English
Related papers

Related papers: LEKID sensitivity for space applications between 8…

200 papers

Current generation millimeter wavelength detectors suffer from scaling limits imposed by complex cryogenic readout electronics. To circumvent this it is imperative to investigate technologies that intrinsically incorporate strong…

We present an analysis of the optical response of lumped-element kinetic-inductance detector arrays, based on the NIKA2 1mm array. This array has a dual-polarization sensitive Hilbert inductor for directly absorbing incident photons. We…

Instrumentation and Methods for Astrophysics · Physics 2018-09-27 Shibo Shu , Martino Calvo , Johannes Goupy , Andrea Catalano , Aurelien Bideaud , Alessandro Monfardini , Samuel Leclercq , Eduard F. C. Driessen

A low-energy electron diffraction (LEED) apparatus which works at temperatures down to about 100 mK is designed to obtain structural information of 2D helium on graphite. This very low temperature system can be realized by reducing the…

Materials Science · Physics 2015-06-11 K. Matsui , S. Nakamura , T. Matsui , Hiroshi Fukuyama

LiteBIRD, a forthcoming JAXA mission, aims to accurately study the microwave sky within the 40-400 GHz frequency range divided into 15 distinct nominal bands. The primary objective is to constrain the CMB inflationary signal, specifically…

The BULLKID-DM experiment aims to detect WIMP-like potential Dark Matter particles with masses below 1 GeV/c^2. Sensing these particles is challenging, as it requires nuclear recoil detectors characterized by high exposure and an energy…

Prototype of gamma ray detector based on Micro Pixel Avalanche Photodiodes (MAPD) with high pixel density 15000 pixel/$mm^2$, optically coupled to Lutetium Fine Silicate (LFS) scintillator has been developed. The detection performance…

Instrumentation and Detectors · Physics 2013-02-11 E. Guliyev , F. Ahmadov , G. Ahmadov , A. Sadigov , Z. Sadigov , N. Anfimov , Z. Krumshtein , A. Olshevski , V. Shvetsov , V. Zhezher , R. Madatov

The PRobe far-Infrared Mission for Astrophysics (PRIMA) is under study as a potential far-IR space mission, featuring actively cooled optics, and both imaging and spectroscopic instrumentation. To fully take advantage of the low background…

Microwave Kinetic Inductance Detectors (MKIDs) are superconducting detectors capable of counting single photons and measuring their energy in the UV, optical, and near-IR. MKIDs feature intrinsic frequency domain multiplexing (FDM) at…

Instrumentation and Methods for Astrophysics · Physics 2013-07-29 Sean McHugh , Benjamin A. Mazin , Bruno Serfass , Seth Meeker , Kieran O'Brien , Ran Duan , Rick Raffanti , Dan Werthimer

The main advantage of Microwave Kinetic Inductance Detector arrays (MKID) is their multiplexing capability, which allows for building cameras with a large number of pixels and good sensitivity, particularly suitable to perform large blank…

Instrumentation and Methods for Astrophysics · Physics 2016-09-02 L. Bisigello , S. J. C. Yates , L. Ferrari , J. J. A. Baselmans , A. M. Baryshev

In this study, the sensitivity of future lepton colliders to WIMP dark matter is evaluated assuming WIMP pair production accompanied by a photon from initial state radiation, through which the process can be identified. A full detector…

High Energy Physics - Experiment · Physics 2020-05-06 Moritz Habermehl , Mikael Berggren , Jenny List

Kinetic inductance detectors (KID) have great potential in astronomical observation, such as searching for exoplanets, because of their low noise, fast response and photon counting characteristics. In this paper, we present the design…

Instrumentation and Methods for Astrophysics · Physics 2022-09-21 Shiling Yu , Shibo Shu , Ran Duan , Lihui Yang , Di Li

We present a highly frequency multiplexed readout for large-format superconducting detector arrays intended for use in the next generation of balloon-borne and space-based sub-millimeter and far-infrared missions. We will demonstrate this…

LiteBIRD is a proposed JAXA satellite mission to measure the CMB B-mode polarization with unprecedented sensitivity ($\sigma_r\sim 0.001$). To achieve this goal, $4676$ state-of-the-art TES bolometers will observe the whole sky for 3 years…

Instrumentation and Methods for Astrophysics · Physics 2020-02-03 Tommaso Ghigna , Tomotake Matsumura , Masashi Hazumi , Samantha Lynn Stever , Yuki Sakurai , Nobuhiko Katayama , Aritoki Suzuki , Benjamin Westbrook , Adrian Lee

We present the operation with moderate radiation shield in a surface laboratory of BULLKID (BULky and Low-threshold Kinetic Inductance Detector), a cryogenic detector for searches of light Dark Matter or Coherent Elastic Neutrino-Nucleus…

We are developing superconducting Microwave Kinetic Inductance Detectors to operate at near infrared and optical wavelengths for astronomy. In order to efficiently meet with the requirements of astronomical applications, we propose to…

Instrumentation and Methods for Astrophysics · Physics 2019-01-30 S. Beldi , F. Boussaha , C. Chaumont , S. Mignot , F. Reix , A. Tartari , T. Vacelet , A. Traini , M. Piat , P. Bonifacio

We review advances in low temperature detector (LTD) arrays for Cosmic Microwave Background (CMB) polarization experiments, with a particular emphasis on imaging arrays. We briefly motivate the science case, which has spurred a large number…

A prototype of digital frequency multiplexing electronics allowing the real time monitoring of kinetic inductance detector (KIDs) arrays for mm-wave astronomy has been developed. It requires only 2 coaxial cables for instrumenting a large…

Instrumentation and Methods for Astrophysics · Physics 2015-03-18 O. Bourrion , A. Bideaud , A. Benoit , A. Cruciani , J. F. Macias-Perez , A. Monfardini , M. Roesch , L. Swenson , C. Vescovi

We present measurements and simulations of the polarization purity of leaky lens-antenna coupled microwave Kinetic Inductance Detectors (KIDs) at 1.5 THz. We find the integrated cross-polarization level to be at -21.5 dB for 1 f\#$\lambda$…

We present the development of a second generation digital readout system for photon counting microwave kinetic inductance detector (MKID) arrays operating in the optical and near-IR wavelength bands. Our system retains much of the core…

Microwave kinetic inductance detectors (MKIDs) are thin film, cryogenic, superconducting resonators. Incident Cooper pair-breaking radiation increases their kinetic inductance, thereby measurably lowering their resonant frequency. For a…

‹ Prev 1 4 5 6 7 8 10 Next ›