmooth nonconvex…
In this paper, we first propose a variational model for the limited-angle computed tomography (CT) image reconstruction and then convert the model into an end-to-end deep network.We use the penalty method to solve the model and divide it…
Helical CT has been widely used in clinical diagnosis. Sparsely spaced multidetector in z direction can increase the coverage of the detector provided limited detector rows. It can speed up volumetric CT scan, lower the radiation dose and…
Dual-energy CT (DECT) has been widely investigated to generate more informative and more accurate images in the past decades. For example, Dual-Energy Alternating Minimization (DEAM) algorithm achieves sub-percentage uncertainty in…
Image-generative artificial intelligence (AI) has garnered significant attention in recent years. In particular, the diffusion model, a core component of generative AI, produces high-quality images with rich diversity. In this study, we…
Computed tomography (CT) is widely used in screening, diagnosis, and image-guided therapy for both clinical and research purposes. Since CT involves ionizing radiation, an overarching thrust of related technical research is development of…
Current methods for magnetic resonance-based positron emission tomography attenuation correction (PET-MR AC) are time consuming, and less able than computed tomography (CT)-based AC methods to capture inter-individual variability and skull…
This paper applies the recent fast iterative neural network framework, Momentum-Net, using appropriate models to low-dose X-ray computed tomography (LDCT) image reconstruction. At each layer of the proposed Momentum-Net, the model-based…
Low-dose computed tomography (LDCT) offers reduced X-ray radiation exposure but at the cost of compromised image quality, characterized by increased noise and artifacts. Recently, transformer models emerged as a promising avenue to enhance…
Computed tomography (CT) can provide a 3D view of the patient's internal organs, facilitating disease diagnosis, but it incurs more radiation dose to a patient and a CT scanner is much more cost prohibitive than an X-ray machine too.…
The accurate segmentation of lesions in whole-body PET/CT imaging is es-sential for tumor characterization, treatment planning, and response assess-ment, yet current manual workflows are labor-intensive and prone to inter-observer…
Convolutional neural networks (CNNs) have recently achieved remarkable performance in positron emission tomography (PET) image reconstruction. In particular, CNN-based direct PET image reconstruction, which directly generates the…
Patient motion during PET is inevitable. Its long acquisition time not only increases the motion and the associated artifacts but also the patient's discomfort, thus PET acceleration is desirable. However, accelerating PET acquisition will…
Low-dose computed tomography (LDCT) aims to minimize the radiation exposure to patients while maintaining diagnostic image quality. However, traditional CT reconstruction algorithms often struggle with the ill-posed nature of the problem,…
Although supervised convolutional neural networks (CNNs) often outperform conventional alternatives for denoising positron emission tomography (PET) images, they require many low- and high-quality reference PET image pairs. Herein, we…
Dual spectral computed tomography (DSCT) can achieve energy- and material-selective images, and has a superior distinguishability of some materials than conventional single spectral computed tomography (SSCT). However, the decomposition…
We propose in this work a framework for synergistic positron emission tomography (PET)/computed tomography (CT) reconstruction using a joint generative model as a penalty. We use a synergistic penalty function that promotes PET/CT pairs…
Deep learning based computed tomography (CT) reconstruction has demonstrated outstanding performance on simulated 2D low-dose CT data. This applies in particular to domain adapted neural networks, which incorporate a handcrafted physics…
Photon counting spectral CT (PCCT) can produce reconstructed attenuation maps in different energy channels, reflecting energy properties of the scanned object. Due to the limited photon numbers and the non-ideal detector response of each…
Deep neural networks have a great potential to improve image denoising in low-dose computed tomography (LDCT). Popular ways to increase the network capacity include adding more layers or repeating a modularized clone model in a sequence. In…