Related papers: Revised performance parameters of the ZEPLIN-III d…
The recently reported result from XENON1T experiment indicates that there is an excess with $3.5\sigma$ significance in the electronic recoil events. Interpreted as new physics, new sources are needed to account for the electronic…
The XENON1T dark matter experiment recently reported 0.65 ton-year exposure measurement on electron recoils , which shows an excess in $2\sim 3$ KeV recoils above the detector background. In this paper we present a Pseudo-Dirac dark matter…
We determine constraints on sterile neutrino warm dark matter through direct detection experiments, taking XENON100, XENON1T and DARWIN as examples. If keV-scale sterile neutrinos scatter inelastically with bound electrons of the target…
Elastic scattering off nuclei in target detectors, involving interactions with dark matter and coherent elastic neutrino nuclear recoil (CE$\nu$NS), results in the deposition of low energy within the nuclei, dissipating rapidly through a…
In this letter we point out the possibility to study new physics in the neutrino sector using dark matter detectors based on liquid xenon. These are characterized by very good spatial resolution and extremely low thresholds for electron…
We perform a low-mass dark matter search using an exposure of 30\,kg$\times$yr with the XENON100 detector. By dropping the requirement of a scintillation signal and using only the ionization signal to determine the interaction energy, we…
We consider a scenario in which dark matter particles are accelerated to semi-relativistic velocities through their scattering with the Diffuse Supernova Neutrino Background. Such a subdominant, but more energetic dark matter component can…
We report an in-situ measurement of the nuclear recoil (NR) scintillation decay time constant in liquid xenon (LXe) using the XMASS-I detector at the Kamioka underground laboratory in Japan. XMASS-I is a large single-phase LXe scintillation…
The LUX-ZEPLIN (LZ) experiment aims to detect rare interactions between dark matter particles and xenon. Although the detector is designed to be the most sensitive to GeV/$c^2$--TeV/$c^2$ Weakly Interacting Massive Particles (WIMPs), it is…
We report on WIMP search results of the XENON100 experiment, combining three runs summing up to 477 live days from January 2010 to January 2014. Data from the first two runs were already published. A blind analysis was applied to the last…
The ReD experiment measured the ionization yield Qy of argon for nuclear recoils in the 2-10 keV range using a dual-phase Time Projection Chamber irradiated with neutrons from a Cf-252 fission source. The measurement extends coverage below…
We report on a search for weakly interacting massive particle (WIMP) dark matter (DM) via elastic DM-xenon-nucleus interactions in the XENONnT experiment. We combine datasets from the first and second science campaigns resulting in a total…
Coherent elastic neutrino-nucleus scattering (CEvNS) provides a unique probe for neutrino properties Beyond the Standard Model (BSM) physics. REactor neutrino LIquid xenon Coherent Scattering experiment (RELICS), a proposed reactor neutrino…
Now that conventional weakly interacting massive particle (WIMP) dark matter searches are approaching the neutrino floor, there has been a resurgence of interest in detectors with sensitivity to nuclear recoil directions. A large-scale…
The search for a novel technology able to detect and reconstruct nuclear recoil events in the keV energy range has become more and more important as long as vast regions of high mass WIMP-like Dark Matter candidate have been excluded.…
We present the first measurement of nuclear recoils from solar $^8$B neutrinos via coherent elastic neutrino-nucleus scattering with the XENONnT dark matter experiment. The central detector of XENONnT is a low-background, two-phase time…
Amplifying the phonon signal in a semiconductor dark matter detector can be accomplished by operating at high voltage bias and converting the electrostatic potential energy into Luke-Neganov phonons. This amplification method has been…
The development of low-threshold detectors for the study of coherent elastic neutrino-nucleus scattering and for the search for light dark matter necessitates methods of low-energy calibration. We suggest this can be provided by the nuclear…
We consider the absorption by bound electrons of dark matter in the form of dark photons and axion-like particles, as well as of dark photons from the Sun, in current and next-generation direct detection experiments. Experiments sensitive…
The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We present a…