Related papers: Absolute X-ray energy measurement using a high-acc…
The photon spectrum in the inclusive electromagnetic radiative decays of the $B$ meson, $B \to X_{s} \gamma$ plus $B \to X_{d} \gamma$, is studied using a data sample of $(382.8 \pm 4.2) \times 10^6$ $\Upsilon(4S) \to B\overli\ ne{B}$…
Transition Edge Sensor (TES) spectrometers for hard X-ray beamline science will enable improved X-ray emission and absorption spectroscopy in the information-rich 2 to 20 keV energy range. We are building a TES-based instrument for the…
We report a fully inclusive measurement of the flavour changing neutral current decay b->s gamma in the energy range 1.8 GeV < E* < 2.8 GeV, covering 95% of the total spectrum. Using 140 fb^-1 we obtain BF(b->s gamma)= 3.55 +/- 0.32…
Detecting the X-ray radialization of pulsars and obtaining the photons' time of arrival are the foundation steps in autonomous navigation via X-ray pulsar measurement. The precision of a pulse' s time of arrival is mainly decided by the…
A flexible apparatus for calibration of the absolute flux at the focal plane of the X-ray Source of a Powder Diffractometer, based on a fast scintillator counter, is presented. The measured fluxes, depending on the high voltage on the X-ray…
We propose a new method to measure the absolute photon absorption cross section of neutral molecules in a molecular beam. It is independent of our knowledge of the particle beam density, nor does it rely on photo-induced fragmentation or…
Superconducting resonators have to date been used for photon detection in a non-equilibrium manner. In this paper, we demonstrate that such devices can also be used in a thermal quasi-equilibrium manner to detect X-ray photons. We have used…
We propose a new scheme for measuring the quantum efficiency of photon counting detectors by using correlated pho-tons. The measurement technique is based on a 90 rotation of the polarization of one photon member of a correlated pair…
This paper presents the electron and photon energy calibration obtained with the ATLAS detector using about 36 fb$^{-1}$ of LHC proton-proton collision data recorded at $\sqrt{s}=13$ TeV in 2015 and 2016. The different calibration steps…
A comparison of the inclusive photon energy spectrum in the radiative decay $\BGAMAXS$, measured recently by the CLEO collaboration, with the standard model is presented, using a $B$-meson wave function model and improving earlier…
Time-resolved photoconductivity is widely used to characterize non-equilibrium charge-carrier lifetime, impurity content, and solar cell efficiency in a broad range of semiconductors. Most measurements are limited to the detection of…
The electro-magnetic calorimeter at the BaBar detector, part of the asymmetric B Factory at SLAC, measures photons in the energy range from 20 MeV to 8 GeV with good resolution. The calorimeter is calibrated at the low energy end with 6.13…
A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using a method of an alpha-gamma counter. The method involves only the counting of measured rates and is independent…
We show a setup for characterising the efficiency of a single-photon-detector absolutely and with a precision better of 1%. Since the setup does not rely on calibrated devices and can be implemented with standard-optic components, it can be…
We describe a feasible implementation of a novel X-ray detector for highly energetic x-ray photons with a large solid angle coverage, optimal for the detection of Compton x-ray scattered photons. The device consists of a 20~cm-thick…
Spectrograph is an optical device that is used to disperse photons of different energies $E$ into distinct directions and space locations, and to take a snapshot of the whole spectrum of photon energies with a spatially sensitive photon…
Interplay of the angle dependent X-ray reflectivity and absorption with the photoelectron attenuation length in the photoelectron emission process determine the optimal X-ray incidence angle which maximizes the photoelectron signal.…
Proton and carbon ion therapy is an emerging technique used for the treatment of solid cancers. The monitoring of the dose delivered during such treatments is still a matter of research. A possible technique exploits the information…
A performance evaluation of superconducting transition-edge sensors (TESs) in the environment of a pion beam line at a particle accelerator is presented. Averaged across the 209 functioning sensors in the array, the achieved energy…
The possibility of using the effect of full energy absorption in a light scintillator when an electron beam passes through it to determine the energy characteristics of a low and medium energy beam (the absorbed energy method) is…