English
Related papers

Related papers: A Millimeter-scale Single Charged Particle Dosimet…

200 papers

We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eVee. We present results of…

Monolithic CMOS pixel detectors have emerged as competitive contenders in the field of high-energy particle physics detectors. By utilizing commercial processes they offer high-volume production of such detectors. A series of prototypes has…

We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which…

We report on the systematic study of a single-gas-electron-multiplication (GEM) loaded gaseous detector developed for precision measurements of high-energy particle beams and dose-verification measurements. In the present study, a…

Instrumentation and Detectors · Physics 2014-07-29 Kyong Sei Lee , Byungsik Hong , Sang Yeol Kim , Sung Keun Park

MiniCACTUS is a monolithic sensor prototype optimised for timing measurement of charged particles. It has been designed in a standard 150 nm CMOS process without dedicated amplification layer. It is intended as a demonstrator chip for…

Instrumentation and Detectors · Physics 2023-09-18 Yavuz Degerli , Fabrice Guilloux , Tomasz Hemperek , Jean-Pierre Meyer , Philippe Schwemling

A liquid isooctane (C$_{8}$H$_{18}$) filled ionization linear array for radiotherapy quality assurance has been designed, built and tested. The detector consists of 128 pixels, each of them with an area of 1.7 mm $\times$ 1.7 mm and a gap…

Medical Physics · Physics 2009-11-10 J. Pardo , L. Franco , F. Gomez , A. Iglesias , A. Pazos , J. Pena , R. Lobato , J. Mosquera , M. Pombar , J. Sendon

CMOS Monolithic Active Pixel Sensors (CPS) are ultra-light and highly granular silicon pixel detectors suited for highly sensitive charged particle tracking. Being manufactured with cost efficient standard CMOS processes, CPS may integrate…

Instrumentation and Detectors · Physics 2020-01-29 M. Deveaux

Active Pixel Sensor (APS) technology has shown promise for next-generation vertex detectors. This paper discusses the design and testing of two generations of APS chips. Both are arrays of 128 by 128 pixels, each 20 by 20 micro-m. Each…

Nuclear Experiment · Physics 2011-07-19 H. S. Matis , F. Bieser , S. Kleinfelder , G. Rai , F. Retiere , H. G. Ritter , K. Singh , S. E. Wurzel , H. Wieman , E. Yamamoto

We present measurements of radioactive contamination in the high-resistivity silicon charge-coupled devices (CCDs) used by the DAMIC experiment to search for dark matter particles. Novel analysis methods, which exploit the unique spatial…

FLASH radiotherapy necessitates the development of advanced Quality Assurance methods and detectors for accurate and online monitoring of the radiation field. This study introduces enhanced time-resolution detection systems and methods…

Diamond has been developed as a material for the detection of charged particles by ionization. Its radiation hardness makes it an attractive material for detectors operated in a harsh radiation environment e.g. close to a particle beam as…

Instrumentation and Detectors · Physics 2009-02-09 M. Mathes , M. Cristinziani , H. Kagan , S. Smith , W. Trischuk , J. Velthuis , N. Wermes

In beam test experiments have been carried out for particle identification using digital pulse shape analysis in a 500~$\mu$m thick Neutron Transmutation Doped (nTD) silicon detector with an indigenously developed FPGA based 12 bit…

Instrumentation and Detectors · Physics 2018-05-09 K. Mahata , A. Shrivastava , J. A. Gore , S. K. Pandit , V. V. Parkar , K. Ramachandran , A. Kumar , S. Gupta , P. Patale

External-cavity diode lasers are ubiquitous in atomic physics and a wide variety of other scientific disciplines, due to their excellent affordability, coherence length and versatility. However, for higher power applications, the…

Instrumentation and Detectors · Physics 2021-07-08 Andrew Daffurn , Rachel F. Offer , Aidan S. Arnold

Plastic scintillators detectors (PSDs) have been studied as dosimeters, since they provide a cost-effective alternative to conventional ionization chambers. Measurement and analysis of energy dependency were performed on a Siemens Mammomat…

Instrumentation and Detectors · Physics 2017-11-06 J. Antunes , J. Machado , L. Peralta , N. Matela

Surgical tumor resection aims to remove all cancer cells in the tumor margin and at centimeter-scale depths below the tissue surface. During surgery, microscopic clusters of disease are intraoperatively difficult to visualize and are often…

Image and Video Processing · Electrical Eng. & Systems 2025-12-17 Rahul Lall , Youngho Seo , Ali M. Niknejad , Mekhail Anwar

Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present…

We present an innovative charge detector with high resolution and wide dynamic range designed to fulfill the requirements of a monitoring system for a high energy ion beam. The detector prototype, constructed using Si photodiodes and a…

The widespread diffusion of precision radiotherapy techniques, geared toward the release of larger dose gradients in shorter time frames, is leading to new challenges in dosimetry. Accurate dose measurements are essential to check for beam…

Medical Physics · Physics 2022-05-17 S. Pettinato , M. Girolami , R. Olivieri , A. Stravato , C. Caruso , S. Salvatori

We present a 'digital SiPM' photo-detection chip combining single photon sensitive avalanche photo diodes and CMOS readout electronics on a single die. The chip has a size of $8046\times9032\,\mu m^2$ with $72.5\%$ of photo sensitive area.…

Instrumentation and Detectors · Physics 2025-01-27 Peter Fischer , Michael Keller , Michael Ritzert

In this paper the efficiency of direct charged particle detection with different Silicon PhotoMultiplier (SiPM) sensors has been measured to be close to 100%. Time resolution of about 20 ps has also been confirmed for sensors with an active…

‹ Prev 1 2 3 10 Next ›