English
Related papers

Related papers: Herriott-cavity-assisted all-optical atomic vector…

200 papers

Atomic magnetometry is one of the most sensitive ways to measure magnetic fields. We present a method for converting a naturally scalar atomic magnetometer into a vector magnetometer by exploiting the polarization dependence of hyperfine…

Atomic Physics · Physics 2018-10-17 Tobias Thiele , Yiheng Lin , Mark O. Brown , Cindy A. Regal

We demonstrate a fast three-axis optical magnetometer using cold, optically-trapped $^{87}$Rb gas as a sensor. By near-resonant Faraday rotation we record the free-induction decay following optical pumping along two orthogonal axes to…

Accurate magnetic field direction sensing in compact platforms is critical in applications spanning magnetic navigation, space science, and biomedical imaging. We demonstrate a single-optical-axis vector optically pumped magnetometer based…

The atomic population trapped in uncoupled atomic states is a limiting factor for processes based on laser-atom interaction. The use of repump laser, bi-chromatic field, and vector magnetic field are explored in degenerate as well as…

Atomic Physics · Physics 2023-04-28 Swarupananda Pradhan , Sudip mandal

We experimentally demonstrate that a squeezed probe optical field can improve the sensitivity of the magnetic field measurements based on nonlinear magneto-optical rotation (NMOR) with an amplitude-modulated pump when compared to a coherent…

Quantum Physics · Physics 2023-07-19 Jiahui Li , Irina Novikova

We present a detailed spectroscopic investigation of a thermal $^{87}$Rb atomic vapour in magnetic fields up to 0.4T in the Voigt geometry. We fit experimental spectra with our theoretical model \textit{ElecSus} and find excellent…

Atomic Physics · Physics 2019-02-26 J. Keaveney , F. S. Ponciano-Ojeda , S. M. Rieche , M. J. Raine , D. P. Hampshire , I. G. Hughes

We use a $^{87}\text{Rb}$ atomic vapor, suitable for an optically-pumped magnetometer (OPM) in Earth-field conditions, to study the noise properties of three strategies for generating pulsed optical pumping. We compare a frequency-modulated…

It is clearly important to pursue atomic standards for quantities like electromagnetic fields, time, length and gravity. We have recently shown, using Rydberg states, that Rb atoms in a vapor cell can serve as a practical, compact standard…

Atomic Physics · Physics 2015-06-15 J. Sedlacek , A. Schwettmann , Harald Kübler , J. P. Shaffer

We describe the development of a simple atomic magnetometer using $^{87}$Rb vapor suitable for Earth magnetic field monitoring. The magnetometer is based on time-domain determination of the transient precession frequency of the atomic…

Atomic Physics · Physics 2015-06-05 L. Lenci , S. Barreiro , P. Valente , H. Failache , A. Lezama

We demonstrate an all-optical single beam pulsed atomic magnetometer assisted by laser mode-hopping in a distributed Bragg reflector (DBR) laser. We implement a temporal sequence of the laser current, with sinusoidal current modulation…

Atomic Physics · Physics 2025-01-14 Ji Hoon Yoon , Sang Hyuk Hong , Taek Jeong , Sin Hyuk Yim , Kyu Min Shim , Sangkyung Lee

A free-induction-decay (FID) type optically-pumped rubidium atomic magnetometer driven by a radio-frequency (RF) magnetic field is presented in this paper. Influences of parameters, such as the temperature of rubidium vapor cell, the power…

Atomic Physics · Physics 2023-01-23 Lulu Zhang , Yongbiao Yang , Ni Zhao , Jun He , Junmin Wang

We present a single-beam atomic magnetometer operating at room temperature for the measurement of ac magnetic fields. The magnetometer functions in the non-linear regime of magneto-optical rotation of $^{85}$Rb atomic vapour. We demonstrate…

Atomic Physics · Physics 2022-09-12 K. K. George Kurian , Sushree S. Sahoo , P. K. Madhu , G. Rajalakshmi

We present an experimental study of the intrinsic magnetometric sensitivity of an optical/rf-frequency double resonance magnetometer in which linearly polarized laser light is used in the optical pumping and detection processes. We show…

Atomic Physics · Physics 2009-11-13 G. Di Domenico , H. Saudan , G. Bison , P. Knowles , A. Weis

We describe and demonstrate how 3D magnetic field alignment can be inferred from single absorption images of an atomic cloud. While optically pumped magnetometers conventionally rely on temporal measurement of the Larmor precession of…

Optically pumped magnetometers are ultra-sensitive devices, but this sensitivity can significantly degrade due to heading errors, whereby a change in the angle between the pumping laser and the magnetic field translates to a change in the…

Applied Physics · Physics 2023-08-07 Yossi Rosenzweig , Dmitriy Tokar , Igor Shcerback , Menachem Givon , Ron Folman

We present a comprehensive numerical investigation into the radio frequency (RF) field behavior within miniaturized all-glass and hybrid vapor cell geometries designed for Rydberg atom-based electrometry. Using full-vector finite element…

We demonstrate the use of cylindrical vector beams - beams with spatially varying polarization - for detecting and preparing the spin of a warm rubidium vapor in a spatially dependent manner. We show that a modified probe vector beam can…

Atomic Physics · Physics 2015-06-03 Fredrik K. Fatemi

In this work we propose, and experimentally demonstrate, the use of a self-oscillating all-optical atomic magnetometer for magnetic induction measurements. Given the potential for miniaturization of atomic magnetometers, and their extreme…

Atomic Physics · Physics 2015-06-17 Arne Wickenbrock , François Tricot , Ferruccio Renzoni

An all-optical atomic magnetometer is used to detect a proton free-precession signal from a water sample polarized in a 0.7 T field and remotely analyzed in a 4 $\mu T$ field. Nuclear spins are manipulated either by $\pi/2$ pulses or by…

Atomic Physics · Physics 2015-05-13 Giuseppe Bevilacqua , Valerio Biancalana , Yordanka Dancheva , Luigi Moi

We present magnetic detection of a single, 2 {\mu}m diameter cobalt microparticle using an atomic magnetometer based on a microfabricated vapor cell. These results represent an improvement by a factor of 105 in terms of the detected…