Related papers: Cryogenic suspension design for a kilometer-scale …
This paper demonstrates a cryogenic deformable mirror (DM) with 1,020 actuators based on micro-electrical mechanical systems (MEMS) technology. Cryogenic space-borne infrared telescopes can experience a wavefront error due to a figure error…
We present the calculation of thermal noise in interferometric gravitational-wave detectors due to the thermal fluctuations of the beam splitter (BS). This work makes use of a recently developed method of the analysis of thermal noise in…
We report on the design of a cryogenic setup for trapped ion quantum computing containing a segmented surface electrode trap. The heat shield of our cryostat is designed to attenuate alternating magnetic field noise, resulting in 120~dB…
We present the design and implementation of a mechanical low-pass filter vibration isolation used to reduce the vibrational noise in a cryogen-free dilution refrigerator operated at 10 mK, intended for scanning probe techniques. We discuss…
Suitable shaping (in particular, flattening and broadening) of the laser beam has recently been proposed as an effective device to reduce internal (mirror) thermal noise in advanced gravitational wave interferometric detectors. Based on…
Thermal lensing in resonant optical interferometers such as those used for gravitational wave detection is a concern due to the negative impact on control signals and instrument sensitivity. In this paper we describe a method for monitoring…
KAGRA, the kilometer-scale underground gravitational-wave detector, is located at Kamioka, Japan. In April 2020, an astrophysics observation was performed at the KAGRA detector in combination with the GEO 600 detector; this observation…
The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory…
In order to achieve full detection sensitivity at low frequencies, the mirrors of interferometric gravitational wave detectors must be isolated from seismic noise. The VIRGO vibration isolator, called 'superattenuator', is fully effective…
The operation of an interferometer for gravitational waves detection requires sophisticated feedback controls in many parts of the apparatus. The aim of this lecture is to introduce the types of problems to be faced in this line of…
The detection of gravitational-waves provides us with a deep insight into the universe. In order to increase the number of detectable gravitational-wave sources, several future gravitational-wave detectors will operate with cryogenic…
We studied noise properties of microwave signals transmitted through the cryogenic resonator. The experiments were performed with the 11.342 GHz sapphire loaded cavity resonator cooled to 6.2 K. Based on the measured transmission…
Extraneous thermal motion can limit displacement sensitivity and radiation pressure effects, such as optical cooling, in a cavity-optomechanical system. Here we present an active noise suppression scheme and its experimental implementation.…
We develop a steady-state analytical and numerical model of the optical response of power-recycled Fabry-Perot Michelson laser gravitational-wave detectors to thermal focusing in optical substrates. We assume that the thermal distortions…
The use of fused-silica ribbons as suspensions in gravitational wave interferometers can result in significant improvements in pendulum mode thermal noise. Surface loss sets a lower bound to the level of noise achievable, at what level…
We consider the radiative trapping and cooling of a partially transmitting mirror suspended inside an optical cavity, generalizing the case of a perfectly reflecting mirror previously considered [M. Bhattacharya and P. Meystre, Phys. Rev.…
Coating thermal noise in high-reflectivity test-mass mirrors is a major limitation for future gravitational-wave detectors, especially in the 10--300 Hz band. ET-Pathfinder therefore requires mirror coatings that combine very high…
Thermoelastic loss is an important energy dissipation mechanisms in resonant systems. A careful analysis of the thermoelastic loss is critical to the design of low-noise devices for high-precision applications, such as the mirrors used for…
Environmental noise is one of the critical issues for the observation of gravitational waves, but is difficult to predict in advance. Therefore, to evaluate the adverse impact of environmental noise on the detector sensitivity,…
We present a novel system to calibrate millimeter-wave polarimeters for CMB polarization measurements. This technique is an extension of the conventional metal mirror rotation approach, however it employs cryogenically-cooled blackbody…