English
Related papers

Related papers: Absolute X-ray energy measurement using a high-acc…

200 papers

The photon spectrum in the inclusive electromagnetic radiative decays of the $B$ meson, $B \to X_{s} \gamma$ plus $B \to X_{d} \gamma$, is studied using a data sample of $(382.8 \pm 4.2) \times 10^6$ $\Upsilon(4S) \to B\overli\ ne{B}$…

High Energy Physics - Experiment · Physics 2013-05-30 The BaBar Collaboration

Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20 keV energy range. We are building a TES-based instrument for the…

Instrumentation and Detectors · Physics 2020-08-26 Tejas Guruswamy , Lisa M. Gades , Antonino Miceli , Umeshkumar M. Patel , John T. Weizeorick , Orlando Quaranta

We report a fully inclusive measurement of the flavour changing neutral current decay b->s gamma in the energy range 1.8 GeV < E* < 2.8 GeV, covering 95% of the total spectrum. Using 140 fb^-1 we obtain BF(b->s gamma)= 3.55 +/- 0.32…

High Energy Physics - Experiment · Physics 2019-08-14 P. Koppenburg

Detecting the X-ray radialization of pulsars and obtaining the photons' time of arrival are the foundation steps in autonomous navigation via X-ray pulsar measurement. The precision of a pulse' s time of arrival is mainly decided by the…

Instrumentation and Detectors · Physics 2015-06-16 Li Liu , Wei Zheng

A flexible apparatus for calibration of the absolute flux at the focal plane of the X-ray Source of a Powder Diffractometer, based on a fast scintillator counter, is presented. The measured fluxes, depending on the high voltage on the X-ray…

Instrumentation and Detectors · Physics 2020-08-27 Emmanuel Fokitis , Theodoros Geralis , Stavros Maltezos , Nikolaos Vodinas

We propose a new method to measure the absolute photon absorption cross section of neutral molecules in a molecular beam. It is independent of our knowledge of the particle beam density, nor does it rely on photo-induced fragmentation or…

Quantum Physics · Physics 2008-12-31 Stefan Nimmrichter , Klaus Hornberger , Hendrik Ulbricht , Markus Arndt

Superconducting resonators have to date been used for photon detection in a non-equilibrium manner. In this paper, we demonstrate that such devices can also be used in a thermal quasi-equilibrium manner to detect X-ray photons. We have used…

Superconductivity · Physics 2015-06-15 Orlando Quaranta , Thomas Cecil , Lisa Gades , Benjamin Mazin , Antonino Miceli

We propose a new scheme for measuring the quantum efficiency of photon counting detectors by using correlated pho-tons. The measurement technique is based on a 90 rotation of the polarization of one photon member of a correlated pair…

This paper presents the electron and photon energy calibration obtained with the ATLAS detector using about 36 fb$^{-1}$ of LHC proton-proton collision data recorded at $\sqrt{s}=13$ TeV in 2015 and 2016. The different calibration steps…

High Energy Physics - Experiment · Physics 2019-03-21 ATLAS Collaboration

A comparison of the inclusive photon energy spectrum in the radiative decay $\BGAMAXS$, measured recently by the CLEO collaboration, with the standard model is presented, using a $B$-meson wave function model and improving earlier…

High Energy Physics - Phenomenology · Physics 2011-01-05 A. Ali , C. Greub

Time-resolved photoconductivity is widely used to characterize non-equilibrium charge-carrier lifetime, impurity content, and solar cell efficiency in a broad range of semiconductors. Most measurements are limited to the detection of…

Materials Science · Physics 2026-02-04 A. Bojtor , D. Krisztian , G. Parada , F. Korsos , S. Kollarics , G. Csosz , B. G. Markus , L. Forro , F. Simon

The electro-magnetic calorimeter at the BaBar detector, part of the asymmetric B Factory at SLAC, measures photons in the energy range from 20 MeV to 8 GeV with good resolution. The calorimeter is calibrated at the low energy end with 6.13…

Instrumentation and Detectors · Physics 2019-08-14 Johannes M. Bauer

A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using a method of an alpha-gamma counter. The method involves only the counting of measured rates and is independent…

Instrumentation and Detectors · Physics 2018-07-04 A. T. Yue , E. S. Anderson , M. S. Dewey , D. M. Gilliam , G. L. Greene , A. B. Laptev , J. S. Nico , W. M. Snow

We show a setup for characterising the efficiency of a single-photon-detector absolutely and with a precision better of 1%. Since the setup does not rely on calibrated devices and can be implemented with standard-optic components, it can be…

Instrumentation and Detectors · Physics 2023-07-19 Tommaso Lunghi , Boris Korzh , Bruno Sanguinetti , Hugo Zbinden

We describe a feasible implementation of a novel X-ray detector for highly energetic x-ray photons with a large solid angle coverage, optimal for the detection of Compton x-ray scattered photons. The device consists of a 20~cm-thick…

Instrumentation and Detectors · Physics 2022-01-27 Ángela Saá Hernández , Diego González-Díaz , Pablo Villanueva , Carlos Azevedo , Marcos Seoane

Spectrograph is an optical device that is used to disperse photons of different energies $E$ into distinct directions and space locations, and to take a snapshot of the whole spectrum of photon energies with a spatially sensitive photon…

Optics · Physics 2015-06-03 Yuri Shvyd'ko

Interplay of the angle dependent X-ray reflectivity and absorption with the photoelectron attenuation length in the photoelectron emission process determine the optimal X-ray incidence angle which maximizes the photoelectron signal.…

Instrumentation and Detectors · Physics 2012-12-18 Vladimir N. Strocov

Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments is still a matter of research. A possible technique exploits the information…

A performance evaluation of superconducting transition-edge sensors (TESs) in the environment of a pion beam line at a particle accelerator is presented. Averaged across the 209 functioning sensors in the array, the achieved energy…

The possibility of using the effect of full energy absorption in a light scintillator when an electron beam passes through it to determine the energy characteristics of a low and medium energy beam (the absorbed energy method) is…

Instrumentation and Detectors · Physics 2020-04-03 V. I. Alekseev , V. A. Baskov , V. A. Dronov , A. I. L'vov , A. V. Koltsov , Yu. F. Krechetov , V. V. Polyansky