English
Related papers

Related papers: A $4\pi$ Fluorescence Detection Region for Colline…

200 papers

Illuminating or imaging samples from a broad angular range is essential in a wide variety of computational 3D imaging and resolution-enhancement techniques, such as optical projection tomography (OPT), optical diffraction tomography (ODT),…

To effectively apply passive speckle reduction methods, it is essential to use an illumination system that maximally exploits the non-ideal temporal coherence and angular diversity (spatial coherence reduction) of laser light. This study…

Optics · Physics 2025-04-28 A. Lapchuk , O. Prygun , D. Manko , I. Gorbov , Y. Morozov

Optical two-dimensional coherent spectroscopy (2DCS) is a powerful ultrafast spectroscopic technique that can greatly benefit from the unique features of a femtosecond laser operating at a kHz repetition rate. However, isolating specific…

Optics · Physics 2024-08-08 Stephen Revesz , Rustam Gatamov , Adolfo Misiara , Hebin Li

Fluorescence imaging is an essential diagnostic tool in many fields, but diffraction-limited optical imaging at depth is limited by scattering. Here, we present a method based on multiple random illuminations, combined with a computational…

Optics · Physics 2026-03-30 Lei Zhu , Tengfei Wu , Bernhard Rauer , Hilton B. de Aguiar , Sylvain Gigan

Traditional glass-based optics are typically optimized for narrow spectral bands, such as the visible (400-700nm) or shortwave infrared (1000-1800nm). While the emergence of VIS-SWIR sensors (400-1700nm) offers transformative potential,…

Image and Video Processing · Electrical Eng. & Systems 2026-05-04 Vishwanath Saragadam , Niki Nezakati , Amit Roy-Chowdhury , Vivek Boominathan

We present total and specular reflectance measurements of various materials that are commonly (and uncommonly) used to provide baffling and/or to minimize the effect of stray light in optical systems. More specifically, we investigate the…

Instrumentation and Methods for Astrophysics · Physics 2015-06-22 Jennifer L. Marshall , Patrick Williams , Jean-Philippe Rheault , Travis Prochaska , Richard D. Allen , D. L. DePoy

Diffractive/refractive optics, such as Phase Fresnel Lenses (PFL's), offer the potential to achieve excellent imaging performance in the x-ray and gamma-ray photon regimes. In principle, the angular resolution obtained with these devices…

We present a rapid-scanning approach to fluorescence-detected two-dimensional electronic spectroscopy that combines acousto-optic phase-modulation with digital lock-in detection. The approach shifts the signal detection window to suppress…

We consider using toroidal curved detectors to improve the performance of imaging optical systems. We demonstrate that some optical systems have an anamorphic field curvature. We consider an unobscured re-imaging three-mirror anastigmat as…

Instrumentation and Methods for Astrophysics · Physics 2018-06-22 Eduard Muslimov , Emmanuel Hugot , Marc Ferrari , Thibault Behaghel , Gerard R. Lemaitre , Melanie Roulet , Simona Lombardo

Fluorescence detection, either involving propagating or near-field emission, is widely being used in spectroscopy, sensing and microscopy. Total internal reflection fluorescence (TIRF) confines fluorescence excitation by an evanescent…

Quantitative Methods · Quantitative Biology 2020-06-24 Martin Oheim , Adi Salomon , Maia Brunstein

A coherent, short-length reference arm reflectometer, which utilizes a 76-MHz repetition rate mode-locked fiber laser, was investigated experimentally for long fiber links (> 10 km). The reflectometer combines the advantages of optical…

Instrumentation and Detectors · Physics 2019-08-05 P. Cho , Y. Leng , P. Petruzzi , M. Morris , G. Baumgartner , J. Goldhar

We report the development of a detection optics for the integration of Raman scattering and scanning probe microscopy at low temperature based on a parabolic mirror. In our set-up half of the paraboloid mirror covers a solid angle of $\pi$…

Instrumentation and Detectors · Physics 2018-05-09 N. Chelwani , D. Hoch , D. Jost , B. Botka , J. -R. Scholz , R. Richter , M. Theodoridou , F. Kretzschmar , T. Böhm , K. Kamarás , R. Hackl

Fluorescence Correlation Spectroscopy (FCS) yields measurement parameters (number of molecules, diffusion time) that characterize the concentration and kinetics of fluorescent molecules within a supposedly known observation volume. Absolute…

Biological Physics · Physics 2011-12-23 Charles Edouard Leroux , Irène Wang , Jacques Derouard , Antoine Delon

Conventional LIDAR systems require hundreds or thousands of photon detections to form accurate depth and reflectivity images. Recent photon-efficient computational imaging methods are remarkably effective with only 1.0 to 3.0 detected…

Applications · Statistics 2019-11-13 Joshua Rapp , Vivek K Goyal

Background-free fluorescence detection in multidimensional electronic spectroscopy promises high sensitivity compared to conventional approaches. Here we explore the sensitivity limits of multidimensional electronic spectroscopy. We present…

Chemical Physics · Physics 2022-10-18 Amitav Sahu , Vivek N. Bhat , Sanjoy Patra , Vivek Tiwari

Angular filter refractometry is an optical diagnostic that measures absolute contours of line-integrated density gradient by placing a filter with alternating opaque and transparent zones in the focal plane of a probe beam, which produce…

Plasma Physics · Physics 2023-11-30 P. V. Heuer , D. Haberberger , S. T. Ivancic , C. A. Walsh , J. R. Davies

High-speed multiplex imaging of fluorescent probes is limited by a combination of spectral resolution, sensitivity, high cost and low light throughput of detectors, and filters. In this work, we present a hyperspectral detection system…

Fourier ptychographic (FP) microscope is a coherent imaging method that can synthesize an image with a higher bandwidth using multiple low-bandwidth images captured at different spatial frequency regions. The method's demand for multiple…

Optics · Physics 2016-03-25 Jaebum Chung , Hangwen Lu , Xiaoze Ou , Haojiang Zhou , Changhuei Yang

A single photon counting system has been developed for efficient detection of forward emitted fluorescence photons at the Experimental Storage Ring (ESR) at GSI. The system employs a movable parabolic mirror with a central slit that can be…

We present methods and results of the testing of an inexpensive home-made diffraction limited lens system, the design of which was proposed in a recent paper and which has since been used (with slight alterations) by several research…

Optics · Physics 2007-05-23 P Baranowski , J Zacks , G Hechenblaikner , C J Foot
‹ Prev 1 2 3 10 Next ›