Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall…

Silicon Photomultipliers (SiPMs) are quickly replacing traditional photomultiplier tubes (PMTs) as the readout of choice for gamma-ray scintillation detectors in space. While they offer substantial size, weight and power saving, they have…

Instrumentation and Detectors · Physics 2021-02-03 Lee J. Mitchell , Bernard Phlips , W. Neil Johnson , Mary Johnson-Rambert , Anika N. Kansky , Richard Woolf

High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have…

Instrumentation and Detectors · Physics 2014-10-17 Paolo W. Cattaneo , Matteo De Gerone , Flavio Gatti , Miki Nishimura , Wataru Ootani , Massimo Rossella , Yusuke Uchiyama

Plastic scintillators are widely used in particle detectors when precise timing information is required. As a basis for comparing different detectors we use such a characteristic as the time resolution per 1MeV detected energy, i.e. the…

Instrumentation and Detectors · Physics 2021-09-08 Alexey Stoykov , Tigran Rostomyan

The detection of 200-1000 MeV neutrons requires large amounts, $\sim$100 cm, of detector material because of the long nuclear interaction length of these particles. In the example of the NeuLAND neutron time-of-flight detector at FAIR, this…

This article presents the development of a cost-effective and efficient electronic module for silicon photomultipliers (SiPM). The electronic module combines essential functionalities, such as a high voltage power supply, a preamplifier,…

Instrumentation and Detectors · Physics 2023-09-07 A. Sadigov , S. Nuruyev , R. Akbarov , D. B. Berikov , A. Madadzada , A. Mammadli

The matrices formed of silicon photomultipliers (SiPMs) are very promising photosensors for the scintillation detectors. The use of SiPM matrices with appropriate optical collector gives, in principle, a possibility to do a snapshot of…

Instrumentation and Methods for Astrophysics · Physics 2019-07-12 I. M. Dzaparova , A. M. Gangapshev , Yu. M. Gavrilyuk , V. B. Petkov , A. V. Sergeev , V. I. Volchenko , S. P. Yakimenko , A. F. Yanin

Using thin scintillating fibers with Silicon Photomultiplier (SiPM) readout a mo dular high-resolution charged-particle tracking detector has been designed. The fiber modules consist of 2 x 5 layers of 128 round multiclad scintillating…

Instrumentation and Detectors · Physics 2007-11-30 H. Gast , R. Greim , T. Kirn , G. Roper Yearwood , S. Schael

The combination of plastic scintillators with Silicon Photo-Multipliers (SiPMs) is widely used for detecting radiation in high-energy astrophysics, particle physics, neutrino physics, or medical physics. An example of application for this…

Instrumentation and Methods for Astrophysics · Physics 2025-02-14 Nicolas De Angelis , Franck Cadoux , Coralie Husi , Merlin Kole , Sławomir Mianowski

Silicon Photomultipliers (SiPM) represent a promising alternative to classical photomultipliers, for instance, for the detection of photons in high energy physics and medical physics. In the present work, electrical characterizations of…

Instrumentation and Detectors · Physics 2017-08-23 M. J. Boschini , C. Consolandi , P. G. Fallica , M. Gervasi , D. Grandi , M. Mazzillo , S. Pensotti , P. G. Rancoita , D. Sanfilippo , M. Tacconi , G. Valvo

The radiation damage to a silicon photomultiplier (SiPM) set on a satellite orbit increases energy threshold for scintillator detectors. We confirmed that 1 krad of radiation increases the energy threshold by approximately a factor of 10,…

Instrumentation and Detectors · Physics 2024-01-29 Teruaki Morishita , Yasushi Fukazawa , Hiromitsu Takahashi , Taishu Kayanoki , Ryota Niwa , Masaki Hashizume

In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active…

The performance of the $200\times2.5\times1$ cm$^3$ plastic scintillator strip with wavelength shifting fiber read-out by two novel photodetectors called Silicon PhotoMultipliers (SiPMs) is discussed. The advantages of SiPM relative to the…

Instrumentation and Detectors · Physics 2009-11-11 V. Balagura , M. Danilov , B. Dolgoshein , S. Klemin , R. Mizuk , P. Pakhlov , E. Popova , V. Rusinov , E. Tarkovsky , I. Tikhomirov

Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…

The analog hadron calorimeter for the International Linear Collider (ILC) of the CALICE collaboration utilized novel silicon detectors, the Sillicon Photomultipliers (SiPMs), for the detection of scintillation light coming from very small…

Instrumentation and Detectors · Physics 2012-11-28 Michal Tesař , Christian Jendrysik , Jelena Ninković , Frank Simon

We report on the possibility of using Silicon Photomultipliers (SiPMs) to detect the scintillation light from neutron conversion in ZnS:6LiF scintillators. The light is collected by wavelength-shifting fibers embedded into the scintillator.…

Instrumentation and Detectors · Physics 2015-06-18 A. Stoykov , J. -B. Mosset , U. Greuter , M. Hildebrandt , N. Schlumpf

Measured response functions and low photon yield spectra of silicon photomultipliers (SiPM) were compared to multi-photoelectron pulse-height distributions generated by a Monte Carlo model. Characteristic parameters for SiPM were derived.…

Nuclear Experiment · Physics 2008-11-26 S. Sanchez Majos , P. Achenbach , J. Pochodzalla

A novel modular high-resolution charged-particle tracking detector design using $250\mu m$ diameter, round, scintillating fibers and SiPM arrays for readout is presented. The fiber modules consist of 8 layers of 128 fibers, mechanically sta…

Instrumentation and Detectors · Physics 2008-11-26 Henning Gast , Thomas Kirn , Gregorio Roper Yearwood , Stefan Schael

Ahigh-granularity scintillator calorimeter readout with silicon photomultipliers (SiPMs) is an electromagnetic calorimeter (ECAL) candidate for experiments at the Circular Electron Positron Collider (CEPC). A critical design parameter of…

Instrumentation and Detectors · Physics 2021-12-22 Yazhou Niu

Photon readout of plastic scintillators is investigated with the aim of improving the precision of neutron \b{eta} decay experiments. Neutron decay is nowadays studied with high statistics, based on up to 109 registered decay events, and…

Instrumentation and Detectors · Physics 2021-06-08 Dirk Dubbers