Related papers: Loaded microwave cavity for compact vapor-cell clo…
We report on the performance of the first table-top prototype atomic clock based on coherent population trapping (CPT) resonances with parallel linearly polarized optical fields (lin||lin configuration). Our apparatus uses a vertical cavity…
We perform 3D finite element calculations of the fields in microwave cavities and analyze the distributed cavity phase errors of atomic clocks that they produce. The fields of cylindrical cavities are treated as an azimuthal Fourier series.…
Atomic clocks play a crucial role in timekeeping, communications, and navigation systems. Recent efforts enabled by heterogeneous MEMS integration have led to the commercial introduction of Chip-Scale Atomic Clocks (CSAC) with a volume of…
We demonstrated a compact 780 nm rubidium optical clock, which includes an optical frequency standard and an optical frequency comb, with an optical volume of 11.6 liters. Unlike the 778 nm rubidium atomic clocks based on two-photon…
We develop and demonstrate a compact (less than $6$ mL) portable Fabry-P\'{e}rot optical reference cavity. A laser locked to the cavity is thermal noise limited at $2\times10^{-14}$ fractional frequency stability. Broadband feedback control…
Optical atomic clocks have demonstrated revolutionary advances in precision timekeeping, but their applicability to the real world is critically dependent on whether such clocks can operate outside a laboratory setting. The challenge to…
Microfabricated alkali vapor cells are key to enable miniature devices such as atomic clocks and optically pumped magnetometers with reduced size, weight and power. Yet, more versatile fabrication methods are still needed to further expand…
Transportable all-optical atomic clocks represent the next-generation devices for precision time keeping, ushering a new era in encompassing a wide range of PNT (Positioning, Navigation and Timing) applications in the civil and strategic…
Hybrid quantum systems are highly promising platforms for addressing important challenges of quantum information science and quantum sensing. Their implementation, however, is technologically non-trivial, since each component typically has…
A piezoelectric voltage coupled microwave reentrant cavity has been developed. The central cavity post is bonded to a piezoelectric actuator allowing the voltage control of small post displacements over a high dynamic range. We show that…
We report on the realization of a new compact strontium optical clock using a 2-D magneto-optical-trap (2D-MOT) as cold atomic source and a multi-wavelength cavity as the frequency stabilization system. All needed optical frequencies are…
Since the pioneering work of Ramsey, atom interferometers are employed for precision metrology, in particular to measure time and to realize the second. In a classical interferometer, an ensemble of atoms is prepared in one of the two input…
Since the atomic clock was invented, its performance has been improved for one digit every decade until 90s of last century when the traditional atomic clock almost reached its limit. With laser cooled atoms, the performance can be further…
We present a new characterisation technique for atomic vapor cells, combining time-domain measurements with absorption imaging to obtain spatially resolved information on decay times, atomic diffusion and coherent dynamics. The technique is…
An analog crystal filter based cavity emulator is modified with reverse biased varactor diodes to provide a tuning range of around 160 Hz. The piezo drive voltage of the resonance controller is used to detune the cavity through the bias…
The coherent population trapping (CPT) atomic clock is very promising for use in next-generation spaceborne applications owing to its compactness and high performance. In this paper, we propose and implement a CPT atomic clock based on the…
Optical atomic clocks demonstrate a better stability and lower systematic uncertainty than the highest performance microwave atomic clocks. However, the best performing optical clocks have a large footprint in a laboratory environment and…
A novel open waveguide cavity resonator is presented for the combined variable frequency microwave curing of bumps, underfills and encapsulants, as well as the alignment of devices for fast flip-chip assembly, direct chip attach (DCA) or…
We report on a technique for applying a DC bias in a 3D microwave cavity. We achieve this by isolating the two halves of the cavity with a dielectric and directly using them as DC electrodes. As a proof of concept, we embed a variable…
Atomic devices such as atomic clocks and optically-pumped magnetometers rely on the interrogation of atoms contained in a cell whose inner content has to meet high standards of purity and accuracy. Glass-blowing techniques and craftsmanship…