Related papers: Improving the time resolution of the MRPC detector…
Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed…
The T2K ND280 upgrade aims to reduce the systematic uncertainty of the CP-violating phase, $\delta_{CP}$, to reject non-CP violation hypothesis at $3\sigma$ confidence level. A crucial component of the ND280 upgrade, alongside the Super…
The Belle II barrel region is instrumented with the Time of Propagation (TOP) particle identification system based on sixteen fused-silica bars arranged around the interaction point acting as Cherenkov radiator. Due to the mechanical design…
This study focuses on developing a self-triggered data acquisition system and a noise reduction algorithm for the Multi-gap Resistive Plate Chamber (MRPC) Time-of-Flight Positron Emission Tomography (TOF-PET) system. The system integrates a…
Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…
The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in technology for charged particle timing at high rates. In contrast to the role of timing for particle identification, which has…
A time-of-flight system with a plastic scintillator coupled to photomultipliers is developed for the external target facility (ETF). This system can satisfy the requirement of an ultrahigh vacuum ($\sim 10^{-9}$ mbar), a high counting rate…
State-of-the-art time-of-flight (ToF) based 3D sensors suffer from poor lateral and depth resolutions. In this work, we introduce a novel sensor concept that provides ToF-based 3D measurements of real world objects with depth precisions up…
In this work, the SLM-based phase retrieval system will be used to inspect carbon reinforced plastics samples (CFRP) under applying a thermal load. For this purpose, the system is used to capture a sequence of 8 spatially separated…
While recent camera-only 3D detection methods leverage multiple timesteps, the limited history they use significantly hampers the extent to which temporal fusion can improve object perception. Observing that existing works' fusion of…
Time-of-flight (ToF) imaging has become a widespread technique for depth estimation, allowing affordable off-the-shelf cameras to provide depth maps in real time. However, multipath interference (MPI) resulting from indirect illumination…
A new Digital Pulse Processing (DPP) system, based on domino ring sampler version 4 (DRS4), with good time resolution for the LaBr3 detectors has been developed and different digital timing analysis methods for processing the detector raw…
The use of Time Of Flight (TOF) in Positron Emission Tomography (PET) is expected to reduce noise on images, thanks to the additional information. In clinical routine, a common reconstruction approach is the use of maximum likelihood…
Indirect Time-of-Flight cameras (iToF) are low-cost devices that provide depth images at an interactive frame rate. However, they are affected by different error sources, with the spotlight taken by Multi-Path Interference (MPI), a key…
Time-of-flight magnetic resonance angiography (TOF-MRA) is one of the most widely used non-contrast MR imaging methods to visualize blood vessels, but due to the 3-D volume acquisition highly accelerated acquisition is necessary.…
During Phase-2 of the LHC, known as the High Luminosity LHC (HL-LHC), the accelerator will increase its instantaneous luminosity to 5 $\times$ 10$^{34}$ cm$^{-2}$ s$^{-1}$, delivering an integrated luminosity of 3000 fb$^{-1}$ over 10 years…
An optimized design of a neutron detector based on timing RPCs (Resistive Plate Chambers) with boron-10 neutron converters is presented. The detector is composed of a stack of ten double gap RPCs with aluminium cathode plates coated on both…
The detector of TRopIcal DEep-sea Neutrino Telescope (TRIDENT) will use large-area silicon photomultiplier (SiPM) arrays combined with photomultiplier tubes to boost photon detection efficiency and pointing capability. An…
Single-bed whole-body positron emission tomography based on resistive plate chamber detectors (RPC-PET) has been proposed for human studies, as a complementary resource to scintillator-based PET scanners. The purpose of this work is mainly…
The planned luminosity increase at the Large Hadron Collider in the coming years has triggered interest in the use of the particles' time of arrival as additional information in specialized detectors to mitigate the impact of pile-up. The…