Related papers: XENON1T observes tritium
Efforts to identify dark matter by detecting nuclear recoils produced by dark matter particles reveal low-energy backgrounds of unknown origin in different types of detectors. In many cases, energy accumulation and delayed burst-like…
The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have…
The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be…
XENON is a novel liquid xenon experiment concept for a sensitive dark matter search using a 1-tonne active target, distributed in an array of ten independent time projection chambers. The design relies on the simultaneous detection of…
Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve…
We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on…
Several experimental techniques are currently under development, to measure the expected tiny fluxes of highest energy neutrinos above 10**18 eV. Projects in different stages of realisation are discussed here, which are based on optical and…
The recent observation of an excess in the electronic recoil data by the XENON1T detector has drawn many attentions as a potential hint for an extension of the Standard Model (SM). Absorption of a vector boson with the mass of…
An excess of events of unknown origin at low energies below 1 keV has been observed in multiple low-threshold dark matter detectors. Depending on the target material, nuclear recoil events at these energies may cause lattice defects, in…
Double beta decay is a very rare nuclear process and, therefore, experiments intended to detect it must be operated deep underground and in ultra-low background conditions. Long-lived radioisotopes produced by the previous exposure of…
The XENON collaboration recently reported an excess of electron recoil events in the low energy region with a significance of around $3.3\sigma$. An explanation of this excess in terms of thermal dark matter seems challenging. We propose a…
\Xe{136} is used as the target medium for many experiments searching for \bbnonu. Despite underground operation, cosmic muons that reach the laboratory can produce spallation neutrons causing activation of detector materials. A potential…
An unexpected feature of Titan's atmosphere is the strong depletion in primordial noble gases revealed by the Gas Chromatograph Mass Spectrometer aboard the Huygens probe during its descent on 2005 January 14. Although several plausible…
Announcement of detection of Solar 8B neutrinos by XENONnT dual-phase detector come with a suite of unexplained detector effects. We expect accumulation of surface charges and charged surface instability resulting in maximal surface…
We propose models of Dark Matter that account for the 511 keV photon emission from the Galactic Centre, compatibly with experimental constraints and theoretical consistency, and where the relic abundance is achieved via p-wave annihilations…
A brief review of particle physics motivations for axion existence is followed by a discussion of optical observables that can be used for axion detection. It is emphasised that the resonant photon - axion transition can occur in the…
Next-generation xenon detectors with multi-ton-year exposure are powerful direct probes of dark matter candidates, in particular the favorite weakly-interacting massive particles. Coupled with the features of low thresholds and backgrounds,…
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the…
Chang et al. (2006) reported millisecond duration dips in the X-ray intensity of Sco X-1 and attributed them to occultations of the source by small trans-Neptunian objects (TNOs). We have found evidence that these dips are in fact not…
We report results of a search for light (<10 GeV) particle dark matter with the XENON10 detector. The event trigger was sensitive to a single electron, with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear recoil…