Related papers: Improved limits for violations of local position i…
We propose a new frequency standard based on a $4f^{14} 6s6p~ ^3\!P_0 - 4f^{13} 6s^2 5d ~(J=2)$ transition in neutral Yb. This transition has a potential for high stability and accuracy and the advantage of the highest sensitivity among…
We report direct measurements of the frequency ratio of the 642 THz ${}^2S_{1/2} (F=0)$--${}^2F_{7/2} (F=3)$ electric octupole transition in ${}^{171}\mathrm{Yb}^+$ and the 429 THz ${}^1S_0$--${}^3P_0$ transition in ${}^{87}\mathrm{Sr}$. A…
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with an accuracy of ~10^{-15}. These measurements set a stringent…
Demands from several areas of science and technology have lead to a worldwide search for accurate optical clocks with an uncertainty of 1 part in $10^{18}$, which is $10^{3}$ times more accurate than the present day cesium atomic clocks…
We compare the sensitivity of a recent bound on time variation of the fine structure constant from optical clocks with bounds on time varying fundamental constants from atomic clocks sensitive to the electron-to-proton mass ratio, from…
We report high-precision frequency ratio measurements between optical atomic clocks based on $^{27}$Al$^+$, $^{171}$Yb, and $^{87}$Sr. With total fractional uncertainties at or below $3.2 \times 10^{-18}$, these measurements meet an…
Dependence of transition frequencies on the fine structure constant $\alpha=e^2/\hbar c$ is calculated for several many-electron systems which are used or planned to be used in the laboratory search for the time variation of the fine…
We have remeasured the absolute $1S$-$2S$ transition frequency $\nu_{\rm {H}}$ in atomic hydrogen. A comparison with the result of the previous measurement performed in 1999 sets a limit of $(-29\pm 57)$ Hz for the drift of $\nu_{\rm {H}}$…
We report a joint test of local Lorentz invariance and the Einstein equivalence principle for electrons, using long-term measurements of the transition frequency between two nearly degenerate states of atomic dysprosium. We present…
A full evaluation of the uncertainty budget for the ytterbium ion optical clock at the National Physical Laboratory (NPL) was performed on the electric octupole (E3) $^2\mathrm{S}_{1/2}\,\rightarrow\, ^2\mathrm{F}_{7/2}$ transition. The…
We report on the spectroscopy of radio-frequency transitions between nearly-degenerate, opposite-parity excited states in atomic dysprosium (Dy). Theoretical calculations predict that these states are very sensitive to variation of the…
We report on new tests that improve our previous (2009-2010) estimates of the electron-to-proton mass ratio variation, mu = m_e/m_p. Subsequent observations (2011-2013) at the Effelsberg 100-m telescope of a sample of eight molecular cores…
We study ultranarrow $5s_{1/2}$ - $4f_{5/2}$ transitions in Nd$^{13+}$ and Sm$^{15+}$ and demonstrate that they lie in the optical region. The transitions are insensitive to external perturbations. At the same time they are sensitive to the…
Atomic microwave clocks based on hyperfine transitions, such as the caesium standard, tick with a frequency that is proportional to the magnetic moment of the nucleus. This magnetic moment varies strongly between isotopes of the same atom,…
Divalent atoms and ions with a singlet $S$ ground state and triplet $P$ excited state form the basis of many high-precision optical atomic clocks. Along with the metastable $^{3}\mathrm{P}_{0}$ clock state, these atomic systems also have a…
We report a limit on the fractional temporal variation of the proton-to-electron mass ratio as, obtained by comparing the frequency of a rovibrational transition in SF6 with the fundamental hyperfine transition in Cs. The SF6 transition was…
A possibility for fundamental constants to vary in time is suggested by theories unifying gravity with other interactions. In this article we examine proposals to use optical transitions of Sr, Dy, YbII and YbIII for the search of the time…
State-resolved laser spectroscopy at the 10$^{-12}$ precision level recently reported in $arXiv$:2406.18719 determined the fractional change in nuclear quadrupole moment between the ground and isomeric state of $^{229}\rm{Th}$, $\Delta…
We analyse the constraints obtained from new atomic clock data on the possible time variation of the fine structure `constant' and the electron-proton mass ratio and show how they are strengthened when the seasonal variation of Sun's…
Optical frequency comparison of the 40Ca+ clock transition \nu_{Ca} (2S1/2-2D5/2, 729nm) against the 87Sr optical lattice clock transition \nu_{Sr}(1S0-3P0, 698nm) has resulted in a frequency ratio \nu_{Ca} / \nu_{Sr} = 0.957 631 202 358…