Related papers: The GlueX Beamline and Detector
The CALICE collaboration is developing a granular electromagnetic calorimeter using (5-10) mm x 45 mm x 3 mm scintillator strips for a future linear collider experiment. Each scintillator strip is read out by using a Pixelated Photon…
A novel two-stage helium buffer gas cooled beam source is introduced. The properties of the molecular beams produced from this source are investigated theoretically using the CaF as a test molecule. The gas-phase molecules are first…
In order to fully reconstruct to the reaction e+e- to e+e- gamma-gamma in the energy region of the phi meson production, new detectors along the DAFNE beam line have to be installed in order to detect the scattered e+e-. The High Energy…
The ratio of the proton form factors, GEp/GMp, has been measured from Q2 of 0.5 GeV2 to 8.5 GeV2, at the Jefferson Laboratory, using the polarization transfer method. This ratio is extracted directly from the measured ratio of the…
A novel concept for producing polarized positrons at Jefferson Lab using the CEBAF polarized electron photo-injector is presented. This approach relies on the polarization transfer from low energy highly polarized electrons to positrons via…
Mathematical ambiguities in partial-wave analysis present a significant challenge to the extraction of resonance properties in hadronic reactions. Recent work has shown that while linear photon polarization can resolve continuous…
The photon flux resulting from high-energy electron beam interactions with high field systems, such as in the upcoming FACET-II experiments at SLAC National Accelerator Laboratory, may give deep insight into the electron beam's underlying…
In relativistic nuclear collisions some of the important aspects to be addressed are the effects of the nuclear PDF and the gluon saturation. In the LHC the best way to address these questions is by means of pA collisions and in particular…
We present a search for solar axions produced through the axion-electron coupling $(g_{ae})$ using data from a novel 7-GridPix detector installed at the CERN Axion Solar Telescope (CAST). The detector, featuring ultra-thin silicon nitride…
We measure for the first time the differential photoproduction cross section $d\sigma/dt$ of the $a_2(1320)$ meson at an average photon beam energy of 8.5~GeV, using data with an integrated luminosity of 104~pb$^{-1}$ collected by the GlueX…
The performance of hybrid GaAs pixel detectors as X-ray imaging sensors were investigated at room temperature. These hybrids consist of 300 mu-m thick GaAs pixel detectors, flip-chip bonded to a CMOS Single Photon Counting Chip (PCC). This…
We report on the first measurement of $J/\psi$ photoproduction from nuclei in the photon energy range of $7$ to $10.8$ GeV, extending above and below the photoproduction threshold in the free proton of $\sim8.2$ GeV. The experiment used a…
We present a combined experimental and theoretical study of beam formation from a cryogenic buffer gas cell. Atoms and molecules are loaded into the cell by laser ablation of a target, and are cooled and swept out of the cell by a flow of…
We present a strip transition-edge sensor microcalorimeter linear array detector developed for energy dispersive X-ray diffraction imaging and Compton scattering applications. The prototype detector is an array of 20 transition-edge-sensors…
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode,…
The non-linear energy response of the plastic scintillator EJ-260 is measured with the MicroCHANDLER detector, using neutron beams of energy 5 to 27 MeV at the Triangle Universities Nuclear Laboratory. The first and second order Birks'…
A calorimetric detector for minimally disruptive measurements of atomic hydrogen beams is described. The calorimeter measures heat released by the recombination of hydrogen atoms into molecules on a thin wire. As a demonstration, the…
The feasibility study of a new technique for thermal neutron detection using a Timepix3 camera (TPX3Cam) with custom-made optical add-ons operated in event-mode data acquisition is presented. The camera has a spatial resolution of ~ 16 um…
The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. A novel detector array…
The China Dark Matter Experiment (CDEX) is a low background experiment at China Jinping Underground Laboratory (CJPL) designed to directly detect dark matter with a high-purity Germanium (HPGe) detector. In the second phase CDEX-10 with a…