During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense…

Instrumentation and Detectors · Physics 2015-01-21 T. Peltola

The Large Hadron Collider (LHC) at CERN will undergo major upgrades to increase the instantaneous luminosity up to 5-7.5$\times10^{34}$ cm$^{-2}$s$^{-1}$. This High Luminosity upgrade of the LHC (HL-LHC) will deliver a total of 3000-4000…

Instrumentation and Detectors · Physics 2023-03-08 The Tracker Group of the CMS Collaboration

The high pseudorapidity ($\eta$) region of the Compact Muon Solenoid (CMS) muon system is covered by Cathode Strip Chambers only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds…

Instrumentation and Detectors · Physics 2020-01-29 E. Voevodina , I. Crotty

At the High Luminosity LHC (HL-LHC), the CMS experiment will face a harsh environment with a high instantaneous luminosity up to 7x10$^{34}$/cm$^2$/s corresponding to an average of 140-200 multiple proton-proton collisions per bunch…

Instrumentation and Detectors · Physics 2018-12-04 Chang-Seong Moon

The present Compact Muon Solenoid silicon pixel tracking system has been designed for a peak luminosity of 1034cm-2s-1 and total dose corresponding to two years of the Large Hadron Collider (LHC) operation. With the steady increase of the…

Instrumentation and Detectors · Physics 2011-10-11 N. Parashar

Radiation damage significantly impacts the performance of silicon tracking detectors in Large Hadron Collider (LHC) experiments such as ATLAS and CMS, with signal reduction being the most critical effect; adjusting sensor bias voltage and…

High Energy Physics - Experiment · Physics 2025-01-22 Keerthi Nakkalil , Marco Bomben

The LHC machine at CERN finished its first year of pp collisions at a center of mass energy of 7 TeV. While the commissioning to exploit its full potential is still ongoing, there are plans to upgrade its components to reach instantaneous…

Instrumentation and Detectors · Physics 2011-03-22 Hans-Christian Kästli

The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large…

Instrumentation and Detectors · Physics 2023-07-19 E. Shumka , A. Samalan , M. Tytgat , M. El Sawy , G. A. Alves , F. Marujo , E. A. Coelho , E. M. Da Costa , H. Nogima , A. Santoro , S. Fonseca De Souza , D. De Jesus Damiao , M. Thiel , K. Mota Amarilo , M. Barroso Ferreira Filho , A. Aleksandrov , R. Hadjiiska , P. Iaydjiev , M. Rodozov , M. Shopova , G. Soultanov , A. Dimitrov , L. Litov , B. Pavlov , P. Petkov , A. Petrov , S. J. Qian , H. Kou , Z. -A. Liu , J. Zhao , J. Song , Q. Hou , W. Diao , P. Cao , C. Avila , D. Barbosa , A. Cabrera , A. Florez , J. Fraga , J. Reyes , Y. Assran , M. A. Mahmoud , Y. Mohammed , I. Crotty , I. Laktineh , G. Grenier , M. Gouzevitch , L. Mirabito , K. Shchablo , I. Bagaturia , I. Lomidze , Z. Tsamalaidze , V. Amoozegar , B. Boghrati , M. Ebraimi , M. Mohammadi Najafabadi , E. Zareian , M. Abbrescia , G. Iaselli , G. Pugliese , F. Loddo , N. De Filippis , R. Aly , D. Ramos , W. Elmetenawee , S. Leszki , I. Margjeka , D. Paesani , L. Benussi , S. Bianco , D. Piccolo , S. Meola , S. Buontempo , F. Carnevali , L. Lista , P. Paolucci , F. Fienga , A. Braghieri , P. Salvini , P. Montagna , C. Riccardi , P. Vitulo , E. Asilar , J. Choi , T. J. Kim , S. Y. Choi , B. Hong , K. S. Lee , H. Y. Oh , J. Goh , I. Yu , C. Uribe Estrada , I. Pedraza , H. Castilla-Valdez , A. Sanchez-Hernandez , R. L. Fernandez , M. Ramirez-Garcia , E. Vazquez , M. A. Shah , N. Zaganidis , A. Radi , H. Hoorani , S. Muhammad , A. Ahmad , I. Asghar , W. A. Khan , J. Eysermans , F. Torres Da Silva De Araujo

