Mm and sub-mm waves polarimetry is the new frontier of research in Cosmic Microwave Background and Interstellar Dust studies. Polarimeters working in the IR to MM range need to be operated at cryogenic temperatures, to limit the systematic…

Instrumentation and Methods for Astrophysics · Physics 2012-04-09 Maria Salatino , Paolo de Bernardis , Silvia Masi

Providing a background discrimination tool is crucial for enhancing the sensitivity of next-generation experiments searching for neutrinoless double- beta decay. The development of high-sensitivity (< 20 eV RMS) cryogenic light detectors…

The BICEP/$\textit{Keck}$ (BK) series of cosmic microwave background (CMB) polarization experiments has, over the past decade and a half, produced a series of field-leading constraints on cosmic inflation via measurements of the "B-mode"…

The measurement of physics processes at new energy frontier experiments requires excellent spatial, time, and energy resolutions to resolve the structure of collimated high-energy jets. In a future Muon Collider, the beam-induced…

Instrumentation and Detectors · Physics 2022-10-05 S. Ceravolo , F. Colao , C. Curatolo , E. Di Meco , E. Diociaiuti , D. Lucchesi , D. Paesani , N. Pastrone , A. Saputi , I. Sarra , L. Sestini , D. Tagnani

The use of low-temperature detectors, such as cryogenic calorimeters, has pioneered the recent advancements in low-energy rare event searches. These detectors provide a low-noise environment essential for the direct detection of dark matter…

Instrumentation and Detectors · Physics 2026-02-25 Giorgio Del Castello

Cooling of particles to mK-temperatures is essential for a variety of experiments with trapped charged particles. However, many species of interest lack suitable electronic transitions for direct laser cooling. We study theoretically the…

In this paper we describe the current status of the CALDER project, which is developing ultra-sensitive light detectors based on superconductors for cryogenic applications. When we apply an AC current to a superconductor, the Cooper pairs…

Superfluid helium is a prototypical quantum liquid. As such, it has been a prominent platform for the study of quantum many body physics. More recently, the outstanding mechanical and optical properties of superfluid helium, such as low…

Instrumentation and Detectors · Physics 2025-08-28 Alexander R. Korsch , Niccolò Fiaschi , Simon Gröblacher

Using a new brand of commercially available carbon resistor we built a cryogenic thermometer with an extremely good thermal contact to its thermal environment. Because of its superior thermal contact the thermometer is insensitive to low…

Instrumentation and Detectors · Physics 2011-04-07 Nodar Samkharadze , Ashwani Kumar , Gábor A. Csáthy

Recent observations made with Advanced LIGO and Advanced Virgo have initiated the era of gravitational-wave astronomy. The number of events detected by these "2nd Generation" (2G) ground-based observatories is partially limited by noise…

Instrumentation and Detectors · Physics 2021-09-01 Christoph Reinhardt , Alexander Franke , Jörn Schaffran , Roman Schnabel , Axel Lindner

We demonstrate millikelvin thermometry of laser cooled trapped ions with high-resolution imaging. This equilibrium approach is independent of the cooling dynamics and has lower systematic error than Doppler thermometry, with \pm5 mK…

Quantum Physics · Physics 2011-06-10 B. G. Norton , E. W. Streed , M. J. Petrasiunas , A. Jechow , D. Kielpinski

The study of cold and controlled molecular ions is pivotal for fundamental research in modern physics and chemistry. Investigations into cooling molecular anions, in particular, have proven to be of key consequence for the production of…

CLOVER is an experiment which aims to detect the signature of gravitational waves from inflation by measuring the B-mode polarization of the cosmic microwave background. CLOVER consists of three telescopes operating at 97, 150, and 220 GHz.…

Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. In this…

We describe the design and calibration of an external cryogenic blackbody calibrator used for the first two flights of the Absolute Radiometer for Cosmology, Astrophysics, and Diffuse Emission (ARCADE) instrument. The calibrator consists of…

Astrophysics · Physics 2009-11-10 A. Kogut , E. Wollack , D. J. Fixsen , M. Limon , P. Mirel , S. Levin , M. Seiffert , P. M. Lubin

In this paper we give a detailed analysis of the expected sensitivity and operating conditions in the power detection mode of a hot-electron bolometer (HEB) made from a few {\mu}m$^2$ of monolayer graphene (MLG) flake which can be embedded…

Instrumentation and Methods for Astrophysics · Physics 2015-06-22 Boris S. Karasik , Christopher B. McKitterick , Daniel E. Prober

In high-sensitivity bolometers and calorimeters, the photon absorption often occurs at a finite distance from the temperature sensor to accommodate antennas or avoid the degradation of superconducting circuitry exposed to radiation. As a…

Mesoscale and Nanoscale Physics · Physics 2024-01-17 Caleb Fried , B. Jordan Russell , Ethan G. Arnault , Bevin Huang , Gil-Ho Lee , Dirk Englund , Erik A. Henriksen , Kin Chung Fong

Two-dimensional electron gases (2DEGs) with high mobility, engineered in semiconductor heterostructures host a variety of ordered phases arising from strong correlations, which emerge at sufficiently low temperatures. The 2DEG can be…

A new type of bolometer arrays sensitive in the Far Infrared and Submillimeter range has been developped and manufactured by CEA/LETI/SLIR and will be integrated in the PACS instrument onboard the Herschel Space Observatory (launch date…

Kinetic inductance bolometer (KIB) technology is a candidate for passive sub-millimeter wave and terahertz imaging systems. Its benefits include scalability into large 2D arrays and operation with intermediate cryogenics in the temperature…