The operating principle and performances of the Multi-layer Thick Gaseous Electron Multiplier (M-THGEM) is presented. The M-THGEM is a novel hole-type gaseous electron multiplier produced by multi-layer printed circuit board technology; it…

Instrumentation and Detectors · Physics 2016-06-24 M. Cortesi , S. Rost , W. Mittig , Y. Ayyad Limonge , D. Bazin , J. Yurkon , A. Stolz

The occurrence of electrical discharges in gas detectors restricts their dynamic range and degrades their performance. Among the different methods developed to mitigate discharge effects, the use of resistive materials in the detector…

Instrumentation and Detectors · Physics 2022-11-16 Abhik Jash , Luca Moleri , Shikma Bressler

At NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are…

A new concept for a hybrid structure gaseous detector module with ion backflow suppression for the time projection chamber in a future circular collider is presented. It is a hybrid structure cascaded Gas Electron Multiplier (GEM) with a…

Instrumentation and Detectors · Physics 2017-04-03 YuLian Zhang , HuiRong Qi , BiTao Hu , Hai-Yun Wang , Qun Ou-Yang , Yuan-Bo Chan , Jian Zhang , Zhi-Wen Wen

The Yale-Weizmann collaboration aims to develop a low-radioactivity (low-background) cryogenic noble liquid detector for Dark-Matter (DM) search in measurements to be performed deep underground as for example carried out by the XENON…

Instrumentation and Detectors · Physics 2007-06-11 M. Gai , D. N. McKinsey , K. Ni , D. A. R. Rubin , T. Wongjirad , R. Alon , A. Breskin , M. Cortesi , J. Miyamoto

Measurements and numerical simulations on the charge transfer in Gas Electron Multiplier (GEM) foils are presented and their implications for the usage of GEM foils in Time Projection Chambers are discussed. A small test chamber has been…

Instrumentation and Detectors · Physics 2009-09-29 M. Killenberg , S. Lotze , J. Mnich , S. Roth , R. Schulte , B. Sobloher , W. Struczinski , M. Tonutti

The use of gaseous Time Projection Chambers enables the detection and the detailed study of rare events due to particles interactions with the atoms of the gas with energy releases as low as a few keV. Due to this capability, these…

We study the performance of two-phase avalanche detectors based on Gas Electron Multipliers (GEMs) and operated in an electron-avalanching mode in Ar and Xe. Emission, gain, energy resolution and stability characteristics of the detectors…

Instrumentation and Detectors · Physics 2009-11-11 A. Bondar , A. Buzulutskov , A. Grebenuk , D. Pavlyuchenko , R. Snopkov , Y. Tikhonov

For its physics program with a high-intensity hadron beam of up to 2e7 particles/s, the COMPASS experiment at CERN requires tracking of charged particles scattered by very small angles with respect to the incident beam direction. While good…

THick Gas Electron Multipliers (THGEMs) are robust and high gain Micro Pattern Gaseous Detectors which are economically manufactured by standard drilling and etching of thin printed circuit boards. In this paper, we present our recent…

Instrumentation and Detectors · Physics 2022-12-20 Promita Roy , Purba Bhattacharya , Vishal Kumar , Supratik Mukhopadhyay , Nayana Majumdar , Sandip Sarkar

New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors…

In triple-GEM detectors, the segmentation of GEM foils in electrically independent sectors allows reducing the probability of discharge damage to the detector and improving the detector rate capability; however, a segmented foil presents…

Charging-up processes affecting gain stability in Thick Gas Electron Multipliers (THGEM) were studied with a dedicated simulation toolkit. Integrated with Garfield++, it provides an effective platform for systematic phenomenological studies…

It is well known and has been shown that the gain performance of Gaseous Electron Multipliers (GEM) depends on the size of the holes. With an optical scanner it is possible to measure the dimensions of the holes, and to predict the…

Instrumentation and Detectors · Physics 2021-04-28 Erik Brücken , Jouni Heino , Timo Hildén , Matti Kalliokoski , Vladyslav Litichevskyi , Raimo Turpeinen , Dezső Varga

This work is proposing and exploring the use of multichannel readout electronics, already used in quality assurance for gain uniformity studies, to measure the uniformity of the induction gap in GEM based detectors. The measurement will…

Instrumentation and Detectors · Physics 2021-10-27 Mohit Gola

A thick gas electron multiplier is considered for radiation-hard detectors (hadron calorimeter). There was carried out technological and design study to optimize the element structure. The measurements results and the next plans are…

Instrumentation and Detectors · Physics 2009-09-30 V. Inshakov , V. Kryshkin , N. Kuzmin , V. Skvortsov , S. Sychkov , A. Sytin

The new beam profile measurement for the Antiproton Decelerator (AD) at CERN is based on a single Gas Electron Multiplier (GEM) with a 2D readout structure. This detector is very light (~0.4% X0), and measures horizontal and vertical…

Instrumentation and Detectors · Physics 2012-03-20 Serge Duarte Pinto , Rhodri Jones , Leszek Ropelewski , Jens Spanggaard , Gerard Tranquille

Micro-Pattern Gaseous Detectors (MPGDs) such as Micromegas or GEM are used in particle physics experiments for their capabilities in particle tracking at high rates. Their excellent position resolutions are well known but their energy…

Instrumentation and Detectors · Physics 2011-07-19 T. Zerguerras , B. Genolini , V. Lepeltier , J. Peyre , J. Pouthas , P. Rosier

In this paper, measurement results and experimental methodology are presented on the determination of multiplication distributions of avalanches initiated by single electron in GEM foils. The measurement relies on the amplification of…

Instrumentation and Detectors · Physics 2016-10-26 Andras Laszlo , Gergo Hamar , Gabor Kiss , Dezso Varga

Earlier we have developed and successfully tested a RICH detector prototype consisting in a CsI coated triple GEM operated in gas flushed mode In the given work, a modified version of this detector for a completely different application -…

Instrumentation and Detectors · Physics 2018-11-14 G. Volpe , V. Peskov