English
Related papers

Related papers: A layered single-side readout DOI TOF-PET detector

200 papers

Coincidence time resolution (CTR) in time-of-flight positron emission tomography (TOF-PET) has significantly improved with advancements in scintillators, photodetectors, and readout electronics. Achieving a CTR of 100 ps remains challenging…

Instrumentation and Detectors · Physics 2024-12-25 Yuya Onishi , Ryosuke Ota

Current clinical PET systems utilize detectors where the scintillator typically contains single elements of 3 - 6 mm width and about 20 mm height. While providing good TOF performance, this design limits the spatial resolution and causes…

Instrumentation and Detectors · Physics 2022-11-17 Florian Mueller , Stephan Naunheim , Yannick Kuhl , David Schug , Torsten Solf , Volkmar Schulz

Modeling the timing performance of light-based radiation detectors accurately is essential for optimizing time-of-flight positron emission tomography (TOF-PET). We present an analytic framework that combines existing models to predict the…

Instrumentation and Detectors · Physics 2025-10-08 Nicolaus Kratochwil , Emilie Roncali , Gerard Arino-Estrada

The aim of this work is to show the potential capabilities of monolithic crystals coupled to large SiPM arrays, to be considered as detector blocks for PET scanners enabling Time Of Flight (TOF) capabilities. Monolithic blocks allow one to…

In this paper we prove that the choice of a suitable treatment of the scintillator surfaces, along with suitable photodetectors electronics and specific algorithms for raw data analysis, allow to achieve an optimal tradeoff between energy,…

Medical Physics · Physics 2012-03-02 Luigi Cosentino , Paolo Finocchiaro , Alfio Pappalardo , Franco Garibaldi

Semi monolithic detector designs with a series of stacked thin monolithic scintillator plates and side readout are an attractive approach for potentially achieving very high performance in a positron emission tomography (PET) scanner. In…

Instrumentation and Detectors · Physics 2025-02-12 Shiv K. Subedi , Simon R. Cherry , Yi Qiang , Peng Peng

A system based on commercially available items, such as a laser diode, emitting in the visible range $\sim 400$ nm,and multimode fiber patches, fused fiber splitters and optical switches may be assembled,for time calibration of…

Instrumentation and Detectors · Physics 2016-06-01 M. Bonesini , R. Bertoni , A. deBari , M. Rossella

Organ-specific, targeted Field-of-View (FoV) Positron Emission Tomography (PET)/Magnetic Resonance Imaging (MRI) inserts are viable solutions for a number of imaging tasks where whole-body PET/MRI systems lack the necessary sensitivity and…

Instrumentation and Detectors · Physics 2019-09-19 J. M. C. Brown , S. E. Brunner , D. R. Schaart

The ClearMind project aims to develop a TOF-PET position-sensitive detection module optimized for time and spatial resolutions and detection efficiency. For this, we use a 59 mm $\times$ 59 mm $\times$ 5 mm monolithic PbWO$_4$ (PWO)…

Instrumentation and Detectors · Physics 2024-06-28 A. Galindo-Tellez , V. Sharyy , C. -H. Sung , M. Follin , L. Cappellugola , S. Curtoni , M. Dupont , C. Morel , D. Breton , J. Maalmi , D. Yvon

Timing-pick up detectors with excellent timing resolutions are essential in many modern nuclear physics experiments. Aiming to develop a Time-Of-Flight system with precision down to about 10 ps, we have made a systematic study of the timing…

Instrumentation and Detectors · Physics 2016-04-19 J. W. Zhao , B. H. Sun , I. Tanihata , S. Terashima , L. H. Zhu , A. Enomoto , D. Nagae , T. Nishimura , S. Omika , A. Ozawa , Y. Takeuchi , T. Yamaguchi

PET is a functional imaging method that visualizes metabolic processes. TOF information can be derived from coincident detector signals and incorporated into image reconstruction to enhance the SNR. PET detectors are typically assessed by…

Instrumentation and Detectors · Physics 2025-04-24 Stephan Naunheim , Luis Lopes de Paiva , Vanessa Nadig , Yannick Kuhl , Stefan Gundacker , Florian Mueller , Volkmar Schulz

Monolithic crystals are examined as an alternative to segmented scintillator arrays in positron emission tomography (PET). Monoliths provide good energy, timing and spatial resolution including intrinsic depth of interaction (DOI) encoding.…

Medical Physics · Physics 2018-12-05 Florian Müller , David Schug , Patrick Hallen , Jan Grahe , Volkmar Schulz

Aim: Investigate whether a time walk assessment derived from crystal light sharing and multi-photon time stamps can improved the TOF resolution. Method: Monte Carlo simulations were performed for SiPM (FBK-NUV-HD) coupled to conventional…

Instrumentation and Detectors · Physics 2020-10-12 Stephan Walrand , Michel Hesse , François Jamar

Single photon avalanche diode (SPAD) arrays have proven themselves as serious candidates for time of flight positron emission tomography (PET). Discrete readout schemes mitigate the low-noise requirements of analog schemes and offer very…

Instrumentation and Detectors · Physics 2018-06-28 M. -A. Tétrault , É. Desaulniers Lamy , A. Boisvert , C. Thibaudeau , F. Dubois , R. Fontaine , J. -F. Pratte

We present the development of a single-photon detector and the connected read-out electronics. This `hybrid' detector is based on a vacuum tube, transmission photocathode, microchannel plate and a pixelated CMOS read-out anode encapsulating…

Instrumentation and Detectors · Physics 2022-07-06 J. A. Alozy , N. V. Biesuz , M. Campbell , V. Cavallini , A. Cotta Ramusino , M. Fiorini , M. Guarise , X. Llopart Cudie

Depth-of-interaction (DOI) encoding is an effective strategy for reducing parallax error and preserving spatial resolution in positron emission tomography (PET), particularly in compact small-animal scanners. To enable efficient…

Medical Physics · Physics 2026-03-10 Satzhan Sitmukhambetov , Junwei Du , Mingwu Jin , Yujie Chi

A 760 $\times$ 760 $\times$ 30 mm$^3$ plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and $\gamma$ rays. A position-independent…

Instrumentation and Detectors · Physics 2016-08-03 Shu-wen Tang , Yu-hong Yu , Yong Zhou , Zhi-yu Sun , Xue-heng Zhang , Shi-tao Wang , Ke Yue , Long-xiang Liu , Fang Fang , Duo Yan , Yu Sun , Zhao-min Wang

Most of the time-of-flight systems as well as the fast interaction trigger detectors have large surfaces and the principal requirements for the above mentioned detectors is a good time resolution of the order 100-200ps. The easiest solution…

Instrumentation and Detectors · Physics 2024-01-18 Varlen Grabski

PETALO (a Positron Emission Tof Apparatus based on Liquid xenOn) is a new approach for Positron Emission Tomography scanners, based on liquid xenon. The PETALO detector aims at capturing the light produced by the scintillation in LXe taking…

To measure light emission pattern in scintillator, higher sensitivity and faster response are required to photo detector. Such as single photon avalanche diode (SPAD), conventional pixelated photo detector is operated at Geiger avalanche…

‹ Prev 1 2 3 10 Next ›