The current CMS silicon pixel detector as the innermost component of the CMS experiment is performing well at LHC design luminosity, but would be subject to severe inefficiencies at LHC peak luminosities of 2x10e34 cm^-2 s^-1. Therefore, an…

Instrumentation and Detectors · Physics 2015-05-15 Simon Spannagel

It is expected that the LHC accelerator and experiments will undergo a luminosity upgrade which will commence after several years of running. This part of the LHC operations is referred to as Super-LHC (SLHC) and is expected to provide…

Instrumentation and Detectors · Physics 2007-05-23 C. Foudas , A. Rose , J. Jones , G. Hall

A new Beam Halo Monitor (BHM) detector system has been installed in the CMS cavern to measure the machine-induced background (MIB) from the LHC. This background originates from interactions of the LHC beam halo with the final set of…

Instrumentation and Detectors · Physics 2019-08-13 Kelly Stifter

The planned upgrade of the LHC accelerator at CERN, namely the high luminosity (HL) phase of the LHC (HL-LHC foreseen for 2023), will result in a more intense radiation environment than the present tracking system was designed for. The…

Instrumentation and Detectors · Physics 2015-12-09 Timo Peltola

The HL-LHC will challenge the detectors with a nearly 10-fold increase in integrated luminosity compared to the previous LHC runs combined, thus the CMS detector will be upgraded to face the higher levels of radiation and the larger amounts…

Instrumentation and Detectors · Physics 2026-03-10 CMS HGCAL collaboration

We discuss a CMS eXtension for Studying Energetic Neutrinos (CMS-XSEN). Neutrinos at the LHC are abundant and have unique features: their energies reach out to the TeV range, and the contribution of the {\tau} flavour is sizeable. The…

Instrumentation and Detectors · Physics 2018-04-13 S. Buontempo , G. M. Dallavalle , G. De Lellis , D. Lazic , F. L. Navarria

Hadronic Forward(HF) detector is one of the sub-detectors of the CMS. It plays an important role in the measurement of forward jets and missing energy. HF is situated on both sides of the CMS interaction point, at about $\pm$11 m, covers…

