English
Related papers

Related papers: Towards Sealed Resistive Plate Chambers

200 papers

This paper reports the latest developmental efforts for a position-sensitive glass-based Resistive Plate Chamber (RPC) and a multi-channel Data AcQuisition (DAQ) system tailored for muon tracking in muography applications. The designed…

Instrumentation and Detectors · Physics 2024-02-26 V. Kumar , S. Basnet , E. Cortina Gil , P. Demin , R. M. I. D. Gamage , A. Giammanco , R. Karnam , M. Moussawi , A. Samalan , M. Tytgat , A. Youssef

Due to their simplicity and comparatively low cost, Resistive Plate Chambers are gaseous detectors widely used in high-energy and cosmic rays physics, when large detection areas are needed. However, the best gaseous mixtures are currently…

Instrumentation and Detectors · Physics 2022-03-01 Livia Terlizzi

While in a triggered experiment the matching of the RPC transmission line impedance with the one of the front-end electronics is less critical, for a trigger-less data recording this becomes mandatory. As expected, impedance matching is not…

Instrumentation and Detectors · Physics 2017-08-10 D. Bartoş , M. Petriş , M. Petrovici , L. Rădulescu , V. Simion

Time Projection Chambers (TPCs) operated at high pressure have become a topic of interest for future long baseline neutrino experiments. Pressurized gas retains the low momentum threshold for particle detection of atmospheric TPCs, but…

Instrumentation and Detectors · Physics 2021-09-01 Philip Hamacher-Baumann , Stefan Roth , Thomas Radermacher , Nick Thamm

We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with…

In experiments searching for rare signals, background events from the detector itself are some of the major factors limiting search sensitivity.Screening for ultra-low radioactive detector materials is becoming ever more essential. We…

Instrumentation and Detectors · Physics 2021-12-24 Haiyan Du , Chengbo Du , Karl Giboni , Ke Han , Shengming He , Liqiang Liu , Yue Meng , Shaobo Wang , Tao Zhang , Li Zhao , Jifang Zhou

This paper presents a streamlined framework for real-time processing and analysis of condition data from the CMS experiment Resistive Plate Chambers (RPC). Leveraging data streaming, it uncovers correlations between RPC performance metrics,…

High Energy Physics - Experiment · Physics 2025-04-15 A. Dimitrov , M. Tytgat , K. Mota Amarilo , A. Samalan , K. Skovpen , G. A. Alves , E. Alves Coelho , F. Marujo da Silva , M. Barroso Ferreira Filho , E. M. Da Costa , D. De Jesus Damiao , S. Fonseca De Souza , R. Gomes De Souza , L. Mundim , H. Nogima , J. P. Pinheiro , A. Santoro , M. Thiel , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Shopova , G. Sultanov , L. Litov , B. Pavlov , P. Petkov , A. Petrov , E. Shumka , P. Cao , W. Diao , Q. Hou , H. Kou , Z. -A. Liu , J. Song , J. Zhao , S. J. Qian , C. Avila , D. A. Barbosa Trujillo , A. Cabrera , C. A. Florez , J. A. Reyes Vega , R. Aly , A. Radi , Y. Assran , I. Crotty , M. A. Mahmoud , M. Gouzevitch , G. Grenier , I. B. Laktineh , L. Mirabito , I. Bagaturia , I. Lomidze , Z. Tsamalaidze , V. Amoozegarp , B. Boghrati , M. Ebrahimi , F. Esfandi , Y. Hosseini , M. Mohammadi Najafabadi , E. Zareian , M. Abbrescia , N. De Filippis , G. Iaselli , F. Loddo , G. Pugliese , D. Ramos , L. Benussi , S. Bianco , S. Meola , D. Piccolo , S. Buontempo , F. Carnevali , F. Fienga , L. Lista , P. Paolucci , A. Braghieri , P. Montagna , C. Riccardi , P. Salvini , P. Vitulo , E. Asilar , T. J. Kim , Y. Ryou , S. Choi , B. Hong , K. S. Lee , J. Goh , J. Shin , Y. Lee , I. Pedraza , C. Uribe Estrada , H. Castilla-Valdez , R. Lopez-Fernandez , A. Sanchez Hernandez , M. Ramirez Garcia , D. L. Ramirez Guadarrama , M. A. Shah , E. Vazquez , N. Zaganidis , A. Ahmad , M. I. Asghar , H. R. Hoorani , S. Muhammad , J. Eysermans

