Related papers: Absolute measurement of the Fano factor using a Sk…
We measure the absolute branching fractions of $\Ds$ semileptonic decays where the hadron in the final state is one of $\phi$, $\eta$, $\etap$, $\Ks$, $\Kstar$, and $f_0$, using $2.8 \times 10^5$ $\epm \to \Ds\Dsstar$ decays collected in…
This work briefly discusses the potential applications of the Skipper-CCD technology in astronomy and reviews its current use in dark matter and neutrino experiments. An overview of the ongoing efforts to build multi-kilogram experiments…
We study nonequilibrium transport through a charge Kondo device realizing the two-channel Kondo critical point in a recent experiment by Iftikhar et al. By computing the current and shot noise at low voltages near the critical point, we…
The Skipper-in-CMOS image sensor integrates the non-destructive readout capability of Skipper Charge Coupled Devices (Skipper-CCDs) with the high conversion gain of a pinned photodiode in a CMOS imaging process, while taking advantage of…
The \emph{MIDNA} application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that…
We present the first on-sky results from an ultra-low-readout-noise Skipper CCD focal plane prototype for the SOAR Integral Field Spectrograph (SIFS). The Skipper CCD focal plane consists of four 6k x 1k, 15 $\mu$m pixel, fully-depleted,…
We propose to search for millicharged particles produced in high-intensity electron beam dumps using small ultralow-threshold sensors. As a concrete example, we consider a Skipper-CCD placed behind the beam dump in Hall A at Jefferson Lab.…
The nature of charge carriers in strange metals has become a topic of intense current investigation. Recent shot noise measurements in the quantum critical heavy fermion metal YbRh$_2$Si$_2$ revealed a suppression of the Fano factor that…
We analyze the non-local shot noise in a multi-terminal junction formed by two Normal metal leads con- nected to one superconductor. Using the cross Fano factor and the shot noise, we calculate the efficiency of the Cooper pair splitting.…
We present the development of a Skipper Charge-Coupled Device (CCD) focal plane prototype for the SOAR Telescope Integral Field Spectrograph (SIFS). This mosaic focal plane consists of four 6k $\times$ 1k, 15 $\mu$m pixel Skipper CCDs…
Based on the detailed study of the scaling factor for $^{28}$\rm Si + $^{12}$\rm C charge-changing cross sections (CCCSs) at 90-1296 MeV/nucleon, we introduced a new approach to find the systematic energy dependence of the scaling factor…
For 4H silicon carbide (4H-SiC), the values for the electron-hole pair creation energy $\epsilon_{\text{i}}$ published in the literature vary significantly. This work presents an experimental determination of $\epsilon_{\text{i}}$ using…
We calculate the mode-dependent transmission probability of massless Dirac fermions through an ideal strip of graphene (length L, width W, no impurities or defects), to obtain the conductance and shot noise as a function of Fermi energy. We…
Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from…
We have carried out numerical simulations of shot noise in 2D arrays of single-electron islands with random background charges. The results show that in contrast with the 1D arrays, at low currents the current noise is strongly colored, and…
The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise…
We present a new instrument composed of a large number of sub-electron noise Skipper-CCDs operated with a two stage analog multiplexed readout scheme suitable for scaling to thousands of channels. New, thick, $1.35$ Mpix sensors, from a new…
This paper presents an absolute X-ray photon energy measurement method that uses a Bond diffractometer. The proposed system enables the prompt and rapid in-situ measurement of photon energies in a wide energy range. The diffractometer uses…
We report on an apparatus able to measure the absolute detection efficiency of a detector for electrons in the 30 - 900 eV range. In particular, we discuss the characterisation of a two-stage chevron microchannel plate (MCP). The…
The detection of weak forces is a central problem in physics and engineering, ranging in importance from fundamental pursuits such as precision tests of gravity, gravitational-wave detection, and searches for dark matter, to applications…