Related papers: SND electromagnetic calorimeter time measurement a…
The cross section for the process e+e- --> omega pi0 --> pi0 pi0 gamma has been measured in the energy range 1.05--2.00 GeV. The experiment has been performed at the e+e- collider VEPP-2000 with the SND detector. The measured e+e- --> omega…
The Short-Baseline Near Detector (SBND) is one of three Liquid Argon Time Projection Chamber (LArTPC) neutrino detectors positioned along the axis of the Booster Neutrino Beam (BNB) at Fermilab, as part of the Short-Baseline Neutrino (SBN)…
We present measurements of the $E$-mode ($EE$) polarization power spectrum and temperature-$E$-mode ($TE$) cross-power spectrum of the cosmic microwave background using data collected by SPT-3G, the latest instrument installed on the South…
The fast development of superconducting nanowire single photon detector (SNSPD) in the past decade has enabled many advances in quantum information technology. The best system detection efficiency (SDE) record at 1550 nm wavelength was 93%…
The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of…
The operation and performance of the Compact Muon Solenoid (CMS) electromagnetic calorimeter (ECAL) are presented, based on data collected in pp collisions at $\sqrt{s}$ = 13 TeV at the CERN LHC, in the years from 2015 to 2018 (LHC Run 2),…
The process e+ e- -> phi -> K+ K- has been studied with the CMD-2 detector using about 542 000 events detected in the center-of-mass energy range from 1.01 to 1.034 GeV. The systematic error of the cross section is estimated to be 2.2%. The…
The cross section of the process $e^{+}e^{-}\rightarrow\eta\pi^{+}\pi^{-}$ is measured using the data collected with the CMD-$3$ detector at the VEPP-$2000$ collider in the center-of-mass energy range from $1.1$ to $2.0$ GeV. The decay mode…
The CALICE Semi-Digital Hadronic CALorimeter (SDHCAL) is the first technological prototype in a family of high-granularity calorimeters developed by the CALICE Collaboration to equip the experiments of future lepton colliders. The SDHCAL is…
The review of the SND results of the $e^+e^-\to\pi^+\pi^-\pi^0$ process study in the energy range $\sqrt[]{s}=0.42$ -- 1.38 GeV at VEPP-2M collider, based on about $2\times 10^6$ selected events, is presented. The total cross section,…
The cross section of the process e+e-\to\mu+\mu- was measured in the SND experiment at the VEPP-2M e+e- collider in the energy region \sqrt{s}=980, 1040 -- 1380 MeV. The event numbers of the process e+e-\to\mu+\mu- were normalized to the…
In the experiment to study the e+e->n+anti n process at the VEPP-2000 $e^+e^-$ collider, the ratio |GE|/|GM| of the neutron timelike electric and magnetic form factors has been measured. The experiment was carried out with the SND detector…
The first technological SDHCAL prototype having been successfully tested, a new phase of R&D, to validate completely the SDHCAL option for the International Linear Detector (ILD) project of the International Linear Collider (ILC), has…
A detailed investigation of hadronic interactions is performed using $\pi^-$-mesons with energies in the range 2--10 GeV incident on a high granularity silicon-tungsten electromagnetic calorimeter. The data were recorded at FNAL in 2008.…
Superconducting microcalorimeters, such as superconducting transition-edge sensors and magnetic microcalorimeters, have emerged as state-of-the-art detectors for X-ray emission spectroscopy by combining near-unity quantum efficiency with…
The Kitt Peak Electron Multiplying CCD (EMCCD) demonstrator is a new instrument that has been developed for use at the Kitt Peak National Observatory's 84-inch telescope. The EMCCD enables single-band optical imaging in the Sloan \textit{g}…
Calorimeters with silicon detectors have many unique features and are proposed for several world-leading experiments. We describe the R&D program of the large scale detector element with up to 12 000 readout channels for the International…
The FCAL collaboration is preparing large scale prototypes of special calorimeters to be used in the very forward region at a future linear electron positron collider for a precise and fast luminosity measurement and beam-tuning. These…
The purpose of the MIPP experiment is to study the inclusive production of photons, pions, kaons and nucleons in pi, K and p interactions on various targets using beams from the Main Injector at Fermilab. The function of the calorimeters is…
The process $e^+e^-\to K^+K^-\pi^0$ is studied with the SND detector at the VEPP-2000 $e^+e^-$ collider. Basing on data with an integrated luminosity of 26.4~pb$^{-1}$ we measure the $e^+e^-\to K^+K^-\pi^0$ cross section in the…