Instrumentation and Detectors · Physics 2020-09-23 Yalcin Guler

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget…

Instrumentation and Detectors · Physics 2017-06-02 M. Dragicevic , M. Friedl , J. Hrubec , H. Steininger , A. Gädda , J. Härkönen , T. Lampén , P. Luukka , T. Peltola , E. Tuominen , E. Tuovinen , A. Winkler , P. Eerola , T. Tuuva , G. Baulieu , G. Boudoul , L. Caponetto , C. Combaret , D. Contardo , T. Dupasquier , G. Gallbit , N. Lumb , L. Mirabito , S. Perries , M. Vander Donckt , S. Viret , C. Bonnin , L. Charles , L. Gross , J. Hosselet , D. Tromson , L. Feld , W. Karpinski , K. Klein , M. Lipinski , G. Pierschel , M. Preuten , M. Rauch , M. Wlochal , M. Aldaya , C. Asawatangtrakuldee , K. Beernaert , D. Bertsche , C. Contreras-Campana , G. Eckerlin , D. Eckstein , T. Eichhorn , E. Gallo , J. Garay Garcia , K. Hansen , M. Haranko , A. Harb , J. Hauk , J. Keaveney , A. Kalogeropoulos , C. Kleinwort , W. Lohmann , R. Mankel , H. Maser , G. Mittag , C. Muhl , A. Mussgiller , D. Pitzl , O. Reichelt , M. Savitskyi , P. Schütze , V. Sola , S. Spannagel , R. Walsh , A. Zuber , H. Biskop , P. Buhmann , M. Centis-Vignali , E. Garutti , J. Haller , M. Hoffmann , R. Klanner , T. Lapsien , M. Matysek , A. Perieanu , Ch. Scharf , P. Schleper , A. Schmidt , J. Schwandt , J. Sonneveld , G. Steinbrück , B. Vormwald , J. Wellhausen , M. Abbas , C. Amstutz , T. Barvich , Ch. Barth , F. Boegelspacher , W. De Boer , E. Butz , M. Casele , F. Colombo , A. Dierlamm , B. Freund , F. Hartmann , S. Heindl , U. Husemann , A. Kornmeyer , S. Kudella , Th. Muller , H. J. Simonis , P. Steck , M. Weber , Th. Weiler , T. Kiss , F. Siklér , T. Tölyhi , V. Veszprémi , P. Cariola , D. Creanza , M. De Palma , G. De Robertis , L. Fiore , M. Franco , F. Loddo , G. Sala , L. Silvestris , G. Maggi , S. My , G. Selvaggi , S. Albergo , G. Cappello , S. Costa , A. Di Mattia , F. Giordano , R. Potenza , M. A. Saizu , A. Tricomi , C. Tuve , E. Focardi , M. E. Dinardo , S. Fiorendi , S. Gennai , S. Malvezzi , R. A. Manzoni , D. Menasce , L. Moroni , D. Pedrini , P. Azzi , N. Bacchetta , D. Bisello , M. Dall'Osso , N. Pozzobon , M. Tosi , L. Alunni Solestizi , M. Biasini , G. M. Bilei , C. Cecchi , B. Checcucci , D. Ciangottini , L. Fanò , C. Gentsos , M. Ionica , R. Leonardi , E. Manoni , G. Mantovani , S. Marconi , V. Mariani , M. Menichelli , A. Modak , A. Morozzi , F. Moscatelli , D. Passeri , P. Placidi , V. Postolache , A. Rossi , A. Saha , A. Santocchia , L. Storchi , D. Spiga , K. Androsov , P. Azzurri , G. Bagliesi , A. Basti , T. Boccali , L. Borrello , F. Bosi , R. Castaldi , M. Ceccanti , M. A. Ciocci , R. Dell'Orso , S. Donato , G. Fedi , A. Giassi , M. T. Grippo , F. Ligabue , G. Magazzu , P. Mammini , F. Mariani , E. Mazzoni , A. Messineo , A. Moggi , F. Morsani , F. Palla , F. Palmonari , A. Profeti , F. Raffaelli , A. Ragonesi , A. Rizzi , A. Soldani , P. Spagnolo , R. Tenchini , G. Tonelli , A. Venturi , P. G. Verdini , D. Abbaneo , I. Ahmed , E. Albert , G. Auzinger , G. Berruti , J. Bonnaud , J. Daguin , A. D'Auria , S. Detraz , O. Dondelewski , B. Engegaard , F. Faccio , N. Frank , K. Gill , A. Honma , A. Kornmayer , A. Labaza , F. Manolescu , I. McGill , S. Mersi , S. Michelis , A. Onnela , M. Ostrega , S. Pavis , A. Peisert , J. -F. Pernot , P. Petagna , H. Postema , K. Rapacz , C. Sigaud , P. Tropea , J. Troska , A. Tsirou , F. Vasey , B. Verlaat , P. Vichoudis , L. Zwalinski , F. Bachmair , R. Becker , D. di Calafiori , B. Casal , P. Berger , L. Djambazov , M. Donega , C. Grab , D. Hits , J. Hoss , G. Kasieczka , W. Lustermann , B. Mangano , M. Marionneau , P. Martinez Ruiz del Arbol , M. Masciovecchio , M. Meinhard , L. Perozzi , U. Roeser , A. Starodumov , V. Tavolaro , R. Wallny , D. Zhu , K. Bösiger , L. Caminada , F. Canelli , V. Chiochia , A. de Cosa , C. Galloni , T. Hreus , B. Kilminster , C. Lange , R. Maier , J. Ngadiuba , D. Pinna , P. Robmann , S. Taroni , Y. Yang , W. Bertl , K. Deiters , W. Erdmann , R. Horisberger , H. -C. Kaestli , D. Kotlinski , U. Langenegger , B. Meier , T. Rohe , S. Streuli , P. -H. Chen , C. Dietz , F. Fiori , U. Grundler , W. -S. Hou , R. -S. Lu , M. Moya , J. -F. Tsai , Y. M. Tzeng , D. Cussans , J. Goldstein , M. Grimes , D. Newbold , P. Hobson , I. D. Reid , G. Auzinger , R. Bainbridge , P. Dauncey , G. Hall , T. James , A. -M. Magnan , M. Pesaresi , D. M. Raymond , K. Uchida , T. Durkin , K. Harder , C. Shepherd-Themistocleous , M. Chertok , J. Conway , R. Conway , C. Flores , R. Lander , D. Pellett , F. Ricci-Tam , M. Squires , J. Thomson , R. Yohay , K. Burt , J. Ellison , G. Hanson , M. Olmedo , W. Si , B. R. Yates , A. Dominguez , R. Bartek , B. Bentele , J. P. Cumalat , W. T. Ford , F. Jensen , A. Johnson , M. Krohn , S. Leontsinis , T. Mulholland , K. Stenson , S. R. Wagner , A. Apresyan , G. Bolla , K. Burkett , J. N. Butler , A. Canepa , H. W. K. Cheung , D. Christian , W. E. Cooper , G. Deptuch , G. Derylo , C. Gingu , S. Grünendahl , S. Hasegawa , J. Hoff , J. Howell , M. Hrycyk , S. Jindariani , M. Johnson , F. Kahlid , S. Kwan , C. M. Lei , R. Lipton , R. Lopes De Sá , T. Liu , S. Los , M. Matulik , P. Merkel , S. Nahn , A. Prosser , R. Rivera , B. Schneider , G. Sellberg , A. Shenai , K. Siehl , L. Spiegel , N. Tran , L. Uplegger , E. Voirin , D. R. Berry , X. Chen , L. Ennesser , A. Evdokimov , C. E. Gerber , S. Makauda , C. Mills , I. D. Sandoval Gonzalez , J. Alimena , L. J. Antonelli , B. Francis , A. Hart , C. S. Hill , N. Parashar , J. Stupak , D. Bortoletto , M. Bubna , N. Hinton , M. Jones , D. H. Miller , X. Shi , P. Baringer , A. Bean , S. Khalil , A. Kropivnitskaya , D. Majumder , E. Schmitz , G. Wilson , A. Ivanov , R. Mendis , T. Mitchell , N. Skhirtladze , R. Taylor , I. Anderson , D. Fehling , A. Gritsan , P. Maksimovic , C. Martin , K. Nash , M. Osherson , M. Swartz , M. Xiao , J. G. Acosta , L. M. Cremaldi , S. Oliveros , L. Perera , D. Summers , K. Bloom , D. R. Claes , C. Fangmeier , R. Gonzalez Suarez , J. Monroy , J. Siado , E. Bartz , Y. Gershtein , E. Halkiadakis , S. Kyriacou , A. Lath , K. Nash , M. Osherson , S. Schnetzer , R. Stone , M. Walker , S. Malik , S. Norberg , J. E. Ramirez Vargas , M. Alyari , J. Dolen , A. Godshalk , C. Harrington , I. Iashvili , A. Kharchilava , D. Nguyen , A. Parker , S. Rappoccio , B. Roozbahani , J. Alexander , J. Chaves , J. Chu , S. Dittmer , K. McDermott , N. Mirman , A. Rinkevicius , A. Ryd , E. Salvati , L. Skinnari , L. Soffi , Z. Tao , J. Thom , J. Tucker , M. Zientek , B. Akgün , K. M. Ecklund , M. Kilpatrick , T. Nussbaum , J. Zabel , P. D'Angelo , W. Johns , K. Rose

