English
Related papers

Related papers: Morphological Reconstruction Improves Microvessel …

200 papers

Ultrasound localization microscopy offers new radiation-free diagnostic tools for vascular imaging deep within the tissue. Sequential localization of echoes returned from inert microbubbles with low-concentration within the bloodstream…

Medical Physics · Physics 2018-04-11 Oren Solomon , Ruud J. G. van Sloun , Hessel Wijkstra , Massimo Mischi , Yonina C. Eldar

Super-resolution ultrasound (SR-US) is a powerful imaging technique for capturing microvasculature and blood flow at high spatial resolution. However, accurate microbubble (MB) localization remains a key challenge, as errors in localization…

Image and Video Processing · Electrical Eng. & Systems 2025-01-06 Sepideh K. Gharamaleki , Brandon Helfield , Hassan Rivaz

Super-resolution ultrasound imaging through microbubble (MB) localisation and tracking, also known as ultrasound localisation microscopy, allows non-invasive sub-diffraction resolution imaging of microvasculature in animals and humans. The…

Image and Video Processing · Electrical Eng. & Systems 2025-05-23 Su Yan , Clotilde Vié , Marcelo Lerendegui , Herman Verinaz-Jadan , Jipeng Yan , Martina Tashkova , James Burn , Bingxue Wang , Gary Frost , Kevin G. Murphy , Meng-Xing Tang

Super-resolution ultrasound imaging (SRUS) is an active area of research as it brings up to a ten-fold improvement in the resolution of microvascular structures. The limitations to the clinical adoption of SRUS include long acquisition…

Image and Video Processing · Electrical Eng. & Systems 2024-08-05 Arthur David Redfern , Katherine G. Brown

Super-resolution ultrasound (SRUS) imaging through localising and tracking sparse microbubbles has been shown to reveal microvascular structure and flow beyond the wave diffraction limit. Most SRUS studies use standard delay and sum (DAS)…

High frame rate 3-D ultrasound imaging technology combined with super-resolution processing method can visualize 3-D microvascular structures by overcoming the diffraction limited resolution in every spatial direction. However, 3-D…

Ultrasound super-localization microscopy techniques presented in the last few years enable non-invasive imaging of vascular structures at the capillary level by tracking the flow of ultrasound contrast agents (gas microbubbles). However,…

Tissues and Organs · Quantitative Biology 2016-08-10 Avinoam Bar-Zion , Charles Tremblay-Darveau , Oren Solomon , Dan Adam , Yonina C. Eldar

The purpose of this study is to enable in-vivo three-dimensional (3-D) ultrasound localization microscopy (ULM) of posterior ocular microvasculature using a 256-channel system and a 1024-element matrix array, and to overcome limitations of…

Super-Resolution Ultrasound (SRUS) imaging through localising and tracking microbubbles, also known as Ultrasound Localisation Microscopy (ULM), has demonstrated significant potential for reconstructing microvasculature and flows with…

Image and Video Processing · Electrical Eng. & Systems 2025-03-26 Jipeng Yan , Qingyuan Tan , Shusei Kawara , Jingwen Zhu , Bingxue Wang , Matthieu Toulemonde , Honghai Liu , Ying Tan , Meng-Xing Tang

Recently, super-resolution ultrasound imaging with ultrasound localization microscopy (ULM) has received much attention. However, ULM relies on low concentrations of microbubbles in the blood vessels, ultimately resulting in long…

Super-resolution ultrasound imaging relies on the sub-wavelength localization of microbubble contrast agents. By tracking individual microbubbles, the velocity and flow within microvessels can be estimated. However, a 2D super-resolution…

Recently, the Magnetic Resonance Imaging (MRI) images have limited and unsatisfactory resolutions due to various constraints such as physical, technological and economic considerations. Super-resolution techniques can obtain high-resolution…

Computer Vision and Pattern Recognition · Computer Science 2019-02-14 Yinghua Li , Bin Song , Jie Guo , Xiaojiang Du , Mohsen Guizani

Ultrasound localization microscopy has enabled super-resolution vascular imaging through precise localization of individual ultrasound contrast agents (microbubbles) across numerous imaging frames. However, analysis of high-density regions…

Signal Processing · Electrical Eng. & Systems 2018-12-14 Ruud J. G. van Sloun , Oren Solomon , Matthew Bruce , Zin Z. Khaing , Hessel Wijkstra , Yonina C. Eldar , Massimo Mischi

Ultrasound Localization Microscopy can resolve the microvascular bed down to a few micrometers. To achieve such performance microbubble contrast agents must perfuse the entire microvascular network. Microbubbles are then located…

Computer Vision and Pattern Recognition · Computer Science 2023-10-13 Léo Milecki , Jonathan Porée , Hatim Belgharbi , Chloé Bourquin , Rafat Damseh , Patrick Delafontaine-Martel , Frédéric Lesage , Maxime Gasse , Jean Provost

Identifying and visualizing vasculature within organs and tumors has major implications in managing cardiovascular diseases and cancer. Contrast-enhanced ultrasound scans detect slow-flowing blood, facilitating non-invasive perfusion…

Medical Physics · Physics 2018-09-18 Avinoam Bar-Zion , Oren Solomon , Charles Tremblay-Darveau , Dan Adam , Yonina C. Eldar

High resolution transcranial ultrasound imaging in humans has been a persistent challenge for ultrasound due to the imaging degradation effects from aberration and reverberation. These mechanisms depend strongly on skull morphology and they…

Medical Physics · Physics 2018-11-28 Danai E. Soulioti , David Espíndola , Paul A. Dayton , Gianmarco Pinton

Super-resolution ultrasound (SRUS) technology has overcome the resolution limitations of conventional ultrasound, enabling micrometer-scale imaging of microvasculature. However, due to the nature of imaging principles, three-dimensional…

Computer Vision and Pattern Recognition · Computer Science 2026-04-07 Jincao Yao , Ke Zhang , Yahan Zhou , Jiafei Shen , Jie Liu , Mudassar Ali , Bojian Feng , Jiye Chen , Jinlong Fan , Ping Liang , Dong Xu

Super-Resolution Ultrasound (SRUS) through localizing spatially isolated microbubbles has been demonstrated to overcome the wave diffraction limit and reveal the microvascular structure and flow information at the microscopic scale.…

Signal Processing · Electrical Eng. & Systems 2022-06-09 B. Wang , K. Riemer , M. Toulemonde , J. Yan , X. Zhou , M. Tang

Ultrasound Localization Microscopy (ULM) has recently enabled the mapping of the cerebral vasculature in vivo with a resolution ten times smaller than the wavelength used, down to ten microns. However, with frame rates up to 20.000 frames…

Medical Physics · Physics 2023-10-23 Erwan Hardy , Jonathan Poree , Hatim Belgharbi , Chloe Bourquin , Frederic Lesage , Jean Provost

Super-resolution ultrasound imaging has been so far achieved in 3-D by mechanically scanning a volume with a linear probe, by co-aligning multiple linear probes, by using multiplexed 3-D clinical ultrasound systems, or by using 3-D…

‹ Prev 1 2 3 10 Next ›