Model predictive control of residential air conditioning could reduce energy costs and greenhouse gas emissions while maintaining or improving occupants' thermal comfort. However, most approaches to predictive air conditioning control…

Systems and Control · Electrical Eng. & Systems 2024-09-17 Elias N. Pergantis , Parveen Dhillon , Levi D. Reyes Premer , Alex H. Lee , Davide Ziviani , Kevin J. Kircher

Several high energy physics and neutrino physics experiments worldwide require large-size RPCs to cover wide acceptances. The muon tracking systems in the Iron calorimeter (ICAL) in the INO experiment, India and the near detector in DUNE at…

The India-based Neutrino Observatory (INO) collaboration is planning to build a massive 50kton magnetised Iron Calorimeter (ICAL) detector, to study atmospheric neutrinos and to make precision measurements of the parameters related to…

Instrumentation and Detectors · Physics 2019-08-13 Satyanarayana Bheesette

For precise start time determination a Beam Fragmentation T$_0$ Counter (BFTC) is under development for the Time-of-Flight Wall of the Compressed Baryonic Matter Spectrometer (CBM) at the Facility for Antiproton and Ion Research (FAIR) at…

We have developed multi-gap resistive plate chambers (MRPCs) with 2.5 x 200 cm2 readout strips for the time-of-flight (TOF) detector system of the LEPS2 experiment at SPring-8. These chambers consist of 2 stacks and 5 gas gaps per stack, in…

Time of flight of a minimum ionizing particle along a fixed base has been measured with a 100 ps accuracy by means of a Dielectric Resistive Plate Chamber (DRPC) with 4 x 0.3 mm gas gaps. DRPC timing characteristics have been studied with…

Instrumentation and Detectors · Physics 2007-05-23 A. Akindinov , V. Golovin , A. Martemiyanov , V. Petrov , V. Plotnikov , A. Smirnitsky , K. Voloshin

We present a new technology for the shaping of the electric field in Time Projection Chambers (TPCs) using a carbon-loaded polyimide foil. This technology allows for the minimisation of passive material near the active volume of the TPC and…

The limitation of the detection rate of standard bakelite resistive plate chambers (RPC) used as muon detectors in the LHC experiments has prevented the use of such detectors in the high rate regions in both CMS and ATLAS detectors. One…

Instrumentation and Detectors · Physics 2015-06-12 Y. Haddad , G. Grenier , I. Laktineh , N. Lumb , S. Cauwenbergh

A comparative study has been performed on Resistive Plate Chambers (RPC) made of two different grades of bakelite paper laminates, produced and commercially available in India. The chambers, operated in the streamer mode using argon,…

Instrumentation and Detectors · Physics 2010-11-30 S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , S. Saha , M. K. Sharan , Y. P. Viyogi

A novel concept for position-sensitive thermal neutron detectors based on thin-gap Resistive Plate Chambers (RPC) lined with a neutron converter layer is presented and its feasibility is discussed. Several detector architectures…

Instrumentation and Detectors · Physics 2018-08-29 L. M. S. Margato , A. Morozov

Driven by the recent improvement in additive manufacturing technologies, we designed a detector that can be fully printed with a standard and commercial 3D printer. The main goals of this research concern the marginal design and…

A new-concept time projection chamber (TPC) using a commercial resistive sheet, sheet-resistor micro-TPC SR-microPIC, was developed and its performance was measured. SR-microTPC has the potential to create a more uniform electric field than…

Resistive plate chamber (RPC) is one of the state-of-the-art particle detection technology for the High Energy Physics (HEP) experiments. The basic operating mechanism of an RPC involves ionization of gas due to the passage of charged…

Instrumentation and Detectors · Physics 2020-12-30 Tanay Dey , Supratik Mukhopadhyay , Subhasis Chattopadhyay , Jhilam Sadukan
‹ Prev 1 3 4 5 6 7 10 Next ›