The physics motivation, detector design, triggers, calibration, alignment, simulation, and overall performance of the very forward CASTOR calorimeter of the CMS experiment are reviewed. The CASTOR Cherenkov sampling calorimeter is located…

Instrumentation and Detectors · Physics 2021-02-11 CMS Collaboration

This paper has the purpose to study the rate capability of the Resistive Plate Chamber, RPC, starting from the basic physics of this detector. The effect of different working parameters determining the rate capability is analysed in detail,…

Instrumentation and Detectors · Physics 2016-08-03 G. Aielli , P. Camarri , R. Cardarelli , A. Di Ciaccio , L. Di Stante , R. Iuppa , B. Liberti , L. Paolozzi , E. Pastori , R. Santonico , M. Toppi

The CMS experiment will collect data from the proton-proton collisions delivered by the Large Hadron Collider (LHC) at a centre-of-mass energy up to 14 TeV. The CMS trigger system is designed to cope with unprecedented luminosities and LHC…

Instrumentation and Detectors · Physics 2009-05-07 Marta Felcini , Marco Zanetti

In the high luminosity scenario of the LHC (HL-LHC), which will bring the instantaneous luminosity up to 7.5\,$\times$\,$10^{34}$\,cm$^{-2}$s$^{-1}$, ATLAS and CMS will need to operate at up to 200 interactions per 25\,ns beam crossing and…

Instrumentation and Detectors · Physics 2021-06-11 Alessandro La Rosa