Related papers: Toward the Frontiers of Particle Physics With the …
The E989 Muon $g-2$ Experiment at Fermilab aims to measure the muon magnetic anomaly, $a_\mu$, to an unprecedented precision of 140 parts per billion (ppb), representing a four-fold improvement over the current best measurement, achieved at…
The Muon g-2 Experiment (E989) at Fermilab is seeking to measure the anomalous magnetic moment of muon ($a_{\mu}$) with a precision of 140 parts-per-billion (ppb) and aiming to resolve the discrepancy between the E821 measurement and the…
The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was…
The Muon g-2 Experiment (E989) at Fermilab measures the muon magnetic anomaly, aiming to resolve the greater than 3$\sigma$ discrepancy between the previous measurement and the Standard Model calculation with an improved precision of 140…
The magnetic moment is a fundamental property of particles. The measurement of these magnetic moments and the comparison with the values predicted by the standard model of particle physics is a way to test our understanding of the…
The Muon g-2 experiment E989 at Fermilab measures the anomalous magnetic moment of the muon $a_\mu$ with improved precision compared to the Brookhaven (E821) experiments. The Brookhaven results are in tension with the Standard Model by more…
The muon magnetic anomaly, $a_{\mu}$, is a powerful test of the Standard Model of particle physics. A new experiment at Fermilab has recently measured $a_{\mu}$ with unprecedented precision, confirming the results of the earlier Brookhaven…
The Muon $g-2$ experiment at Fermilab aims to measure the muon anomalous magnetic moment with an unprecedented precision of 140 parts per billion (ppb). Data collection concluded in June 2023, and analysis of the largest dataset (2021-2023)…
The Fermi National Accelerator Laboratory (FNAL) Muon $g-2$ Experiment has measured the positive muon magnetic anomaly $a_{\mu} \equiv (g_{\mu}-2)/2$ with a precision of 0.46 parts per million, with data collected during its first physics…
The current $\sim3.5\sigma$ discrepancy between the experimental measurement and theoretical prediction of the muon magnetic anomaly, $a_{\mu}$, stands as a potential indication of the existence of new physics. The Muon $g-2$ experiment at…
A new experiment at Fermilab will measure the anomalous magnetic moment of the muon with a precision of 140 parts per billion (ppb). This measurement is motivated by the results of the Brookhaven E821 experiment that were first released…
This paper will cover the physics and methods behind Fermilab's Muon g-2 Experiment, along with the long-awaited results from Run-1. The experiment was undertaken to resolve the tension between the Standard Model and the previous…
The Muon g-2 Experiment at Fermilab will measure the anomalous magnetic moment of the muon to a precision of 140 parts per billion, which is a factor of four improvement over the previous E821 measurement at Brookhaven. The experiment will…
The precise measurement of the muon anomalous magnetic moment $a_\mathrm{\mu}$ has stimulated much theoretical and experimental efforts over more than six decades. The last experiment at Brookhaven National Laboratory, Upton, NY, USA…
We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_\mu \equiv (g_\mu-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of…
The muon anomalous magnetic moment, $a_\mu = (g-2)/2$, is a low-energy observable which can be both measured and computed with very high precision, making it an excellent test of the Standard Model (SM) and a sensitive probe of new physics.…
The Muon (g-2) Experiment, E989 at Fermilab, will measure the muon anomalous magnetic moment a factor-of-four more precisely than was done in E821 at the Brookhaven National Laboratory AGS. The E821 result appears to be greater than the…
We present details on a new measurement of the muon magnetic anomaly, $a_\mu = (g_\mu -2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$…
The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment $a_{\mu}$ . This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation…
This article reviews the muon g-2 experiment, a cornerstone in precision tests of the Standard Model of particle physics. The experiment measures the anomalous magnetic moment of the muon with unprecedented accuracy, seeking potential…