English
Related papers

Related papers: A sub-micron resolution, bunch-by-bunch beam traje…

200 papers

In order to double the positron injection rate into the KEKB ring, a two-bunch acceleration scheme has been studied at the linac, in which bunches separated by 96 ns are accelerated in 50 Hz. In this scheme the stabilization of energy and…

Accelerator Physics · Physics 2010-11-15 K. Furukawa , N. Kamikubota , T. Suwada , T. Obata

Pulse-to-pulse orbit jitter, if not controlled, can drastically degrade the luminosity in future linear colliders. The second goal of the ATF2 project at the KEK accelerator test facility is to stabilise the vertical beam position down to…

Accelerator Physics · Physics 2011-10-25 Javier Resta-Lopez , Glenn Christian

We report the design, operation and performance of a high-resolution, low-latency, bunch-by-bunch feedback system for nano-beam stabilisation. The system employs novel, ultra-low quality-factor cavity beam position monitors (BPMs), a…

Accelerator Physics · Physics 2022-03-14 D. R. Bett , N. Blaskovic Kraljevic , T. Bromwich , P. N. Burrows , G. B. Christian , C. Perry , R. Ramjiawan

A double kicker system which extracts the ultra-low emittance multi-bunch beam stably from ATF damping ring was developed. The performance of the system was studied comparing an orbit jitter with single kicker extraction in single bunch…

Accelerator Physics · Physics 2007-05-23 T. Imai , K. Nakai , H. Hayano , J. Urakawa , N. Terunuma

A system for bunch-by-bunch detection of transverse proton and antiproton coherent oscillations in the Tevatron is described. It is based on the signal from a single beam-position monitor located in a region of the ring with large amplitude…

Accelerator Physics · Physics 2015-03-19 Giulio Stancari , Alexander Valishev

A fully digital beam position and phase measurement (BPPM) system was designed for the linear accelerator (LINAC) in Accelerator Driven Sub-critical System (ADS) in China. Phase information is obtained from the summed signals from four…

Instrumentation and Detectors · Physics 2019-09-25 Xingshun Gao , Lei Zhao , Jinxin Liu , Zouyi Jiang , Xiaofang Hu , Shubin Liu , Qi An

A system was developed for bunch-by-bunch detection of transverse proton and antiproton coherent oscillations based on the signal from a single beam-position monitor (BPM) located in a region of the ring with large amplitude functions. The…

Accelerator Physics · Physics 2012-02-02 G. Stancari , A. Valishev , A. Semenov

The Accelerator Test Facility 2 (ATF2) is a scaled demonstrator system for final focus beam lines of linear high energy colliders. This paper describes the high resolution cavity beam position monitor (BPM) system, which is a part of the…

Real-time, bunch-by-bunch monitoring of transverse position, longitudinal phase, and bunch length is crucial for beam control in diffraction-limited storage rings, where complex collective dynamics pose unprecedented diagnostic challenges.…

Accelerator Physics · Physics 2026-01-28 Can Liu , Xing Yang , Youming Deng , Qingqing Duan , Yongbin Leng

Many advanced techniques have been developed, tested and implemented in the last decades in almost all circular accelerators across the world to measure the linear optics. However, the greater availability and accuracy of beam diagnostics…

Accelerator Physics · Physics 2018-04-18 Andrea Franchi

In this paper, some preliminary considerations on the feedback systems for FCC-ee are developed. Bunch-by-bunch feedback systems have been designed in the last years for other e+/e- colliders like PEP-II, KEKB, DAFNE, SuperB and SuperKEKB.…

Accelerator Physics · Physics 2017-04-25 Alessandro Drago

Shanghai Synchrotron Radiation Facility (SSRF), is one of the third-generation high-beam current (3.5 GeV) synchrotron light sources. In the storage ring of SSRF, multi-bunch instabilities would increase beam emittance and energy spread,…

Instrumentation and Detectors · Physics 2019-07-25 Jinxin Liu , Lei Zhao , Linsong Zhan , Shubin Liu , Qi An

BPM (Beam Position Measurement) system is one of the most important beam diagnostic instruments in accelerators. A fully digital BPM (DBPM) has been designed for SSRF (Shanghai Synchrotron Radiation Facility). As Analog-to-Digital Converter…

Instrumentation and Detectors · Physics 2019-09-30 Weihao Wu , Lei Zhao , Erlei Chen , Shubin Liu , Qi An

The bunch-by-bunch BPM signal array has to be reshaped into a turn-by-turn (TBT) matrix in order to make the TBT beam position information of a single bunch available for further data analysis, such as via the Fourier transform to obtain…

Accelerator Physics · Physics 2007-05-23 Xi Yang , Charles M. Ankenbrandt , James Lackey , Vic Scarpine

The low energy part of the FAST linear accelerator based on 1.3 GHz superconducting RF cavities was successfully commissioned. During commissioning, beam based model dependent methods were used to correct linear lattice and trajectory.…

Accelerator Physics · Physics 2017-09-15 A. Romanov , D. Edstrom , A. Halavanau

Coupled-bunch instabilities excited by the interaction of the particle beam with its surroundings can seriously limit the performance of circular particle accelerators. These instabilities can be cured by the use of active feedback systems…

Accelerator Physics · Physics 2016-01-21 M. Lonza , H. Schmickler

This article presents a method that uses turn-by-turn beam position data and k-modulation data to measure the calibration factors of beam position monitors in high energy accelerators. In this method, new algorithms have been developed to…

Accelerator Physics · Physics 2021-03-09 Javier Fernando Cardona

We use beam position measurements over the first part of the AWAKE electron beamline, together with beamline modeling, to deduce the beam average momentum and to predict the beam position in the second part of the beamline. Results show…

A system for bunch-by-bunch detection of transverse proton and antiproton coherent oscillations in the Fermilab Tevatron collider is described. It is based on the signal from a single beam-position monitor located in a region of the ring…

Accelerator Physics · Physics 2013-12-19 G. Stancari , A. Valishev , S. M. White

Beam-line equipment was upgraded for experiment E08-027 (g2p) in Hall A at Jefferson Lab. Two beam position monitors (BPMs) were necessary to measure the beam position and angle at the target. A new BPM receiver was designed and built to…

‹ Prev 1 2 3 10 Next ›