Related papers: Noise2Filter: fast, self-supervised learning and r…
Current self-supervised denoising techniques achieve impressive results, yet their real-world application is frequently constrained by substantial computational and memory demands, necessitating a compromise between inference speed and…
Recovering a high-quality image from noisy indirect measurements is an important problem with many applications. For such inverse problems, supervised deep convolutional neural network (CNN)-based denoising methods have shown strong…
In the intention of minimizing excessive X-ray radiation administration to patients, low-dose computed tomography (LDCT) has become a distinct trend in radiology. However, while lowering the radiation dose reduces the risk to the patient,…
While filtered back projection (FBP) is still the method of choice for fast tomographic reconstruction, its performance degrades noticeably in the presence of noise, incomplete sampling, or non-standard scan geometries. We propose a…
We propose Noisier2Inverse, a correction-free self-supervised deep learning approach for general inverse problems. The proposed method learns a reconstruction function without the need for ground truth samples and is applicable in cases…
Deep learning (DL) has shown promise for faster, high quality accelerated MRI reconstruction. However, supervised DL methods depend on extensive amounts of fully-sampled (labeled) data and are sensitive to out-of-distribution (OOD) shifts,…
Computed tomography has propelled scientific advances in fields from biology to materials science. This technology allows for the elucidation of 3-dimensional internal structure by the attenuation of x-rays through an object at different…
Low-dose tomography is highly preferred in medical procedures for its reduced radiation risk when compared to standard-dose Computed Tomography (CT). However, the lower the intensity of X-rays, the higher the acquisition noise and hence the…
Ultrafast electron beam X-ray computed tomography produces noisy data due to short measurement times, causing reconstruction artifacts and limiting overall image quality. To counteract these issues, two self-supervised deep learning methods…
Noise is an important issue for radiographic and tomographic imaging techniques. It becomes particularly critical in applications where additional constraints force a strong reduction of the Signal-to-Noise Ratio (SNR) per image. These…
We propose a deep learning method for 3D volumetric reconstruction in low-dose helical cone-beam computed tomography. Prior machine learning approaches require reference reconstructions computed by another algorithm for training. In…
Self-supervised image denoising techniques emerged as convenient methods that allow training denoising models without requiring ground-truth noise-free data. Existing methods usually optimize loss metrics that are calculated from multiple…
In this paper, we present an algorithm for effectively reconstructing an object from a set of its tomographic projections without any knowledge of the viewing directions or any prior structural information, in the presence of pathological…
Electron tomographic reconstruction is a method for obtaining a three-dimensional image of a specimen with a series of two dimensional microscope images taken from different viewing angles. Filtered backprojection, one of the most popular…
X-ray computed tomographic infrastructures are medical imaging modalities that rely on the acquisition of rays crossing examined objects while measuring their intensity decrease. Physical measurements are post-processed by mathematical…
Hyperspectral neutron computed tomography enables 3D non-destructive imaging of the spectral characteristics of materials. In traditional hyperspectral reconstruction, the data for each neutron wavelength bin is reconstructed separately.…
This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may no longer be accessible. Computational imaging, especially non-line-of-sight (NLOS) imaging, the…
Hyperspectral neutron computed tomography is a tomographic imaging technique in which thousands of wavelength-specific neutron radiographs are measured for each tomographic view. In conventional hyperspectral reconstruction, data from each…
Sparse-view computed tomography (CT) enables fast and low-dose CT imaging, an essential feature for patient-save medical imaging and rapid non-destructive testing. In sparse-view CT, only a few projection views are acquired, causing…
Aiming at inferring 3D shapes from 2D images, 3D shape reconstruction has drawn huge attention from researchers in computer vision and deep learning communities. However, it is not practical to assume that 2D input images and their…