Related papers: Zero-inertia Offshore Grids: N-1 Security and Acti…
Power systems dominated by converter-interfaced distributed energy resources (DERs) typically exhibit weaker damping capabilities and lower inertia, compromising system stability. Although individual DER controllers are evolving to provide…
Due to the rise of distributed energy resources, the control of networks of grid-forming inverters is now a pressing issue for power system operation. Droop control is a popular control strategy in the literature for frequency control of…
The unsteady power generation of a wind turbine translating in the streamwise direction is relevant to floating offshore wind turbines, kite-mounted airborne wind turbines, and other non-traditional wind-energy systems. To study this…
One of the most important challenges facing an electric grid is to incorporate renewables and distributed energy resources (DERs) to the grid. Because of the associated uncertainties in power generations and peak power demands,…
With the increasing penetration of converter-interfaced distributed generation systems, it would be advantageous to specify local compliance criteria for these devices to ensure the small-signal stability of the interconnected system.…
As renewable resources gradually replace conventional generation based synchronous machines, the dynamics of the modern grid changes significantly and the system synchronous inertia decreases substantially. This transformation poses severe…
Load-generation balance and system inertia are essential for maintaining frequency in power systems. Power grids are equipped with Rate-of-Change-of Frequency (ROCOF) and Load Shedding (LS) relays in order to keep load-generation balance.…
Offshore wind power is a renewable energy of growing relevance in current electric energy systems, presenting favorable wind conditions in comparison with the sites on land. However, the higher energy yield has to compensate the increment…
We present a distributed and price-based control approach for frequency regulation in power grids with nonzero line conductances. Both grid and controller are modeled as a port-Hamiltonian system, where the grid model consists of…
This paper proposes a control method for allowing aggregates of thermostatically controlled loads to provide synthetic inertia and primary frequency regulation services to the grid. The proposed control framework is fully distributed and…
An increasing penetration of renewable generation has led to reduced levels of rotational inertia and damping in the system. The consequences are higher vulnerability to disturbances and deterioration of the dynamic response of the system.…
In this paper a design of a master-slave microgrid consisting of grid-supporting current source inverters and a synchronous generator is proposed. The inverters are following the frequency of the grid imposed by the synchronous generator.…
This paper addresses the problem of output voltage regulation for multiple DC-DC converters connected to a grid, and prescribes a robust scheme for sharing power among different sources. Also it develops a method for sharing 120 Hz ripple…
This study investigates the economic and reliability benefits of improved offshore wind forecasting for grid operations along the U.S. East Coast. We introduce and evaluate a state-of-the-art, machine-learning-based offshore wind…
Inverter-based resources (IBR) have been widely studied for their advantages on the current power systems. This increase in the penetration of renewable energy has raised some concerns about the stability of the existing grid. Historically,…
The European North Sea has a vast renewable energy potential and can be a powerhouse for Europe's energy transition. However, currently there is uncertainty about how much offshore wind energy can be integrated, whether offshore grids…
Cascading failures typically occur following a large disturbance in power systems, such as tripping of a generating unit or a transmission line. Such failures can propagate and destabilize the entire power system, potentially leading to…
The preventative strategies for $N-1$ network security dominant in European networks mean that network capacity is kept free in case a line fails. If instead fast corrective actions are used to overcome network overloading when single lines…
This paper employs modal analysis to study the core inertial dynamics of governor-controlled synchronous generators (GC-SG), droop-based grid-forming (GFM) converters, and their most fundamental interactions. The results indicate that even…
This paper analyses the issue of frequency quality in low-inertia power systems. The analysis is based on a real-world large-scale low-inertia power system namely, the All-Island transmission system (AITS) of Ireland and Northern Ireland…